background image

04

WARNING

 

● The refrigerant in the air conditioner is 

relatively safer, and usually does not leak. If 

the refrigerant leaks, and comes in contact 

with burning objects in the room, it will 

produce harmful gases.

 

● Shut down any flammable heating device, 

ventilate the room and contact the agent of 

the unit immediately.

 

● Do not use the air conditioner again until the 

maintenance personnel has confirmed that 

the refrigerant leakage has been sufficiently 

resolved.

WARNING

 

● Do not attempt to modify, dismantle, 

remove, reinstall or repair this unit, as 

the improper dismantling or installation 

may result in electric shock or fire. Please 

contact the agent. 

 

● If the refrigerant accidentally leaks, make 

sure that there is no fire around the unit. 

The refrigerant itself is completely safe, 

non-toxic and non-flammable, but it will 

produce toxic gases when it accidentally 

leaks and comes in contact with flammable 

substances gener-ated by existing heaters, 

and burning devices in the room. You must 

get a qualified mainte-nance personnel to 

verify that the point of leakage has been 

repaired or rectified before you restore the 

operations of the unit.

WARNING

 

● When any unusual situations arises (burning 

odour, etc.), stop the unit immediately and 

turn off the power.

 

● As a result of a certain situation, the unit 

has caused damage, an electric shock, or a 

fire. Please contact the agent.

 

● Clean the air filter and external shell of the unit. 

Please contact the installation or maintenance 

personnel to clean the air filter and external shell of 

the indoor unit. The installation/operation manual 

of the specialized indoor unit includes maintenance 

tips and cleaning procedures. Make sure that the 

clean air filter is installed in its original position. 

6.3 About the Refrigerant 

This product contains fluorinated greenhouse gases as 

stipulated in the Kyoto Protocol. Do not discharge the 

gas into the atmosphere. 
Refrigerant Type: R-410A 
GWP Value: 2088 
Based on the applicable law, the refrigerant must be 

checked regularly for leakages. Please contact the 

installation personnel for more information.

6.4  After-sales Service and 

Warranty 

6.4.1 Warranty period 

This product contains the warranty card that was 

completed by the agent during installation. The 

customer must check the completed warranty card and 

keep it properly. 
If you need to repair the air conditioner during the 

warranty period, please contact the agent and provide 

the warranty card. 

6.4.2  Recommended maintenance 

and inspection 

As the use of the unit for many years will eventually 

lead to a dust layer, the performance of the unit will 

degenerate to a certain extent. As professional skills 

are needed to dismantle and clean the unit, and for the 

optimal maintenance effects of this unit, please contact 

your agent for more details. 
When you request the agent for assistance, please 

remember to state: 

 

● Complete model name of the air conditioner.

 

● Date of installation.

 

● Details on the fault symptoms or errors, and any 

defects.

6.4.3  Shorter maintenance and 

replacement cycle 

In the following situations, the "maintenance cycle" and 

"replacement cycle" may be shortened.
The unit is used in the following situations: 

 

● Temperature and humidity fluctuations are outside 

the normal ranges. 

 

● Large power fluctuations (voltage, frequency, 

waveform distortion etc.) (must not use the unit if the 

power fluctuations exceed the allowed range). 

 

● Frequent collisions and vibrations. 

 

● The air may contain dust, salt, harmful gas or oil 

such as sulphite and hydrogen sulphide. 

 

● Frequent on and off of unit or operating time is too 

long (in places where the air conditioning is on for 24 

hours a day).

7 TROUBLESHOOTING

The warranty does not cover the damage caused by 

dismantling or cleaning of the internal components by 

unauthorized agents.

Содержание Amazon IV HR K3F-252 DN4S

Страница 1: ...itioner please read this manual carefully and keep it for future reference The figure shown in this manual is for reference only and may be slightly different from the actual product Amazon IV HR Seri...

Страница 2: ...ry Program 03 6 MAINTENANCE AND REPAIR 6 1 Maintenance after Unit has been Shut Down for a Long Period 03 6 2 Maintenance Before Unit is Shut Down for a Long Period 03 6 3 About the Refrigerant 04 6 4...

Страница 3: ...rate the air conditioner when applying fumigated insecti cide in the room This may cause chemicals to be deposited inside the unit and pose a danger to the health of people allergic to chemicals This...

Страница 4: ...C DB Cooling 15 24 C WB Heaing 15 30 C DB Indoor humidity 80 2 Notes 1 15 C cooling is possible only with the single MS box otherwise the minimum allowable cooling operating temperature is 5 C 2 Conde...

Страница 5: ...e running light is now off and the system stopped running Adjust Refer to the user manual for the controller on how to set the required temperature fan speed and air flow direction 5 3 Using the Dry P...

Страница 6: ...ins fluorinated greenhouse gases as stipulated in the Kyoto Protocol Do not discharge the gas into the atmosphere Refrigerant Type R 410A GWP Value 2088 Based on the applicable law the refrigerant mus...

Страница 7: ...inlets or outlets of the outdoor or indoor units are blocked by any obstacles Remove the obstacles and maintain good ventilation in the room Check if the filter is blocked please refer to the Maintena...

Страница 8: ...peration is set However a test operation is not performed for 30 minutes after power on Displayed on the unit with the error xP9 DC fan module protection Displayed on the unit with the error PL Compre...

Страница 9: ...g operation will become steam to be discharged out of the system 7 2 6 Fault symptom Noise from air conditioner indoor unit A zeen sound is heard the moment the system is powered on This noise is prod...

Страница 10: ...logy to move the units 9 DISPOSAL This unit uses hydrogen fluorocarbons Please contact the agent when you want to dispose this unit Based on the requirements of the law the collection transportation a...

Страница 11: ...16127000003327 V C...

Страница 12: ......