P_s
N
22
23
SOLAR PUMP
Control signal output
SV2
N
18
19
SV1
ON
6
OFF
7
N
21
SV3
ON
12
OFF
24
N
23
Voltage
220-240VAC
Maximum running current(A)
0.2
Wiring size(mm
2
)
0.75
Control port signal type
Type 2
CLOSE: SHUT DOWN
M1
M2
9
10
P_c
N
16 17
PUMPC
CONTROL SIGNAL
OUTPUT
P_d
N
PUMPC
CONTROL SIGNAL
OUTPUT
29 30
P_d
N
PUMPC
CONTROL SIGNAL
OUTPUT
37 38
44
45
NOTE
For 5/7/9 kW units, the terminal number is 37 and
38. For 12/14/16 kW units, the terminal number is
29 and 30.
NOTE
NOTE
2) For 2-way valve SV2:
a) Procedure
● Connect the cable to the appropriate terminals as shown
in the picture.
● Fix the cable reliably.
3) For 3-way value SV3
4) For 3-way value SV1
a) Procedure
● Connect the cable to the appropriate terminals as shown
in the picture.
● Fix the cable reliably.
5) For remote shut down:
6) For tank loop pump P_d and mix pump P_c:
a) Procedure
● Connect the cable to the appropriate terminals as
shown in the picture.
● Fix the cable reliably.
Voltage
220-240VAC
Maximum running current(A)
0.2
Wiring size(mm
2
)
0.75
Control port signal type
Type 2
Only a normal closing valve is available for
this unit
Voltage
220-240VAC
Minimum circuit amps (MCA)
0.2
Wiring size(mm
2
)
0.75
Control port signal type
Type 2
Wiring of the 3-way valve is different for NC
(normal close) and NO (normal open). Before
wiring, read the Installation & Owner's manual
for the 3-way valve carefully and install the
valve as showed in the picture. Make sure to
connect it to the correct terminal numbers.
Voltage
220-240VAC
Maximum running current(A)
0.2
Wiring size(mm
2
)
0.75
Control port signal type
Type 2