background image

 

 
N

ON

-C

ONTACT THERMOMETER

 

M

ODEL

:

 

KM-25 

0482 

Содержание KM-25

Страница 1: ...NON CONTACT THERMOMETER MODEL KM 25 0482 ...

Страница 2: ...ACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE 26 HOW TO TAKE A TEMPERATURE 26 FOR RELIABLE RESULTS 27 V USING YOUR KAUFMAN KM 25 THERMOMETER 27 VI DESCRIPTION OF THE KAUFMAN KM 25 THERMOMETER 28 VII FUNCTIONS 29 VIII SETUP MENU FUNCTIONS 30 OPTION BUTTONS 30 SETTING UP THE KAUFMAN KM 25 THERMOMETER 31 1 TEMPERATURE UNITS 31 2 TEMPERATURE VARIATION 31 3 EXIT SETUP MODE 31 4 DATA MEMORY 32 5 CHAN...

Страница 3: ...ter to extreme temperature conditions 50 C or 20 C Do not use the device in relative humidity of above 85 The infrared sensor lens is the most fragile part of the thermometer Do not touch the infrared lens with your fingers Clean the lens with a cotton swab moistened with rubbing alcohol 70 isopropyl alcohol Do not expose the thermometer to sunlight or water Do not use outdoors Never drop the devi...

Страница 4: ...eter it is essential to use the Kaufman KM 25 thermometer correctly to obtain reliable and stable results You are therefore advised to read the instruction manual and safety directions carefully before use 1 Greenes D Fleisher G Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants Arch Pediatr Adolesc Med 2001 155 376 III PRECAUTIONS BEFORE USE The Kaufman KM 25 thermometer is ...

Страница 5: ...erature DIFFERENT METHODS OF TEMPERATURE MEASUREMENT Core temperature Measuring core temperature is the most accurate way to measure body temperature and involves measuring the temperature of the pulmonary artery by means of a catheter which is fitted with a temperature sensor to measure the temperature in situ Oesophageal temperature sensors work on the same principle However these invasive measu...

Страница 6: ...rtery Despite its low sensitivity and weakness in detecting fever axillary temperature is recommended by the American Academy of Pediatrics as a screening test for fever in new borns Tympanic thermometry To obtain an accurate tympanic temperature it is crucial to use the correct technique The thermometer sensor should be placed close to the warmest part of the external auditory canal Incorrect aim...

Страница 7: ...ut any contact with the temporal artery This artery is close to the surface of this skin and therefore accessible and allows accurate measurement of temperature given a permanent and regular blood flow The temporal artery is linked to the heart by the carotid artery which is directly linked to the aorta and it forms part of the main trunk of the arterial system The efficiency speed and comfort of ...

Страница 8: ...ould be moderate Take note of physiological temperature variations which should be taken into account when reading the results temperature increases by 0 5C between 6am and 3pm On average women s temperature is higher by 0 2C Also women s temperature varies in relation to their ovarian cycle it rises by 0 5C in the second half of the cycle and in the early stages of pregnancy When sitting temperat...

Страница 9: ... for at least 15 minutes before use to allow automatic recalibration of the device V USING YOUR THERMOMETER 1 Install the batteries 2 Before first use or when inserting new batteries wait 10 minutes for the device to warm up 3 Aim towards the forehead see the following diagram for how to position the thermometer from a distance of 5 cm press the thermometer s measure button and the temperature wil...

Страница 10: ...Visiomed Kaufman KM 25 V 2 3 201012 10 21 VI DESCRIPTION OF THE KAUFMAN KM 25 THERMOMETER Infrared sensor LCD screen Measure button mesure Battery compartment Advanced configuration buttons ...

Страница 11: ...109 2 F LO is displayed for results below 32 9 C 89 6 F 5 Memory for the last 32 temperature readings 6 Measurement and display of ambient temperature Variable effective measurement range of 10 C to 40 C 50 0 F to 104 0 F 7 Temperature displayed in Celsius or Fahrenheit 8 Automatic power off power save OTHER APPLICATIONS In Surface mode the KM 25 can take the temperature of the bath bottle etc In ...

Страница 12: ...sure the ambient temperature of a room BODY BUTTON Press to enable BODY mode BODY mode measurement range from 32 9 C to 42 9 C SURFACE BUTTON Press to enable SURFACE mode SURFACE mode measurement range from 0 C to 100 C ROOM BUTTON Press to enable ROOM mode ROOM mode measurement range from 0 C to 100 C IMPORTANT surface temperature is different to internal body temperature Internal body temperatur...

Страница 13: ...rface or Room Press the PROG button for 3 seconds the screen will show C F Press the PROG button again and TOF will be displayed on the screen Press to increase variation by 0 1 C to reduce by 0 1 C Confirm selection by pressing the PROG button If you are not sure it is recommended to leave the total variation as 0 0 C default setting Following any significant change in the ambient temperature 10 ...

Страница 14: ...he measure button The thermometer switches off after 5 seconds 5 CHANGING BATTERIES Display When the LCD screen shows the icon the battery is empty Action Open the cover and replace the empty batteries taking care to observe the correct polarity Incorrect battery polarity could damage the device and invalidate the warranty Do not use rechargeable batteries use single use batteries only Do not disp...

Страница 15: ... Consumption 50mW 8 Precision Body mode In a normal environment 0 3 C Surface mode From 22 to 42 C 0 3 C Above these temperatures 2 C Room mode From 10 to 40 C 0 5 C above 40 C 2 C 9 Time taken per measurement 0 8s 10 Time for repeat measurement 0 2s 11 Length of infrared waves 5 14µm 12 Measurement distance 5 cm 10 cm 13 Automatic power off 20 seconds PRECISION OF THE KM 25 The Kaufman KM 25 ther...

Страница 16: ...r will not be used for an extended period of time Do not expose the thermometer to sunlight or water Impacts can damage the device XI SUPPLIED ACCESSORIES User Manual Quick user guide Warranty Card Protective case Batteries AAA XII TROUBLESHOOTING No response Check the batteries polarity usage The icon is displayed Change the batteries Check that the polarity is correct when replacing Incorrect po...

Страница 17: ...n ROOM mode Lo is displayed on the screen result obtained is below 32 9 C or 89 6 F The temperature reading is below the measurement range for the selected mode 32 9 C for BODY mode or 0 C in SURFACE ROOM mode Cause of Lo Message Advice Temperature reading affected by hair perspiration etc Make sure that the forehead is clear before taking a temperature reading Temperature reading affected by a dr...

Страница 18: ...stributor by any modifications undertaken any connection of equipment not approved by Kaufman or causes contrary to those written in the user manual or notice Moreover the present guarantee does not cover damage due to falls bad handling bad installations damage by fire floods lightning or any other natural disaster This guarantee does not cover the packing of the material the accessories the defe...

Страница 19: ...Visiomed Kaufman KM 25 V 2 3 201012 19 21 Purchase date Serial Number Retailer s seal This warranty Card will not be re emitted SN Date Stamp ...

Страница 20: ...ling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office or your hou...

Страница 21: ...AN Service clients 21 Avenue Victor Hugo 75116 Paris France Tel 0892 680 180 Fabriqué en Chine Made in China Bannex Limited 2910 Excellence Times Square Yi Tian Road FuTian CBD Shenzhen Chinau KAUFMAN IS A PATENTED AND A REGISTERED TRADEMARK 0482 M ARQUE ET M ODELE DEPOSES ...