background image

 
 

Camera Link Range Extender over Fiber User Manual  

22 

 

 

6.4

 

IO Connector  

The  extender  incorporates  two  RJ45  connectors  to  provide  GPIO  functionality  such  as  TTL, 

Opto Coupled, RS232 and RS422.  The pin-out of the connectors can be found in the tables and 

diagram below.  

Pin number 

Name 

Description 

TTL0 

Bidirectional TTL signal 

OptoCoupled Output 

Opto Isolated output 

RS232 RX 0 

RS232 Receive 

OptoCoupled GND 

Opto Isolated Ground 

GND 

Signal ground 

RS232 TX 0 

RS232 Transmit 

TTL1 

Bidirectional TTL signal 

OptoCoupled Input 

Opto Isolated input 

Table 7 : Top I/O connector pinout 

 

Pin number 

Name 

Description 

RS422 RXp 

RS422 positive receive 

RS422 RXn 

RS422 negative receive 

GND 

Signal ground 

RS422 TXp 

RS422 positive transmit 

RS422 TXn 

RS422 negative transmit 

GND 

Signal ground 

RS232 TX 1 

RS232 transmit 

RS232 RX 1 

RS232 receive 

Table 8 : Bottom I/O connector pinout 

 

 

Firmware 

Содержание KY-CL2F-D

Страница 1: ...e Extender over Fiber User Manual 9 201 February 20 aMesila St Nesher 3688520 Israel P O B 2 5 0 0 4 H a i f a 3 1 2 5 0 0 1 I s r a e l Tel 972 72 2723500 Fax 972 72 2723511 w w w k a y a i n s t r u...

Страница 2: ...1 5 1 1 Camera Link Frame Grabber installation 11 5 1 2 Installing and Removing SFP Modules 12 5 1 3 Precautions 12 5 1 4 Installing the SFP Module 13 5 1 5 Connecting the interface cable to SFP Modul...

Страница 3: ...ications 27 8 1 Dimensions 27 8 2 Weight 28 9 Appendices 29 9 1 Camera Link cables 29 9 2 Fiber cables 29 10 Ordering information 30 Revision History Contents Version Date Notes 1 0 05 01 16 Initial R...

Страница 4: ...FIGURE 14 EXTERNAL DIMENSIONS OF THE KY EXT CL CAMERA LINK SIDE PANEL 27 FIGURE 15 EXTERNAL DIMENSIONS OF THE KY EXT CL FIBER SIDE PANEL 27 FIGURE 16 EXTERNAL DIMENSIONS OF THE KY EXT CL ENCLOSURE BOX...

Страница 5: ...amera Link Range Extender over Fiber User Manual 4 TABLE 15 KY EXT CL RS232 INPUT SPECIFICATIONS 26 TABLE 16 KY EXT CL RS232 OUTPUT SPECIFICATIONS 26 TABLE 17 ORDERING INFORMATION 30 Figures and Table...

Страница 6: ...lectric shock may occur due to a short circuit or heat generation For inspection modification or repair contact our sales personnel Do not touch a cooling fan As a cooling fan rotates in high speed do...

Страница 7: ...no responsibility for any damages caused by the following Earthquake thunder natural disaster or fire resulting from the use beyond our responsibility acts caused by a third party or other accidents t...

Страница 8: ...the camera side KY CL2F D Device Unit and one on the Camera Link Frame Grabber side KY CL2F H Host Unit The system uses flexible SFP modules for optical connection that can be easily changed The range...

Страница 9: ...ications High speed cameras High definition cameras Panoramic cameras Defense remote systems Surveillance Robotic Vision 3 3 Optional accessories 12V 3A 36W power supply Camera Link cables Fiber cable...

Страница 10: ...igure 1 KY EXT CL external view Each of the Camera Link and SFP connectors is paired with a status LED and there is a system status LED see 4 3 section describing the LED status The power connector us...

Страница 11: ...the LED will constantly light orange The Camera Link LED s behavior is described in Table 1 LED state Condition Slow pulse red No valid Camera Link link detected Solid red PoCL failure Overcurrent Und...

Страница 12: ...Grabber Power supply Camera Link Fiber cable up to 80 km Camera Link Range Extender Host unit Camera Link Range Extender Device unit Power supply Figure 3 KY EXT CL connection diagram 5 1 1 Camera Li...

