The self-filling Kaycee syringes can be fitted with:
a. rear connector and tube feed into vaccine container
b. Multifit bottle holder
c. Cap assembly and bottle.
a
Fit the PVC feed tube to rear connector and
short vaccine feed needle to the other end of the
tube. Attach feed needle to vaccine container.
If container is rigid, use of an air needle will be
required to relieve vacuum;
s
FAILuRe TO ReLIeve vAcuum mAy ResuLT
IN uNDeR-DOsING
b
(Please note the multifit can be located on top or
rear of vaccinator as required.)
-To attach bottle to Multifit holder first remove red
needle cover from air vent needle.
-Carefully remove the seal from the cap of the
bottle, ensuring the remaining cap is left in place.
-Pierce centre of rubber seal firmly so bottle head
enters ‘crown’ of Multifit holder.
-Slide and click ring completely over crown
segments to lock bottle.
-If ring doesn’t click over round crown segments,
loosen crown anti-clockwise and try again.
-Once it has clicked, turn crown clockwise for final
adjust.
c
When using cap assembly and bottle, fill bottle with
vaccine and screw inverted syringe firmly down
onto bottle.
d
Once vaccine is connected using desired
attachment, fit hypodermic needle to front stem
(ensuring needle is facing away from operator) and
pump the trigger several times to prime the device
until fluid flows from the needle. Your syringe is
now ready for use.
3. Connect vaccine