1.  IMPORTANT SAFETY INFORMATION

 

To  prevent  injury  to  the  user  or  other  people  and  property 
damage,  the  following  instructions  must  be  followed.  Incorrect 
operation  due  to  ignoring  of  instructions  may  cause  harm  or 
damage.

 

 

 

The safty  precautions listed here are divided into  two categories. In 
either case,  important safty information is listed which must  be read 
carefully.

 

 

 

                             

WARNING

 

              

 

Failure to observe a warning may result in death. The 
appliance shall be installed in accordance with national 
wiring regulations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure to observe a caution may result in injury or damage 
to the equipment.

 

 

 

 

Ask your dealer for installation of the air conditioner. 

Incomplete installation performed by yourself may result in a 
water leakage, electric shock, and fire.

 

 

Ask your dealer for improvement, repair, and 
maintenance.

 

Incomplete improvement, repair, and maintenance may result 
in a water leakage, electric shock, and fire.

 

Never touch the air outlet or the horizontal blades while 
the swing flap is in operation.

 

Fingers may become caught or the unit may break down.

 

 

Never put any objects into the air inlet or outlet.

 

Objects touching the fan at high speed can be dangerous.

 

 

Never inspect or service the unit by yourself.

 

Ask a qualified service person to perform this work.

 

 

Do not dispose this product as unsorted 
municipal waste. Collection of such waste 
separately for special treatment is necessary. 

Do not dispose of electrical appliances as unsorted 
municipal waste, use separate collection facilities.

 

 

Contact  you  local  government  for  information  regarding  the 
connection systems available.

 

 

If  electrical  appliances  are  disposed  of  in  landfills  or 
dumps,  hazardous  substances  can  leak  into  the 
groundeater  and  get  into  the  food  chain,  damaging  your 
health and well-being.

 

 

To prevent refrigerant leak, contact your dealer.

 

When  the  system  is  installed  and  runs  in  a  small  room,  it  is 
required to keep the concentration of the refrigerant, if by any 
chance coming out, below the limit. Otherwise, oxygen in the 
room may be affected, resulting in a serious accident.

 

 

The refrigerant in the air conditioner is safe and normally 
does not leak.

 

If  the  refrigerant  leaks  in  the  room,  contact  with  a  fire  of  a 
burner, a heater or a cooker may result in a harmful gas.

 

 

Turn  off  any  combustible  heating  devices,  ventilate  the 
room,  and  contact  the  dealer  where  you  purchased  the 
unit.

 

Do not use the air conditioner until a service person confirms 
that the portion where the refrigerant leaks is repaired.

 

 

If the  supply  cord is damaged,it must be replaced by the 
manufacturer,its  service  angent  or  similarly  qualified 
person in order to avoid a hazard.

 

 

 

 

 

CAUTION

 

In order to avoid electric shock, fire or injury, or if you 

  

 

detect any abnormality such as smell of fire, turn off the 
power supply and call your dealer for instructions.

 

 

Never let the indoor unit or the remote controller get wet.

 

It may cause an electric shock or a fire.

 

 

Never press the button of the remote controller with a 
hard, pointed object.

 

The remote controller may be damaged.

 

 

Never replace a fuse with that of wrong rated current or 
other wires when a fuse blows out.

 

Use of wire or copper wire may cause the unit to break down 
or cause a fire.

 

 

It is not good for your health to expose your body to the 
air flow for a long time.

 

 

Do not insert fingers, rods or other objects into the air 
inlet or outlet.

 

When the fan is rotating at high speed, it will cause injury.

 

 

Never use a flammable spray such as hair spray, 
lacqueror paint near the unit.

 

It may cause a fire.

 

Do not use the air conditioner for other purposes.

 

In order to avoid any quality deterioration, do not use the unit 
for cooling precision instruments, food, plants, animals or 
works of art.

 

 

Before cleaning, be sure to stop the operation, turn the 
breaker off or pull out the supply cord.

 

Otherwise, an electric shock and injury may result.

 

 

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

 

 

Be sure the air conditioner is grounded.

 

In order to avoid electric shock, make sure that the unit is 
grounded and that the earth wire is not connected to gas or 
water pipe, lightning conductor or telephone earth wire.

 

 

In order to avoid injury, do not remove the fan guard of 
the outdoor unit.

 

 

Do not operate the air conditioner with a wet hand.

 

An electric shock may happen.

 

 

Do not touch the heat exchanger fins.

 

These fins are sharp and could result in cutting injuries.

 

IMPORTANT SAFETY INFORMATION. ........................................ 1

 

OPERATION METHOD. ................................................................... 2

 

REINSTALLATION. ......................................................................... 4

 

MAINTENANCE. ...............................................................................5

 

CAUTION

 

WARNING

 

Содержание KMF-400 DN3

Страница 1: ... S MANUAL DC INVERTER FREE KMF 400 DN3 KMF 450 DN3 Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Страница 2: ......

Страница 3: ......

Страница 4: ...ll the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail Indoor unit Outdoor unit 1 Air outlet 2 Air inlet 3 Fixing support 4 Refrigerant pipe connector 5 Connection pipe ...

Страница 5: ...igerant leaks in the room contact with a fire of a burner a heater or a cooker may result in a harmful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired If the supply cord is damaged it must be replaced by the manu...

Страница 6: ...o not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out This appliance can be used by children age from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the a...

Страница 7: ... Total capacity of outdoor unit Reserve 6 5 Total requirement of indoor unit capacity Available for main unit 7 6 Total requirement of main unit corrected capacity Available for main unit 8 7 Operation mode 0 2 3 4 9 8 Thisoutdoorunitactualoperationcapacity Capacity requirement 10 9 Speed of fan A 0 1 9 10 11 10 Speed of fan B 0 1 9 10 12 11 T2B T2 average Temp Actual value 13 12 T3 T3A pipe Temp ...

Страница 8: ...tdoor unit and indoor unit will stop running 2 7 Heating capacity The heating operation is a heat pump process that heat will be absorbed from outdoor air and released in doors Once the outdoor temperature is decreased heating capacity decreased correspondingly Other heating equipment is suggested to be used together when outdoor temperature is too low In alpine region where the temperature is ext...

Страница 9: ...5 H7 Qty of indoor units decreases error Indoor unit lost for over 3 munites not recoverable until the unit qty recover 16 H9 3 times of P9 protection in 60 minutes Not recoverable until re power on 17 dF Defrosting 18 d0 Oil returning 19 P1 High pressure protection or discharge temperature switch protection 20 P2 Low pressure protection 21 xP3 Compressor current protection X represents in which s...

Страница 10: ...gularly to avoid super hot in the components 2 For detailed information about cleaning please refer to Indoor unit operation manual 4 5 Maintenance CAUTION After leaving unused for a long time inspect the air inlet and air outlet port of indoor and outdoor unit See if it has been blocked if it is blocked do cleaning immediately Before a long time idling please do the following work 1 Choose air su...

Страница 11: ...owner s manual 6 MD13U 024FW DZD 16127000A06218 ...