The self-filling Kaycee syringes can be fitted with:

a. rear connector and tube feed into vaccine container
b. Multifit bottle holder
c. Cap assembly and bottle.

a

  Fit the PVC feed tube to rear connector and 

short vaccine feed needle to the other end of the 
tube. Attach feed needle to vaccine container. 
If container is rigid, use of an air needle will be 
required to relieve vacuum;

 

s

  

FAILuRe TO ReLIeve vAcuum mAy ResuLT 
IN uNDeR-DOsING 

b

 

(Please note the multifit can be located on top or 
rear of vaccinator as required.)

-To attach bottle to Multifit holder first remove red 

needle cover from air vent needle.

-Carefully remove the seal from the cap of the 

bottle, ensuring the remaining cap is left in place.

-Pierce centre of rubber seal firmly so bottle head 

enters ‘crown’ of Multifit holder.

-Slide and click ring completely over crown 

segments to lock bottle.

-If ring doesn’t click over round crown segments, 

loosen crown anti-clockwise and try again.

-Once it has clicked, turn crown clockwise for final 

adjust.

c

  When using cap assembly and bottle, fill bottle with 

vaccine and screw inverted syringe firmly down 
onto bottle.

d

  Once vaccine is connected using desired 

attachment, fit hypodermic needle to front stem 
(ensuring needle is facing away from operator) and 
pump the trigger several times to prime the device 
until fluid flows from the needle. Your syringe is 
now ready for use.

3. Connect vaccine

Содержание AVIJECTOR

Страница 1: ...INSTRUCTION AND MAINTENANCE MANUAL AVIJECTOR HAND HELD SELF FILLING REPEATER SYRINGE adjustable dosage MK25 0 25ml 0 5ml 1 0ml...

Страница 2: ...co uk Your Kaycee syringe is a hand operated repeater syringe which has been designed for use with all oil and water based vaccines It is comfortable to handle and its ergonomic design allows long ses...

Страница 3: ...needle or Multifit Direct Bottlemount or Cap assembly and bottle unscrew bottle from cap c Boil for 10 minutes d Allow to cool refit handle and pump out water 1 Sterilisation 2 Setting the dose In ord...

Страница 4: ...t needle Carefully remove the seal from the cap of the bottle ensuring the remaining cap is left in place Pierce centre of rubber seal firmly so bottle head enters crown of Multifit holder Slide and c...

Страница 5: ...with a short piece of PVC tubing attached to the front stem to draw the vaccine through b The syringe is designed and built to give a high degree of accuracy If accuracy should fail check for residua...

Страница 6: ...semi sphere 10182 06 Trigger screw 10194 07 Trigger 10200 08 Handle grip 10212 09 Adjusting screw 10249 10 Hexagon screw tapped 10261 11 Hexagon screw plain 10273 12 Main body 10327 13 Side arm left...

Страница 7: ......

Страница 8: ...ve conical 10170 05 Suction valve semi sphere 10182 06 Trigger screw 10194 07 Trigger 10200 08 Handle grip 10212 09 Adjusting screw 10249 10 Hexagon screw tapped 10261 11 Hexagon screw plain 10273 12...

Страница 9: ......

Страница 10: ...Trigger screw 10194 07 Trigger 10200 08 Handle grip 10212 09 Adjusting screw 10249 10 Hexagon screw tapped 10261 11 Hexagon screw plain 10273 12 Main body 10327 13 Side arm left 10388 Side arm right...

Страница 11: ......

Страница 12: ...www kaycee co uk Visit our website to see our full range of syringes and accessories Distributor...

Отзывы: