
56
12.4
t_DRYUP
The day for w arming up during floor drying up
8
4
15
1
DAY
12.5
t_HIGHPEAK
The continue days in high temperature during floor
drying up
5
3
7
1
DAY
12.6
t_DRYD
The day of dropping temperature during floor drying
up
5
4
15
1
DAY
12.7
T_DRYPEAK
The target peak temperature of w ater flow during
floor drying up
45
30
55
1
°C
12.8
START TIME
The start time of floor drying up
Hour
:
the
present
time(not on
the hour +1,
on the hour
+2)
Minute:00
0:00
23:30
1/30
h/min
12.9
START DATE
The start date of floor drying up
The present
date
1/1/2000
31/12/2099
1/1/2001
d/m/y
13.1
AUTO RESTART
COOL/HEAT MODE
Enable or disable the auto restart cooloing/heating
mode. 0=NON,1=YES
1
0
1
1
/
13.2
AUTO RESTART DHW
MODE
Enable or disable the auto restart DHW mode.
0=NON,1=YES
1
0
1
1
/
14.1
POWER INPUT LIMITATION The type of pow er input limitation, 0=NON,
1~8=TYPE 1~8
0
0
8
1
/
15.1
ON/OFF
(
M1 M2
)
Define the function of the M1M2 sw itch;
0= REMOTE ON/OFF,1= TBH ON/OFF,2= AHS ON/OFF
0
0
2
1
/
15.2
SMART GRID
Enable or disable the SMART GRID;
0=NON,1=YES
0
0
1
1
/
15.3
T1b
(
Tw 2
)
Enable or disable the T1b(Tw 2) ;
0=NON,1=YES
0
0
1
1
/
15.4
Tbt1
Enable or disable the Tbt1;
0=NON,1=YES
0
0
1
1
/
15.5
Tbt2
Enable or disable the Tbt2;
0=NON,1=YES
0
0
1
1
/
15.6
Ta
Enable or disable the Ta;
0=NON,1=YES
0
0
1
1
/
15.8
15.9
<
10m,1=F-PIPE LENGTH
≥
10m
15.10
15.11
0=NON,1=YES
16.1
16.2
TIME_ADJUST
16.3
17.1
17.2
SOLAR INPUT
Choose the SOLAR INPUT;
0=NON,1=CN18Tsolar,2=CN11SL1SL2
0
0
2
1
/
F-PIPE LENGTH
Choose the total length of the liquid pipe(F-PIPE
LENGTH);
0=F-PIPE LENGTH
0
0
1
1
/
0
0
1
1
/
RT/Ta_PCB
Enable or disable the RT/Ta_PCB;
0
0
1
1
/
PER_START
Start-up percentage of multiple units
10
10
100
10
%
Adjustment time of adding and subtracting units
5
1
60
1
MIN
ADDRESS RESET
Reset the address code of the unit
FF
0
15
1
/
HMI SET
Choose the HMI;
0=MASTER,1=SLAVE
0
0
1
1
/
HMI ADDRESS FOR BMS Set the HMI address code for BMS
1
1
16
1
/
15.7
Ta-adj
The corrected value of Ta on wired controller
-2
-10
10
1
℃
PUMPI SILENT MODE
Enable or disable PUMPI SILENT MODE
0=NON, 1=YES