49
Go to MENU> FOR S ERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
10.7.8 HOLIDAY AWAY SETTING
Press
▼
▲
to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input
■
,
as shown below:
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn’t
work properly, call this number for help.
10.7.9 SERVICE CALL SETTING
ADJUST
OK
CONFIRM
20°C
20°C
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
9 SERVICE CALL SETTING
PHONE NO. 0000000000000
MOBILE NO. 0000000000000
ROOM THERMOSTAT = NON, no room thermo-
stat.
ROOM THERMOSTAT = MODE SET, the wiring of
room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the wiring
of room thermostat should follow method C (refer to
9.7.6 "Connection for other components/For room
thermostat")
NOTE
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources and solar energy kit.
10.7.7 Other HEATING SOURCE
30MIN
-5°C
5°C
30MIN
5°C
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
1/2
The RESTORE FACTORY SETTING is used to restore
all the parameters set in the user interface to the factory
setting.
10.7.10 RESTORE FACTORY SETTINGS
TEST RUN is used to check correct operation of the
valves, air purge, circulation pump operation, cooling,
heating and domestic water heating.
10.7.11 TEST RUN
Go to MENU> FOR SERVICEMAN> 10.RESTORE
FACTORY SETTINGS. Press OK. The following page will
be displayed:
Press
▼
▲
to scroll the cursor to YES and press OK. The
following page will be displayed:
After a few seconds, all the parameters set in the user
interface will be restored to factory settings.
10 RESTORE FACTORY SETTINGS
All the settings will come back to
factory default.
Do you want to restore factory
settings?
OK
CONFIRM
NO
YES
Please wait…
5%
10 RESTORE FACTORY SETTINGS
The number displayed on the user interface is the phone
number of your local dealer.
-5
°C
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE PIPE LOOP
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
2/2
0.0kW
0.0kW
2.0kW
ADJUST
OK
CONFIRM
9 SERVICE CALL
PHONE NO. ***************
MOBILE NO. ******************