Страница 13: ...tical ports of an SFP module 4 Removing and inserting a module can shorten its useful life so you should not remove and insert the module any more often than is absolutely necessary 5 Insert the clean...

Страница 14: ...etc 2 The SFP module has a bale clasp that used to remove or install the SFP module 3 Close the bale clasp before inserting the SFP module 4 Line up the module with the port and slide it into the port...

Страница 15: ...hrough 3 only one fiber cable should be connected This cable is connected between TX output Marked with TX or Arrow outwards the SFP on the Camera Link Extender Device unit and RX input Marked with RX...

Страница 16: ...the camera and the computer off 2 Disconnect and remove all interface cables from the ports 3 Open the bale clasp on the SFP module with your index finger or a small flat blade screwdriver in a downwa...

Страница 17: ...k Range Extender over Fiber User Manual 16 Figure 8 Opening the bale clasp of an SFP Module Figure 9 Removing an SFP Module from the port Figure 10 SFP Module with bale clasp open Installation and Con...

Страница 18: ...F D and KY CL2F H power supply connector The KY EXT CL Host and Device requires 12V power supply for proper function for camera Please refer section 7 2 of this document for exact Power Supply require...

Страница 19: ...FP is replaced by CWDM SFP that is able to transmit and receive the data on specific wavelength By using these SFP modules the system can be integrated into existing CWDM infrastructure by usage of ex...

Страница 20: ...bed in Table 3 Parameter Value Baud rate 115200 Start bits 1 Stop bits 1 Parity None Flow Control None Table 3 Serial emulated terminal configurations 6 2 Terminal commands The following commands are...

Страница 21: ...ive 6 2 3 KY CL2F H Host Unit configuration In order to format the system choose the required command sequence Command Description Available options format mode 1 Base mode 2 Medium mode 3 Full mode 4...

Страница 22: ...firmware update please start file transfer using XMODEM 6 At this point all the LEDs will turn off and the System status LED will slow pulse orange indicating the extender is ready to receive the firm...

Страница 23: ...o Isolated output 3 RS232 RX 0 RS232 Receive 4 OptoCoupled GND Opto Isolated Ground 5 GND Signal ground 6 RS232 TX 0 RS232 Transmit 7 TTL1 Bidirectional TTL signal 8 OptoCoupled Input Opto Isolated in...

Страница 24: ...Camera Link Range Extender over Fiber User Manual 23 Figure 13 Serial RJ45 connector diagram Firmware...

Страница 25: ...ximum ratings 7 2 Operating conditions Parameter Description Minimum Typical Maximum Vcc Supply voltage 11 V 12V 13 V Icc Host Supply Current from PoCL or external power supply 0 9 A 1 2 A Icc Device...

Страница 26: ...n Magnitude of VOS for Complementary Output States IOS Output Short Circuit Current 250 mA IOFF Power off Leakage Out enabled VIN 12V 14 20 A VIN 7V 20 11 Out disabled VIN 12V 0 03 1 VIN 7V 1 0 01 IOZ...

Страница 27: ...L Input Low Voltage 5 V IIN Input Current VIN 0 V or VIN VDD 1 A Note Vdd 5V unless specified otherwise Table 15 KY EXT CL RS232 input specifications Symbol Parameter Test condition MIN MAX Units VOH...

Страница 28: ...EXT CL unit is housed in a metal enclosure The exact dimensions of the enclosure are as shown in the images below Figure 14 External dimensions of the KY EXT CL Camera Link side panel Figure 15 Extern...

Страница 29: ...Link Range Extender over Fiber User Manual 28 Figure 16 External dimensions of the KY EXT CL enclosure box 8 2 Weight Each KY EXT CL unit weights 356g metal enclosure weights 235g Mechanical Specific...

Страница 30: ...ted industry standard and there are many Camera Link products on the market today 9 2 Fiber cables Optical fibers are widely used to permits transmission over longer distances and at higher bandwidths...

Страница 31: ...0G 10 Fiber cable KY FCA XX X Camera Link Cable KY CCL XX X Power supply 12V 36W KY_PWR12_36 Table 17 Ordering Information Please contact KAYA Instruments for exact Part Number or refer to our website...

Отзывы: