l
Page 11
Kaval Telecom Inc.
DCM000000001
Fault Displays include ;
Up Boost Overcurrent
Up PA Overcurrent
Dn Boost Overcurrent
Dn PA Overcurrent
Up Boost Undercurr.
Up PA Undercurrent
Dn Boost Undercurr.
Dn PA Undercurr
Fan A Fail
Fan B Fail
Battery Low
Imminent Shutdown
Primary Power Fail
Overtemperature
Up Boost Internal
Up PA Internal
Dn Boost Internal
Dn PA Internal
External Fault
Controller Fault
Calibration Fail
Up Boost EEPROM
Dn Boost EEPROM
Uplink Overdrive
Downlink Overdrive
RS-232 Active
•
Menus
•
Main Menu
The Main Menu is entered by pressing the Select Button from any Status Display. If the Password is set to anything
but 000 (default), then a Password Entry Screen appears. The user uses the Adjust Buttons to select a digit, and
presses the Select Button to enter that digit. The cursor moves to the next digit and enters it. When the third digit is
entered, and the Password is correct, the Main Menu becomes available. If an incorrect Password is entered, then the
message “Wrong Password” appears for a few seconds and the user must start again. If the Password is set to 000
(disabled) the Main Menu is available immediately.
Enter Password
4**
Main Menu entries are used to group
Functions
by category. The User selects the Category and a Sub-Menu appears
listing available Functions. While in the Main Menu, the top row of the display shows “Main Menu”, and the bottom row
shows the Sub-Menu headings as one scrolls through them. When a Sub-Menu is selected, the Sub-Menu heading
replaces the Main Menu heading in the top row, and the bottom row then shows the Sub-Menu entries. If no Buttons
are pressed for 5 minutes while in any Menu the Display reverts to the last Status Display.
Available main Menu entries are:
Gain
Uplink Booster
Uplink PA
Downlink Booster
Downlink PA
Temperature
Fans
Battery
Controller
Calibration