Kaysun KC-03.1 SPS Скачать руководство пользователя страница 15

15 

Child lock function 

Keypad tone setting 

Press 

Lock 

button for 3 seconds to activate the lock 

function and lock all buttons on the wire controller. 
Press the button again for 3 seconds to deactivate the lock 
function. 

When the lock function is active, the mark 

 

appears 

Press buttons 

Swing 

and 

Timer 

simultaneously for 3 

seconds to turn off the keypad tone. 

Press the buttons again for 3 seconds to turn on the 
keypad tone. 

ºC and ºF scale selection (on some models) 

Press the buttons 

Back 

and 

Copy 

simultaneously for 3 

seconds will alternate the temperature display between 
ºC and ºF. 

Turbo Function (on some models) 

Press 

Turbo 

button to activate the turbo function. 

Press button again to deactivate the turbo function. 

When the turbo function is activated, the mark 
appears 

Faceplate function (on some models) 

When the unit is off, press 

Mode 

button long to activate the 

faceplate function. 

The mark 

 

w

ill flash. 

The F2 appears in the screen 
when the faceplate is adjusted. 

Press the button 

“+” 

and 

“-“ 

to control the lift and drop of the faceplate. 

Pressing 

“+” 

button can stop the faceplate, while it is dropping. 

Pressing 

“-“ 

button can stop the faceplate, while it is lifting. 

Содержание KC-03.1 SPS

Страница 1: ...USER AND INSTALLATION MANUAL KC 03 1 SPS Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference ...

Страница 2: ...ecautions that should be brought to your attention during operation In order to ensure correct service of the wired controller please read this manual carefully before using the unit For convenience of future reference keep this manual after reading it ...

Страница 3: ...FUNCTION OF THE WIRED CONTROLLER 10 6 NAME ON THE LCD OF THE WIRE CONTROLLER 11 7 NAME OF BUTTON ON THE WIRE CONTROLLER 12 8 PREPARATORY OPERATION 13 9 OPERATION 14 10 TIMER FUNCTIONS 18 11 WEEKLY TIMER 19 12 SETTING STATIC PRESSURE FOR A6 DUCTS 23 13 FAULT ALARM HANDING 24 14 TECHNICAL INDICATION AND REQUIREMENT 24 ...

Страница 4: ...and fire Do not uninstall the controller randomly Random uninstalling may lead to abnormal operation heating of the equipment or fire on the air conditioner NOTE Do not install wired controller in a place vulnerable to leakage of flammable gases The contact with these gases may produce a fire Do not operate wired controller with wet hands and not let the water enter inside of controller Otherwise ...

Страница 5: ...te No Name Qty Remarks 1 Switch box 1 2 Wiring tube Insulating Sleeve Tightening Screw 1 Precautions to install wire controller 1 This manual provides the installation method of the wire controller Please refer to the wiring diagram of this installation manual to install the wire controller in the indoor unit 2 This wire controller working in low voltage circuit Is forbidden directly contact with ...

Страница 6: ...f wire controller Insert a screwdriver into slots in the lower part of the wire controller 2 places and remove the upper part of the wire controller Fig 3 2 NOTICE The PCB is mounted in the upper part of the wire controller Be careful not to damage the board with the slot screwdriver ...

Страница 7: ...o the pcb board of wired controller and make sure of polarity of the battery The positive of battery with positive of the installation place See Fig 3 5 Please set correct time the first time that you operate with controller The battery in the wire controller maintains the memory under power failure this mean that wired control not loses the time on the clock neither weekly timer When the power re...

Страница 8: ...om the top center 1 terminal of the indoor unit 2 notches to pass the wiring Connect terminals HA HB on the remote controller with terminals HA HB of the indoor unit HA and HB do not have polarity NOTE DO NOT allow water to enter the remote control Use the trap and putty to seal the wires ...

Страница 9: ...wiring during the assembly See Fig 3 6 4 SPECIFICATION Input Voltage DC 5V DC 12V Ambient temperature 5 43ºC 23 110ºF Ambient Humidity RH 40 RH90 Wiring specifications Wiring type Size Total Length Shielded 0 75 1 25 mm 50 m 164 All the pictures in this manual are only for explanatory purpose Your wired controller may be slightly different ...

Страница 10: ...wire layout design no raised part at backside more convenient to place the wires and install the device Room temperature display Weekly Timer Function Mode choose AUTO COOL DRY HEAT FAN Fan speed AUTO LOW MED HIGH Swing On some models Timer ON OFF Temperature Setting Weekly Timer Ifeel Child Lock LCD display Clock Faceplate Function On some models ...

