Do not operate the air conditioner with a wet hand.

 

An electric shock may happen. 

Do not touch the heat exchanger fins.

 

These fins are sharp and could result in cutting injuries. 

Do not place items which might be damaged by moisture 
under the indoor unit.

 

Condensation may form if the humidity is above 80%, the 
drain outlet is blocked or the filter is polluted. 

After a long use, check the unit stand and fitting for 
damage.

 

If damaged, the unit may fall and result in injury. 

To avoid oxygen deficiency, ventilate the room 
sufficiently if equipment with burner is used together 
with the air conditioner.

 

The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper tube.

 

5.Poor environmental conditions,  the appliance should be
maintained a month and a half or so; If the environment con- 
dition is good, may be extended appropriately maintenance
cycle.

The  air  conditioner  consists  of  the  indoor  unit,  the 
outdoor  unit,  the  connecting  pipe  and  the  remote 
controller.  

(see Fig.1)

 

Force Cooling Control

 

Force cooling 
control Button sw1 

Display control button sw2 

Arrange the drain hose to ensure smooth drainage. 

Incomplete drainage may cause wetting of the building, 
furniture etc. 

Never touch the internal parts of the controller.

 

Do not remove the front panel. Some parts inside are 
dangerous to touch, and a machine trouble may happen. 

Never expose little children, plants or animals directly to

 

Force Cooling Control

 

sw1   sw2 

MAIN BOARD 

(OUTDOOR UNIT)

 

F i g . 2 - 1

 

the air flow.

 

Adverse influence to little children, animals and plants may 
result. 

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

 

Falling or tumbling may result in injury. 

Do not operate the air conditioner when using a room 
fumigation - type insecticide.

 

Failure to observe could cause the chemicals to become 
deposited in the unit, which could endanger the health of 
those who are hypersensitive to chemicals. 

Force  cooling  control  of  outdoor  unit  be  pressed  once  that  a  order 
to  force  cooling  in  indoor  unit.  When  the  frequency  of  outdoor  unit 
change  to  62Hz  and  then  running  it;  indoor  fan  run  in  high  speed. 
Press  the  button  again  will  exit  the  Force  Cooling  Control. 

Display function

 

SW2  on the main  control  board  of outdoor  unit  is the  point 
inspection  function  button  (as  shown  in Figure  2-1).  Pressing  this 
button  once  displays  the  first  parameter  of the  digital  pipe  in  the 
main  control  board. 
Additional  button  presses  will  display  other  parameters  following 
the sequence  shown  in Table  2-1. 

Table 2-1 

Do not place appliances which produce open fire in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It may cause incomplete combustion or deformation of the unit 
due to the heat. 

Do not install the air conditioner at any place where 
flammable gas may leak out.

 

If the gas leaks out and stays around the air conditioner, a fire 
may break out. 

This appliance can be used by children age from 8 years 
and above and persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge

 

if they have been given supervision or instruction

 

concerning use of the appliance in a safe way and 
understand the hazards involved, children should not play 
with This appliance. Cleaning and user maintenance 
should not  be made by children without supervision.

 

When capacity of indoor unit greater than the sum of

 

100%, capacity of indoor unit will be attenuated.

 

When capacity of indoor unit greater than or equal to the 
sum of 120%, in order to ensure the effectiveness of 
machine, and then try to open the indoor units at 
different time.

 

The outdoor unit window-shades should be periodic 
cleaning in case of being jammed.

 

This window-shapes is heat dissipation outlet of components, if being 
jammed will cause the components shorten their service life spans because 
of overheated for a long time. 

Sequence 

Displayed Content 

0-- 

1-- 

2-- 

3-- 

4-- 

5-- 

6-- 

7-- 

8-- 

10 

9-- 

11 

0-- 

12 

1-- 

13 

2-- 

14 

3-- 

15 

4-- 

16 

5-- 

17 

6-- 

18 

7-- 

19 

8-- 

20 

9-- 

Normal display

 

Current frequency 
Local capacity of outdoor units 
Total capacity requirements of outdoor 
units 

Total  requirements of  outdoor units 
corrected capacity 

Operating mode 

Operating FAN speed and FAN grade 

T2B/T2 average temperature 
T3 pipe temperature 
T4 environment temperature 
Inverter exhaust temperature 

Non-inverter exhaust temperature 

(reserved) 

Heat dissipater surface temperature 

(reserved) 

Electronic expansion valve aperture 

Inverter input current 

Non-inverter input current 
Exhaust pressure (reserved) 

Priority mode 
Indoor unit quantity 
Working indoor unit quantity 
Last fault or protection code 

-- 

owner's manual 

Содержание KMF-200 DN2

Страница 1: ...UAL DC INVERTER FREE KMF 200 DN2 KMF 224 DN2 KMF 260 DN2 Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for futu...

Страница 2: ...tdoor unit 1 4 1 Air outlet 3 2 Air inlet 3 Fixing support 4 Refrigerant pipe connector Fig 1 5 Connection pipe NOTE All the pictures in this manual are for explanation purpose only They may be slight...

Страница 3: ...ur dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the limit Otherwise oxygen in the room may...

Страница 4: ...function SW2 on the main control board of outdoor unit is the point inspection function button as shown in Figure 2 1 Pressing this button once displays the first parameter of the digital pipe in the...

Страница 5: ...a minimum the installation must have a demand of 20 of the capacity of the outdoor unit in the models less than 40kW or a demand of 10 of the capacity in the models of a capacity greater than or equal...

Страница 6: ...lt 11 Voltage protection fault or a lack of Phase B Phase N 12 DC fan motor fault 13 Discharge temperature sensor fault 14 A fan in the A region run for more than 5 minutes in heat mode 15 2 times of...

Страница 7: ...to the unit Symptom 6 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 7 The outdoor unit fan does not spin During operation...

Страница 8: ...tdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Out...

Страница 9: ...ted on the display is FAN ONLY The temperature cannot be set during FAN mode The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when th...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: