■ To prevent exposure to wind, install the unit with its suction side
facing the wall.
■ Never install the unit at a site where the suction side may be
exposed directly to wind.
■ To prevent exposure to wind, install a baffle plate on the air
discharge side of the unit.
■ In heavy snowfall areas it is very important to select an installation
site where the snow will not affect the unit. If lateral snowfall is
possible, make sure that the heat exchanger coil is not affected by
the snow (if necessary construct a lateral canopy).
H
A
G
1 Construct a large canopy.
2 Construct a pedestal.
Install the unit high enough off the ground
to prevent it from being buried in snow.
5.2.2 Selecting a location in hot climates
As the outdoor temperature is measured via the outdoor unit air
thermistor, make sure to install the outdoor unit in the shade, or a
canopy should be constructed to avoid direct sunlight. so that it is
not influenced by the sun’s heat, otherwise protection may be
possible to the unit.
5.3 Installation space (Unit:mm)
H
A
G
B
C
D
E
F
MODEL
A
B
C
D
E
F
G
H
(kW)
5/7
994
626
382
342
363
396
1008
963
B
E
F
C
D
MODEL
A
B
C
D
E
F
G
H
(kW)
10/12
900
600
348
320
360
400
970
1327
/14/16
Single unit installation
(Wall or obstacle)
>300
Air inlet
>
300
Maintain
cha
nnel
Air inlet
>600
2000
Air outlet
>
Parallel connect the two units or above
>300
>600
>2000
Parallel connect the front with rear sides
>2000
>500
>3000
>3000
>300
12