5.3.1 Moving and installation
Since the gravity center of the unit is not at its physical
center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45°, and do not lay it sidelong.
Make concrete foundation according to the specifications of
the outdoor units.
Fasten the feet of this unit with bolts firmly to prevent it
from collapsing in case of earthquake or strong wind.
0
0
6
>
Fix with bolt
NOTE
All the pictures in this manual are for explanation purpose only.
They may be slightly different from the air conditioner you
purchased (depend on model). The actual shape shall prevail.
5.3.2 Water Outlet
The condensed water outlets on the chassis for selection
display as the follow figure:
5/7kW
Water Outlet
10~16kW
Reserve water outlet
(Need to knock open)
Reserve water outlet
Water Outlet
(With rubber stopper)
CAUTION
While installing the outdoor unit, pay attention to the
installation place and the drainage pattern;
If it’s installed at the alpine zone, the frozen condensed water will
block up the water outlet, please pull out the rubber stopper of the
reserve water outlet (10~16kW). If that still fails to satisfy for the
water draining, please knock open the other water outlets
(10~16kW), and keep the water can drain in time.
Pay attention to the knock the reserve water outlet from outside to
inside, and it will be beyond repair after knocking open, please pay
attention to the installation place, lest cause the inconvenience.
Please do the moth proofing for the knocked-out hole, to avoid
the pest processing into and destroy the components.