Installation & Owner's Manual
11
0
1
2
3
4
5
6
7
8
9
-25
-15
-5
5
15
25
35
45
Ti
m
e,
h
ou
r
Ambient temperature(
℃
)
Heat Up Time within Different Temperature
15-45
℃
15-55
℃
15-65
℃
0.00
1.00
2.00
3.00
4.00
5.00
6.00
-25
-15
-5
5
15
25
35
45
CO
P
Ambient temperature(
℃
)
COP within Different Temperature
15-45
℃
15-55
℃
15-65
℃
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
-25
-15
-5
5
15
25
35
45
Ca
pa
ci
ty
,
W
Ambient temperature(
℃
)
Capacity within Different Temperature
15-45
℃
15-55
℃
15-65
℃
● About TCO and ATCO
The power of E-heater will be automatically shut-off or turn on
by TCO and ATCO.
If the water temperature is higher than 78°C, the ATCO will
automatically shut off the power of compressor and E-heater,
and reconnect it if the temperature falls down below 68°C.
If the water temperature is higher than 85°C, the TCO will
automatically shut off the power of compressor and E-heater.
After that it needs to be reset manually by pressing the red
button on the TCO.
● Restart After a Long Term Stop
When the unit is restarted after a long term stop(trail running
included), it is normal that outlet water is unclean. Keep the tap
on and the water will be clean soon.
Fig.4-4
Fig.4-5
Fig.4-6
NOTE
While the ambient temperature below than -7°C, heat pump
efficiency will decrease dramatically, the unit will automatically
shift to E-heater running.
4.2.3 Basic function
1) Weekly disinfect function
Under disinfection unit immediately start to heat water up to 65°C
to kill the potential legionella bacteria inside water of tank,
icon will light on the display screen during disinfection. Unit will
quit disinfection if water temperature is higher than 65°C and
extinguish icon.
2) Vacation function
After pressing
button, unit will automatically heat water to
15°C for the purpose of energy saving during vacation days.
3) How is the unit running
If unit is OFF->press
ON/OF F
ON/OFF
->unit will be waken->press to
set target water temperature(38-65°C)->press
->unit will
automatically select heat source and start to heat water to target
temperature.
4.2.4 Query function
For the convenience of maintenance and debug, query function is
available by press 2 buttons together:
+
, then
system running parameters will be shown one by one with following
sequence by each pushing of
or
button.
Table.4-3
No.
Hour
low bit
Min.
high bit
Min. Low
bit
Temp./
Dasys
Explenation
1
Temp.
T5U
2
Temp.
T5L
3
Temp.
T3
4
Temp.
T4
5
Temp.
TP
6
Temp.
TH
7
Current
Compressor
8
Last error code
9
Previous 1st error or
protection code
10
Previous 2nd t error
or protection code
11
Software number
Emptying
Drainpipe shut-off valve
Close
After emptying, please replace the nut of
drainpipe.
Tank
Temperature sensor(T5U)
Electric heater
Water inlet
Water outlet
Temperature sensor(T5L)