General Technical
Size
190S
300S
Power and Efficiency
Tout 15/12°C ( DB/WB),
Tw,in 15 °C
Tw,out 45°C
Thermal power
kW
1,62
2,30
Total power absorbed
kW
0,42
0,53
COP
3,86
4,34
Thermal power
kW
2,31
3,25
Tout 43/26°C ( DB/WB),
Tw,out 70°C -->
190S
Tw,out 65°C -->
300S
Total power absorbed
kW
0,546
0,627
COP
4,23
5,18
Electric heating element
kW
3,00
3,00
Standard power supply
V
220-240/1/50
Heating time DHW
(1)
h/min
3/53
4/22
Minimum temperature DHW
°C
7
7
Maximum temperature DHW
(6)
°C
70
70
Sound pressure level (1m)
(5) dB(A)
36,6
38,2
Sound power level (L
WA
)
dB(A)
51
53
ErP
Clima Average
Heat pumps Water Heater
(2)
Energy class of generator
A+
A+
Domestic hot water profile
L
XL
η
wh
%
115
123
Annual consumption AEC
kWh
890
1356
Daily consumption
kWh
4,22
6,34
COP EN 16147
2,76
3,01
Clima Warmer
Heat pumps Water Heater
(3)
Domestic hot water profile
L
XL
η
wh
%
125
143
Annual consumption AEC
kWh
819
1173
Daily consumption
kWh
3,86
5,49
COP EN 16147
3,13
3,59
Clima Colder
Heat pumps Water Heater
(4)
Domestic hot water profile
L
XL
η
wh
%
99
91
Annual consumption AEC
kWh
1034
1845
Daily consumption
kWh
4,90
8,56
COP EN 16147
2,36
2,32
Domestic Hot Water Accumulator
Volume of Domestic hot water Accumulator
l
168
272
Maximum operating pressure
bar
10
10
MPa
1
1
Material of accumulator tank
Enamel Steel
Insulation Material
Polyurethane foam
Insulation Thickness
mm
50
50
Refrigerant Circuit
Compressor type
Rotary
Rotary
Refrigerant Gas
R134-a
R134-a
Quantity of refrigerant
kg
1,10
1,40
GWP
t
1430
1430
Tonne of CO2 equivalents
t
CO2
1,57
2,00
Oil quantity
ml
350
350
Type of expansion valve
Electronic
Electronic
13 TECHNICAL DATA