![Kaval BDA-1000 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/kaval/bda-1000/bda-1000_user-manual_658038005.webp)
l
Page 5
Kaval Telecom Inc.
DCM000000001
•
BLOCK DIAGRAM
REJECT FILTER #2
UPLINK DIRECTION
IN BUILDING
ANTENNA
HP
ANTENNA
COOLING FANS
VENTILATION
INPUT
AC POWER
TERMINAL BLOCK
VENTILATION
BDA
SUPPLY
28V POWER
CONTROLLER
ROOF TOP
HP
LP
LP
DOWNLINK DIRECTION
PA #1
REJECT FILTER #1
PA #2
BOOSTER #1
BOOSTER #2
Power and Control Connections
-------
RF Connections
____
BDA Controller :
An enclosed unit with microcontroller, LED indicators, buttons, and two-line display.
Temp Sense & Cooling Fans :
Controlled by the BDA Controller to ensure safe and reliable operation.
28V Power Supply :
Providing all DC Power, with optional Gell-Cell Battery Backup.
Duplexers :
Isolating Downlink and Uplink Frequencies, and coupling to antennas.
Reject Filters :
Installed if required to eliminate feedback.
Boosters :
High Gain (11 to 65 dB) Linear Amplifiers supplying up to 1 Watt of RF Power. The
basic gain is adjustable via the BDA Controller over a 33 to 65 dB range, and an
Automatic Gain Control (AGC) provides an additional 23 dB range.
PA Power Amplifiers :
Optional Linear Power Amplifiers providing 15 dB of additional gain, and up to 20 Watts
of RF Power.