Prevent water from 

flowing backwards 

1

Accessory Name

Qty. Sharp

Purpose

Owner’s & Installation

Manual

Installation and use instruction

This manual

1

One Way Valve

Discharge condensated water

Discharge condensated water

Fixed unit to prevent it toppling.

1

1

Pipe

short

for 

water condensation
Drain pipe for 

water condensation

1

1

2

Filter    
Ring    
Fixed strip

CAUTION

The site contains mineral oils such as 

lubricant of cutting machines.

Seaside where the air contains much salt.

Hot spring area where corrosive gases 

exist, e.g., sulfide gas.

Factories where the power voltage 

fluctuates seriously.

Inside a car or cabin.

The place with direct sunlight and other 

heat supplies. If  there’s no way to avoid 

these, please install a covering.

Place like kitchen where oil permeates.

Place where strong electromagnetic 

waves exist.

Place where flammable gases or materials 

exist.

Place where acid or alkali gases evaporate.

Other special environments.

WARNING

The unit must be securely fixed, elsewise, 

noise and shaking may be resulted.

Make sure that there’s no obstacle around 

the unit. 

In the place where there is strong wind like 

seashore, fix the unit in the location 

protected from the wind.       

Installing the unit in any of the following 

places may lead to malfunction(If it is 

inevitable, consult the supplier). 

2.1.2  How to transport

1)

2)

2.2  Location requirements

Enough space for installation and maintenance shall be 

preserved.    

The air inlet and outlet should be free from obstacles and strong 

wind.

The base surface should be flat, surface should be inclined no 

more than 2°and able to bear the weight of the unit and suitable 

for installing the unit without increasing noise or vibration.

The operation noise and air flow expelled shall not affect 

neighbors.    

No flammable gas is leaked nearby.

It is convenient for piping and wiring.

If it is installed in indoor space, it might cause indoor temp 

decreased and noise. Please take preventive measures for this.

If the unit has to be installed on a metal part of building, make 

sure the well electric insulation which should meet the relevant 

local electric standard. 

1)

2)

3)

4)

5)

6)
7)
8)

2.1  Unpacking

2.1.1  Accessories

2. BEFORE INSTALLATION

In order to avoid scratch or deformation 

of the unit surface, apply guard boards 

to the contacting surface.

No contact of fingers and other things 

with the vanes.

Don’t incline the unit more than 75° 

in moving, and keep it vertical when

installing.
This unit is heavy, it need to be carried by two or more persons, 

othewise might cause injury and damage.

>75°

Gradient limit>75°

The ambient air temperature must also be 

considered when installing this unit, in heat 

pump mode the ambient air temperature 

must be above -7

 and below 43

.If the 

ambient air temperature falls outside these 

upper and lower limits,the electrical 

elements will activated to meet the hot 

water demand and the heat pump does not 

operate.

The unit should be located in an area not 

subject to freezing temperatures. The unit 

located in unconditioned spaces(i.e., garages, 

basements, etc.) may require the water 

piping, condensate piping, and drain piping 

to be insulated to shelter agianst freezing. 

CAUTION

Table

.

2-1

3

Содержание COMPAK KHP-15/190 ACS2

Страница 1: ...y much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference COMPAK KHP 15 190 ACS2 Type Air source Heat Pump Water Heater OWNER S INSTAL...

Страница 2: ...ole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according...

Страница 3: ...re of this manual When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name Front Cover Electronic Control Box Compressor Display Cover Ele...

Страница 4: ...ker must be installed adjacent to the power supply Do not remove cover or deface any permanent instructions lables or the data label from either the outside of the unit or inside of unit panels Ask qu...

Страница 5: ...ngers such as water electricity and gas Before wiring pipes Before installation check whether the user s power supply meets the electrical installation requirements of unit including reliable groundin...

Страница 6: ...strong wind The base surface should be flat surface should be inclined no more than 2 and able to bear the weight of the unit and suitable for installing the unit without increasing noise or vibratio...

Страница 7: ...ir flow As an example a room that has an 2 5 tall ceiling and is 3 meter long by 2 meter wide would contain 15m 2 5 Unit outline dimension unit mm 4 2 3 Maintenance space requirements unit mm Fig 2 1...

Страница 8: ...o not dismantle the PT Valve Do not block off the drainage pipe It will cause explosion and injury if do not comply with the above instruction EXPLOSION Water inlet or outlet pipes The spec of the wat...

Страница 9: ...connects to duct air outlet without duct 2 2 5 5 2 2 5 5 Straight line length m Bent pressure drop Pa Bent s qty Straight line pressure drop Pa m Duct Description Duct Round duct Rectangle duct 160 1...

Страница 10: ...e pay attention to the drainage work we sugest to wrap the thermal insulated layer around ouside of the duct For the case of unit with duct the duct total length should be no more than 5m or the maxim...

Страница 11: ...itch are optional 1 After inserting the weak current connection cable group secure the weak current connection cable group using the two cable ties on the right of the junction box see Fig 3 13 2 The...

Страница 12: ...free of leaks Unit completely filled with water Water temperature limit valve or mixer tap recommanded installed per manufacturer s instructions Condensate Drain Line Installation Must be located wit...

Страница 13: ...stop heat pump activate E heater to continually heat water to the target temperature If manually activate the E heater running when heat pump running E heater and heat pump will work together until th...

Страница 14: ...ure is higher than 85 the TCO will automatically shut off the power of compressor and E heater After that it needs to be reset manually 1 2 3 4 4 2 4 Query function For the convenience of maintenance...

Страница 15: ...htened otherwise will be extinguished E heat will be lightened when E heat is running otherwise will be extinguished Solar will be lightened when the machine is connected to the solar signal or connec...

Страница 16: ...Adjust vacation days 1 360 days Switch to HYBRID mode Use this key to switch mode MODE CLOCK TIMER ON OFF DISINFECT No Icon Description 5 CLOCK CLOCK Press this button to enter the clock setting SET...

Страница 17: ...corresponding value will decrease by pushing When setting temperature press more than 1s temperature value will be decreased continuously When Setting clock timer press more than 1s Clock timer value...

Страница 18: ...con to add home appliance to your Comfort Home account Connected to the network Follow the insturctions in the app to set up the WiFi connection If the network connection fails please refer to the App...

Страница 19: ...s not have electric heating function the heat pump available running ambient range is 7 43 if ambient tempera ture is out of range system will show above mentioned signal to let user notice it Q Why s...

Страница 20: ...ture protection Tp 115 Protection active Tp 90 Protection inactive Maybe because of system blocked air or water or less refrigerant leakage in system after repair water temperature sensor malfunction...

Страница 21: ...time please Shut off the power supply Release all the water in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 M...

Страница 22: ...d around outside of Aluminum microchannel heat exchanger Hydrophilic aluminum fin inner groove copper tube 28W 560 1787mm 3150W Max operating pressure 1 0MPa Water tank cap Water heating cap 1500W 390...

Страница 23: ...is installed at least every 24 months 2 For equipment that contains fluorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more but of less than 500 tonnes of CO2 equipment at le...

Страница 24: ......

Отзывы: