1
2
3
4
5
6
9
7
8
10
11
12
13
14
15
TW1_In
TW_Out
TW1
TR_In
TR_Out
Page 24
1. Outdoor unit
2. Indoor unit
3. Refrigerant to water heat exchanger
4. Manometer
5. Pump
6. Shut-off valve
7. Filter
8. Auto-water replenishing
9. Shut-off valve
10. Flow switch
11. Auxiliary heater vessel
(Separate power supply)
12. Pressure relieve valve
13. Automatic air purge valve
14. Drain valve
15. Expansion vessel
Unit Parts
Functional diagram
1. Outdoor unit
2. Indoor unit
3. Refrigerant to water heat exchanger
4. Auxiliary heater vessel
5. Pump
6. The wire controller
7. Globe valve(field supply)
8. External circulating water pump
( field supply)
9. Floor heating
10. Electric three-way valve (field supply)
11. Domestic hot water storage tank
12. Heating coil
13. Electric immersion heater
14. Temperature probe tube
15. Anode magnesium rod
16. Sewage outlet
17. Electric two-way valve
19. Backwater pump
20. Return water temperature sensing bag
21. Mixing water pump
22. Mixing valve
23. Radiator
24. Heating water supply main pipe temperature
sensing package
25. Pipeline auxiliary electric heating
26. Auxiliary heat source
27. Check valve
28. Water separator
29. Electric actuator
31. External signal interface
32. Filter (Water supply system)
33. Differential pressure make-up valve
34. Differential pressure bypass valve
F
Содержание KHHP-BI
Страница 45: ......