background image

Installation & Owner's Manual

6

2

M

K

1

M

K

y

l

p

p

u

s

r

e

w

o

P

n

e

er

g/

w

oll

e

Y

yt

ic

a

p

a

c

n

a

F

m

et

I

tn

et

n

o

C

e

s

a

bl

a

ni

m

re

T

re

m

ro

fs

n

ar

T

kn

at

eh

tf

o

ed

is

ni

se

ri

w

de

tc

en

no

C

ro

tc

u

d

ni

la

ut

u

m

C

A

rot

cu

dni

lau

tu

m

yti

cir

tce

le

es

ah

p-

or

eZ

g

ul

p

tt

u

B

g

ul

p

tt

u

B

s

er

iw

g

ni

tc

e

n

n

o

c

y

al

e

R

y

al

e

R

hc

ti

w

s

ev

itc

et

or

p

er

ut

ar

ep

m

eT

kn

at

eh

tf

or

et

ae

h

cir

tc

el

er

ep

p

U

e

s

a

bl

a

ni

m

re

t

di

M

hct

iw

sy

re

vo

ce

re

rut

ar

ep

me

tci

ta

mo

tu

A

yt

ic

a

p

a

c

n

a

F

l

e

n

a

p

l

o

rt

n

o

c

n

i

a

M

y

a

r

G

e

ti

h

W

n

e

er

g/

w

oll

e

Y

h

g

u

o

r

h

t

t

e

g

h

c

i

h

w

,

s

e

ri

w

N

,

L

e

h

T

l

a

u

t

u

m

y

ti

c

ir

t

c

e

l

e

e

s

a

h

p

-

o

r

e

z

e

h

t

e

m

a

s

e

h

t

g

n

i

p

e

e

k

t

s

u

m

,r

o

t

c

u

d

n

i

,

e

s

i

w

r

e

h

t

o

,

g

n

ir

w

g

n

ir

u

d

n

o

it

c

e

ri

d

.

d

e

s

u

a

c

y

a

m

n

o

it

c

n

u

fl

a

m

m

e

t

s

y

s

.t

n

e

n

o

p

m

o

c

g

n

i

d

n

o

p

s

e

rr

o

c

e

h

t

h

ti

w

t

c

e

n

n

o

c

t

s

u

m

,

k

n

a

t

m

o

rf

t

u

o

s

e

m

o

c

e

ri

w

F

1

C

1

-

A

1

n)

w

o

r

(B

n)

w

o

r

(B

n

w

o

r

B

n

w

o

r

B

Blue

Blue

e

ti

h

W

d

e

R

e

u

l

B

n

e

er

g/

w

oll

e

Y

e

u

l

B

r

o

s

s

e

r

p

m

o

C

r

o

s

s

e

r

p

m

o

C

y

ti

c

a

p

a

C

e

di

s

ni

k

n

at

fo

m

ar

g

ai

d

g

ni

ri

W

k

c

a

l

B

d

e

R

e

u

l

B

e

u

l

B

Red

Black

E

U

P

M

O

C

n

w

o

r

B

Black

Red

k

c

a

l

B

d

e

R

Black

D

C

L

5

N

C

e

ti

h

W

4

2

N

C

8

1

N

C

k

c

a

l

B

U

5

T

4

T

3

T

L

5

T

P

T

H

-

O

R

P

w

oll

e

Y

0

2

N

C

9

1

N

C

6

1

N

C

6

N

C

8

2

N

C

1

N

C

0

4

N

C

7

2

N

C

)s

gn

itt

es

yr

ot

ca

fe

ht

re

tla

ot

w

oll

ar

ev

en

re

s

U(

no

itc

el

es

le

do

M

tc

ef

ni

si

D

ht

i

W

le

d

o

m

L

0

9

1

r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

n

o

it

c

u

S

r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

t

n

e

i

b

m

A

4

T

r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

r

o

t

a

r

o

p

a

v

E

3

T

)r

e

p

p

U

(r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

k

n

a

T

U

5

T

)r

e

w

o

L

(r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

k

n

a

T

L

5

T

r

o

s

n

e

s

e

r

u

t

a

r

e

p

m

e

t

e

g

r

a

h

c

s

i

D

P

T

H

T

tc

ef

ni

si

D

tu

o

ht

i

W

r

e

t

a

e

H

ci

rt

c

e

l

E

h

ti

W

r

e

t

a

e

H

ci

rt

c

e

l

E

t

u

o

h

ti

W

le

d

o

m

L

0

0

3

H

T

h

c

ti

w

S

n

o

it

c

e

t

o

r

P

e

r

u

s

s

e

r

P

h

g

i

H

H

-

O

R

P

n

w

o

r

B

e

u

l

B

e

u

l

B

e

u

l

B

d

e

R

k

c

a

l

B

d

e

R

d

e

R

Black

e

u

l

B

)s

gn

itt

es

yr

ot

ca

fe

ht

re

tla

ot

w

oll

ar

ev

en

re

s

U(

no

itc

el

es

le

do

M

z

H

0

6-

y

c

n

e

u

q

er

fr

e

w

o

P

,sl

io

c

yg

re

ne

ral

os

eh

tll

at

sn

io

ts

de

en

m

ot

su

c

eh

tfI

hti

w

de

tc

en

no

c

eb

ot

sd

ee

nl

an

im

re

t6

2

N

C

eh

tn

eh

t

eh

ts

eil

pp

us

2

N

C

eh

T.