Страница 11: ... Speed indication 9 Cº Fº Indication 3 Left right swing indication 10 Temperature Display 4 Up down swing indication 11 Lock indication 5 Faceplate function indication 12 Room temperature indication 6 Main unit and secondary unit indication 13 Clock display 7 Ifell function indication 14 On Off Timer 15 Timer display ...

Страница 12: ... THE BUTTONS ON THE WIRE CONTROLLER 1 MODE button 6 TIMER button 2 POWER button 7 DAY OFF DELAY button 3 ADJUST and button 8 COPY IFEEL button 4 FAN SPEED button 9 BACK TURBO button 5 SWING button 10 CONFIRM button ...

Страница 13: ...t pressing any button in 10 seconds you confirm date setting Next step is to adjust time of the clock Press the button or to set the current time Press repeatedly to adjust current time on 1 minute increases o 1 minute decreases Press and hold to increase o decrease the current time of the clock continuously Ex Monday AM 11 20 The setting is done after pressing Timer button or not pressing any but...

Страница 14: ...erature Indoor Setting Temperature Range 17 30ºC 62 86ºF 62 88ºF Depending on models Fan speed setting Press Fan speed button to set fan speed of the unit This button is unavailable in mode Auto or Dry Wired control temperature sensor selection Press Follow me button to select whether the ambient temperature is detected at the indoor unit or in wired controller When the Follow me function indicati...

Страница 15: ...buttons Back and Copy simultaneously for 3 seconds will alternate the temperature display between ºC and ºF Turbo Function on some models Press Turbo button to activate the turbo function Press button again to deactivate the turbo function When the turbo function is activated the mark appears Faceplate function on some models When the unit is off press Mode button long to activate the faceplate fu...

Страница 16: ...y press the louver swings 6 degrees 2 Press and hold the button for 2 seconds it turns into up down swing mode press it again to stop When the Up Down swing function is activated the mark appears Not applicable to all the models The operation can refer to the following instructions for the unit with four Up Down louvers can be operated individually 1 Press the Swing button to activate the Up Down ...

Страница 17: ...ing keys 15 seconds or press Back or press ON OFF drop out of query temperature When the air conditioning unit is off into the query function of temperature press or to select SP press Confirm to adjust the static pressure value When the air conditioning unit is off into the query function of temperature press or to select AF press Confirm into test mode press Back or press ON OFF or press Confirm...

Страница 18: ...ner will stop when the configured time has passed ON and OFF Timer Use this timer function to start and stop air conditioner operation The timer operates and air conditioner operation starts and stops after the time has passed To set the ON or OFF TIMER Press Timer button repeatedly to select the or Press Confirm button and Clock display will flash Ex Off timer set at PM 6 00 Press the button or t...

Страница 19: ...rs on the LCD and then press Confirm button to confirm 2 Day of the week setting Press the button or to select the day of the week and then press Confirm button to confirm the setting 3 ON TIMER setting of timer setting 1 Press the button or to set the time of ON TIMER and then press Confirm button to confirm the setting Ex Tuesday time scale 1 Up to 4 timer settings can be saved for each day of t...

Страница 20: ...econds the current setting will be restored and automatically we will leave of the weekly timer WEEKLY timer operation To activate WEEKLY TIMER operation Press Timer button and the mark appears on the LCD To deactivate WEEKLY TIMER operation Press Timer button and the mark disappear from the LCD To turn off the air conditioner during the weekly timer 1 If press Power button once the air conditione...

Страница 21: ...set day has passed DELAY function During the weekly timer if you pressing the Delay button once LCD screen display Press this button twice LCD screen show and wait 3 seconds to confirm This means the unit will override 1 hour Press this button three times LCD screen show and wait 3 seconds to confirm This means the unit will override 2 hours ex If press the DELAY button to select at 18 05 ˈ The ai...

Страница 22: ...ram During the weekly timer press Confirm button Press Copy button The letters CY will appear on the LCD Press Copy button to confirm The mark flashes quickly ex Copy the setting of the Monday to Wednesday Press Back button to back to the weekly timer Press the button or to select the day to copy from Press the button or to select the day to copy to The other days can be copied by repeating step 4...

Страница 23: ...emperature query status showing T1 2 Press and button to select SP to enter into parameter selecting interface Then press confirm button to adjust the parameter You can choose 0 4 0 constant airflow function Unit adjust the airflow volume automatically to be the same as standard airflow volume by adjusting the fan speed 1 non constant airflow airflow decreases as on way resistance increases 2 non ...

Страница 24: ...1 Communication error between wire controller and indoor unit F0 2 The face plate is abnormal F1 If the system continues still doesn t work well please check the display in the indoor unit to see if an alarm code appears in it If appear an alarm code please check it in the technical manual of the indoor unit 14 TECHNICAL INDICATION AND REQUIREMENT EMC and EMI comply with the CE certification requi...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: