
The position of barycenter for different units can be seen in the picture below.
07
To avoid injury, do not touch the air inlet or aluminum fins of the unit.
Do not use the grips in the fan grills to avoid damage.
The unit is top heavy! Prevent the unit from falling due to improper inclination during handling.
CAUTION
5 IMPORTANT INFORMATION FOR THE REFRIGERANT
This product has the fluorinated gas, which is forbidden to release to air.
Refrigerant type: R32; Volume of GWP: 675.
GWP=Global Warming Potential
Factory charged refrigerant volume in the unit
Refrigerant/kg
Tonnes CO
2
equivalent
4kW
1.40
0.95
6kW
1.40
0.95
8kW
1.40
0.95
12kW
1.75
1.18
14kW
1.75
1.18
16kW
1.75
1.18
Model
4/6 kW (unit:mm)
A
A
C
B
C
A
B
A
8/10/12/14/16 kW (unit:mm)
10kW
1.40
0.95
Model
AA
1 phase 4/6kW
1 phase 8/10kW
B
C
1 phase 12/14/16kW
3 phase 12/14/16kW
295
540
190
330
580
280
290
605
245
200
605
245
The hook and barycenter of
the unit should be on a line
in vertical direction to
prevent improper inclination
Make the rope go through
the lifting holes from both
the right and left sides in the
wooden collet
≥
1000mm
Protect Angle
Содержание Aquantia KHP-MO 4 DVR2
Страница 2: ......
Страница 23: ...19 Tank booster heater n d e d n d Automatic air purge valve r d r manometer d r...
Страница 74: ...70 9 5 10 4...
Страница 84: ...20 21 Automatic air purge valve Pressure relief valve...
Страница 87: ...16125300002999 V C...
Страница 88: ......