yl

pp

us

re

w

op

V

04

2

~

02

2

eh

t

,p

m

up

re

ta

w

yg

re

ne

ral

os

eh

tr

of

la

ng

is

lor

tn

oc

,ro

tc

at

no

c

C

A

eh

ty

b

de

llo

rt

no

c

eb

ts

u

m

p

m

up

re

ta

w

eh

td

na

.yl

tc

eri

d

p

m

up

re

ta

w

eh

te

vir

dt

on

dl

uo

hs

la

ni

m

re

t2

N

C

eh

ts

a

.d

oh

te

m

gn

iri

w

ro

fs

na

ici

nh

ce

tr

ot

ub

irt

si

d

tc

at

no

c

es

ae

lP

6

2

N

C

2

N

C

z

H

0

5-

y

c

n

e

u

q

er

fr

e

w

o

P

ro

tc

at

n

o

C

C

A

9

SW1

SW2

Red

Owner should install the 

filter by self, and the mesh 

size is about 1.2mm.

Unit

Unit

Rain

Rain

Weather shed

 Filter

inlet

oulet

≥ 

2.5D

ΦD

 Filter

Drain

≤2

o

Drain

NOTE

●  The resistance of duct will decrease air-flow-rate, which will 

lead to capacity of unit decreased.

●  For the case of unit with duct, the duct total length should be 

no more than 10m or the maximus static pressure should be 

within 25Pa, and the quantity of bending should be no more 

than 3.

●  For unit with duct, when unit operating, condensate will be 

generated aroud outside of duct. Please pay attention to the 

drainage work, we sugest to wrap the thermal insulated layer 

around ouside of the duct.

●  It is recommended to install the unit in the indoor space, it is 

not allow to install the unit at the rainy space.

Fig.3-6

Fig.3-7

WARNING

●  In case of rain entering to internal components of the unit, the 

component might be damaged or causing physical danger. 

(

Fig.3-6

)

●  In terms of the unit connects with duct reaching to outdoor, a 

reliable water-resistant measure must be conduct on the duct, 

to prevent water from dropping into internal of the unit. (

Fig.3-7

)

5)  Filter installing at the unit inlet. In terms of the unit with duct, filter 

in there must be put on the position of duct inlet. (

Fig.3-8/3-9

)

Fig.3-8

Fig.3-9

6)  To smoothly drain condensate from unit, please install the unit at 

a horizontal floor. Otherwise, please ensure the drain vent is at 

the lowest level. Recommending the inclination angle of unit to the 

ground should be no more than 2°.

Fig.3-10

Содержание COMPAK KHP 15/190 ACS1

Страница 1: ...ry much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Type Air source Heat Pump Water Heater COMPAK KHP 35 300 ACS1 OWNER S INSTALLATION MANUAL ...

Страница 2: ...upply is earthed well please don t install the unit Please have a qualified person perform the reliable earthing connection and the installation of the unit Examples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel Your safety is the most important thing we concerned ...

Страница 3: ...ver Top Cover Air Inlet Fan Assy Evaporator Filter Air Outlet Water Inlet Anode Rod Drain Pipe Anode Rod PARTS NAMES When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name All the pictures in this manual are for explanation purpose only They may be slightly different from the heat pump water heater you purchased depand on model Please...

Страница 4: ... 1 2 5 9 4 42 Fig 0 1 NOTE Above calculation is based on the ideal condition the final cost bill will be different caused by the actual running conditions such as running period ambient temperature etc 1 SAFETY INFORMATION Please read thoroughly all of the instrucitons before installing or operating the unit Following safety symbols are very important always read and obey all safety symbols CAUTIO...

Страница 5: ...y sink and result in injury Arrange the drain pipe to ensure smooth draining Improper drainage work may cause wetting of the building furniture etc Do not touch the inner parts of the controller Do not remove the front panel Some parts inside are dangerous to touch otherwise a machine malfunction may be caused Do not turn off the power supply System will stop or restart heating automatically A con...

Страница 6: ...tting machines Seaside where the air contains much salt Hot spring area where corrosive gases exist e g sulfide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The place with direct sunlight and other heat supplies If there s no way to avoid these please install a covering Place like kitchen where oil permeates Place where strong electromagnetic waves exist Place w...

Страница 7: ...e of PTR valve should be pulled out once per half a year to make sure that there is no jam of the valve Please beware of burn beware of the hot water from the valve The drainage pipe should be well insulated in order to prevent water inside pipe from freezing in cold weather WARNING Do not dismantle the PTR valve Do not block off the drainage pipe It will cause explosion and injury if do not compl...

Страница 8: ... to install unit by this way in summer that could charge fresh air into room 3 Air outlet connects to duct air inlet without duct B C 10m Fig 3 5 It is recommended to install unit by this way in the winter where there is other heat source in the room 4 Duct Description Table 3 1 Duct Round duct Rectangle duct Other shaped duct Dimension mm Φ190 190X190 Refer to above data Straight line pressure dr...

