background image

2

K5 4910. K5plus 4911.

KaVo assumes no responsibility for damage
arising through:

• external influences (poor quality of the

media or inadequate installation)

• use of incorrect information
• improper use
• improperly performed repairs.

Repair and maintenance work - apart from
the activities described in these instructions
for use - may be performed only by quali-
fied technical personnel.

In the event of modifications by third par-
ties, the approvals become null and void.
KaVo recommends using only original
spare parts for operation and for repair.

A 1.3 Precautions

Safe operation and protection of the unit are
ensured only through proper use in accor-
dance with the instructions for use and
using the tools approved for the purpose.
The following should also be observed:

• the tool manufacturer's instructions, 
• the work safety regulations,
• the accident prevention regulations.

!

Each time before switching on, check the

set speed.

!

Observe the permissible maximum speed

and maximum pressure of the tools
(according to tool manufacturer's
instructions).

!

Use safety screens when working with

rotating tools.

!

To avoid danger through accidental

switching on, place the handpiece on a
suitable shelf or tool support.

In the event of an unsatisfactory condition
of the unit or improper use, e.g.:

• unsuitable tools
• tool shafts not manufactured according to

DIN-ISO

• improper use or use not in accordance

with the purpose

• unapproved speeds for tools used
• incorrect clamping of the tools in the

chuck

• insufficient retaining force of the chuck

(wear, soiling, failure to follow the prod-
uct care instructions for the chuck system,
etc.)

• different sizes of tool shaft and chuck 
• lack of regular cleaning of the chuck
• failure to follow the maintenance instruc-

tions

• failure to comply with the accident pre-

vention regulations (e.g. failure to use
safety screens, safety devices, handpiece
supports, etc.)

• failure to take into account signs of wear

and damage

• tool shafts which have slipped out (poten-

tial danger = bending of the tool shafts)

there is a danger of injury and damage to
material and unit, e.g. due to:

• Bending of the tool shafts
• Accidental withdrawal of the tools from

the chuck

• Breaking or splintering of the tool.

Please note that the EC Directive on
waste electrical and electronic equip-

ment applies to this product. Within Europe
therefore, this product must undergo special
disposal. For more detailed information
about this, please contact KaVo or your
specialist dental supplier.

A 1 User information

A 1.1 Meaning of the pictograms

Situations where failure to follow the
instructions may lead to danger,

damage to material or operating faults.

Important information for operator
and engineer.

Automatic mode

Automatic sequence

Close, screw in, 

fasten, etc.

Open, release, loosen

+

more, higher

-

less, lower

Continuous operation

Time, time sequence

Disconnect mains plug

A 1.2 Important information

The instructions for use should be
read by the user before starting up

the unit for the first time, in order to avoid
incorrect operation and other damage. If
other language versions are required,
please request these from your responsible
KaVo agent. Duplication and distribution
of the instructions for use (IU) require
KaVo's prior consent.

All technical data, information and proper-
ties of the product described in the IU cor-
respond to the state on going to press.

Modifications and improvements to the
product as a result of new technical devel-
opments are possible.

This does not imply any right to retrofitting
of existing units.

Содержание K5 4910

Страница 1: ...Operating Instructions K5 4910 K5plus 4911 Always on the safe side...

Страница 2: ...Hersteller manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Tel 0 73 51 56 0 Fax 0 73 51 56 14 88...

Страница 3: ...ta 3 A 2 Scope of delivery Accessory 4 A 3 Description 4 A 4 Commissioning 4 A 5 Operation 5 A 5 1 Inserting changing the tool 5 A 5 2 Operation 5 A 6 Maintenance 6 A 6 1 Weekly cleaning of chuck and...

Страница 4: ...k of regular cleaning of the chuck failure to follow the maintenance instruc tions failure to comply with the accident pre vention regulations e g failure to use safety screens safety devices handpiec...

Страница 5: ...eight approx 216 g with connecting cable approx 319 g Output power max 85 watt max 4 5 Ncm Voltage max 30V AC Speed range 1000 35 000 min 1 In the presence of extreme interfering high frequency fields...

Страница 6: ...cket wrench 0 411 0211 A 3 Description Cover 3 covers as spare parts included in care set Straight pin Grip tip K5 handpiece part fi K5 motor part Chuck A Chuck key B Clip C Cleaning brush D Key E Ass...

Страница 7: ...changing the tool Closing the chuck Turn handpiece part and motor part fi in the direction of the arrow as far as they will go A 5 2 Operation If the workplace is unsuitably illumi nated a stroboscop...

Страница 8: ...kly cleaning of chuck and handpiece part Removing the chuck Remove previously used tool or straight pin from the chuck and take off cover 3 covers as spare parts in the care set Push straight pin into...

Страница 9: ...of arrow and remove clip Completely unscrew grip tip Unscrew handpiece part from motor part fi Loosen threaded ring with socket wrench F note left handed thread hold rotor shaft on the key surface wi...

Страница 10: ...socket wrench F again note left handed thread Insert felt washer over spring washer and screw on grip tip Completely tight en grip tip by means of clip B Screw handpiece part to motor part fi again T...

Страница 11: ...e incl plug devices and if necessary replace see A 6 3 C Diameter of tool shaft does not agree with chuck R Use chuck or tool with appropriate diameter C Chuck has become loose R Insert chuck correctl...

Страница 12: ...00 6360 0 674 8242 0 201 7066 0 222 4164 0 674 7382 0 674 8472 0 220 0058 0 223 0111 0 223 0396 0 674 8502 1 001 6751 0 224 7001 0 224 7048 0 674 7392 0 200 1045 0 223 0082 0 070 3305 7 mm 0 070 3274...

Страница 13: ...tion instructions corrosion contaminated media supply or chemical or electrical influences deemed abnormal or impermissible in accordance with factory specifications The warranty does not usually cove...

Страница 14: ...12 K5 4910 K5plus 4911 Declaration of Conformity...

Страница 15: ...13 K5 4910 K5plus 4911...

Страница 16: ...1 000 4576 RB 10 2008 GB 01 22 KaVo Dental GmbH D 88400 Biberach Riss Telefon 49 7351 56 0 Fax 49 7351 56 1488 Internet www kavo com...

Отзывы: