Page 38
Wiring
Field wiring
1. Overview
2. Interface Description
Weak load interface
MAIN BOARD
CN80
CN5
PUMP
M
3
CN600
JR400
T
W
1
CN201
CN40
WIRE
CONTROLLER
4
RY2
3
RY4
3
TO OUTDOOR UNIT
N(A)
L(A)
S(A)
N
L
CN3
CN10 CN12
CN1 CN2 CN300
HEATER
THERMOSTAT
Y/G
Y/G
CN13
CN11
BLUE
BLUE
YELLOW
YELLOW
Y/G
Y/G
RED
RED
BLACK
BLACK
RED
YELLOW
T
R
_I
T
R
_O
T
W
_I
T
W
_O
CN200
D
C
B
A
POWER
Y/G
CN202
CN203
CN204
CN400
ON-OFF
R
E
M
O
T
E
C
O
N
T
R
O
L
2
Pumpo PumpT S
V
2
AHS K_heater2
SV3_1 COM SV3_2 COM
CN7
CN8
CN9
FLOW SWITCH
TH
Tk
TW1B
NOTE:
Remove the short connector
of JR400 when you use the
"ON-OFF" function.
M
M
4
WIFI MODULE
4
FUSE
RED
AC CONTACTOR
CODE
PART NAME
TW_O
TEMPERATURE SENSOR FOR EXCHANGER OUTLET WATER
TW_I
TEMPERATURE SENSOR FOR EXCHANGER INLET WATER
TR_O
TEMPERATURE SENSOR FOR REFRIGERANT GAS
TR_I
TEMPERATURE SENSOR FOR REFRIGERANT LIQUID
TW1
TEMPERATURE SENSOR FOR OUTLET WATER OF HYDRAULIC MODULE
Tk
TEMPERATURE SENSOR FOR WATER OF WATER TANK
TH
TEMPERATURE SENSOR FOR RETURN WATER
TW1B
TEMPERATURE SENSOR FOR TOTAL OUTLET WATER
Sv2
2-WAY VALVE
Sv3_1,SV3_2 3-WAY VALVE
AHS
CONTROL SIGNAL OF ASSISTANT HEAT SOURCE
Pumpo
PUMP
PumpT
PUMP FOR RETURN WATER/PUMP FOR MIXING WATER
K_heater2
CONTROL SIGNAL OF WATER TANK HEATER
RY2,RY4
RELAY
Содержание KHHP-BI