Страница 9: ...side of the duct It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 6 Fig 3 7 WARNING In case of rain entering to internal components of the unit the component might be damaged or causing physical danger Fig 3 6 In terms of the unit connects with duct reaching to outdoor a reliable water resistant measure must be conduct on the du...

Страница 10: ...e u l B e u l B e u l B d e R k c a l B d e R d e R Black e u l B s g n i t t e s y r o t c a f e h t r e t l a o t w o l l a r e v e n r e s U n o i t c e l e s l e d o M z H 0 6 y c n e u q e r f r e w o P s l i o c y g r e n e r a l o s e h t l l a t s n i o t s d e e n m o t s u c e h t f I h t i w d e t c e n n o c e b o t s d e e n l a n i m r e t 6 2 N C e h t n e h t e h t s e i l p p u s ...

Страница 11: ...sinfect Table 3 5 SW2 Model selection User never allow to alter the factory settings ON OFF S W 1_1 300L model 190L model SW 1_2 Power furquency_60Hz Power furquency_50Hz 3 3 5 Electric leakage protector Fig 3 13 3 4 Installation checklist 3 4 1 Location The flooring beneath the water heater must be able to support the weight of the unit when filled with water more than 445kg Located indoors such ...

Страница 12: ... Condensate Drain Line Installation Must be located with access to an adequate drain or condensate pump Condensate drain lines installed and piped to an adequate drain or condensate pump 3 4 4 Electrical Connections The water heater requires 230 VAC for proper operation Wiring size and connections comply with all local applicable codes and the requirements of this manual Water heater and electrica...

Страница 13: ...e default heating source is heat pump If ambient is range out of heat pump heat pump will stop running the unit will shift automatically to activate E heater and show the icon LA on the display then if the ambient temperature goes into the running range of heat pump again it will stop E heater and shift automatically to heat pump again and the icon LA will be extinguished If the target setting wat...

Страница 14: ...NOTE While the ambient temperature below than 7 C heat pump efficiency will decrease dramatically the unit will automatically shift to E heater running 4 2 3 Basic function 1 Weekly disinfect function Under disinfection unit immediately start to heat water up to 65 C to kill the potential legionella bacteria inside water of tank icon will light on the display screen during disinfection Unit will q...

Страница 15: ... unit is under disinfecting otherwise will be extinguished will be lightened if disinfect function is automatically activated by unit will flash with 0 5 Hz frequency if disinfect function is manually activated will flash with 2Hz frequency when setting disinfect function or setting disinfect timer High temp Alarm If setting water temp is higher than 50 C will be lightened otherwise will be exting...

Страница 16: ...re value will be increased continuously When Setting clock timer press more than 1s Clock timer value will be increased continuously When setting vacation days press more than 1s day value will be increased continuously On querying check items will page up by pressing No Icon Description 3 1 3 1 Set Clock Press button for 3 sec to enter clock setting Then icon will be lightened and the hour value ...

Страница 17: ...ting clock timer press more than 1s Clock timer value will be decreased continuously When setting vacation days press more than 1s day value will be decreased continuously On querying check items will page down by pressing No Icon Description CONFIRM UNLOCK If screen and buttons are unlocked press it to upload setting parameters after setting any parameter If press it within 10sec setting paramete...

Страница 18: ...om part of bank if the cold water surface emerge the upper temperature sensor temperature shown on the display will decreased dramatically Q Why sometimes the temperature shown on the display is decreased a lot but there is still a mount of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when display temperature starts falling down quickly it means there i...

Страница 19: ...CB has released or sensor has been broken Contact a qualified person to service the unit E5 Ambient temperature sensor T4 error Maybe the connection between sensor and PCB has released or sensor has been broken Contact a qualified person to service the unit E6 Compressor discharge temperature sensor TP error Maybe the connection between sensor and PCB has released or sensor has been broken Contact...

Страница 20: ... unit 7 MAINTENANCE 7 1 Maintenance 1 Check the connection between power supply plug and socket and ground wiring regularly 2 In some cold area below 0 C if the system will be stopped for a long time all the water should be released in case of freezing of inner tank and damage of E heater 3 It is recommended to clean the inner tank and E heater every half year to keep an efficient performance 4 Ch...

Страница 21: ...let water temp Default 55 C 38 65 C adjustable Water side exchanger Safety condenser copper tube wrapped around outside of storage tank Inlet pipe Dia DN20 Outlet pipe Dia DN20 Drain pipe Dia DN20 PTR valve Dia DN20 Max pressure 1 0MPa Exchanger air side Material Hydrophilic aluminum fin inner groove copper tube Motor power 80W Air circulation way outlet inlet vertically duct connection available ...

Страница 22: ...a leakage detection system is installed at least every 24 months 2 For equipment that contains fluorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more but of less than 500 tonnes of CO2 equipment at least every six months or where a leakage detection system is installed at least every 12 months 3 For equipment that contains fluorinated greenhouse gases in quantities of 50...

Страница 23: ......

Отзывы: