Kaufman & Robinson, Inc. (KRI) warrants to the purchaser or end user of the equip-

ment it sells that such equipment will be free from defects in material and workman-

ship under normal use and service.  This warranty is for a period of two years from 

the date of original shipment F.O.B KRI’s facility, Fort Collins, Colorado. This war-

ranty is void if the equipment is not used, operated, and maintained in accordance 

with the manual accompanying the equipment.  KRI shall not be responsible for 

any direct or indirect loss or damage resulting from accident, negligence of a user, 

alteration, abuse, or misuse of the equipment.  Upon acceptance of this Limited 

Warranty, purchaser waives all warranties, guarantee, or remedies not speci

fi

 cally 

stated in this Limited Warranty.  This warranty does not cover ordinary wear and 

tear or expendable components.

KRI’s obligation under this Limited Warranty is, at KRI’s option, to repair or replace 

any defective equipment or parts of the equipment, without charge to the purchas-

er, which are returned, shipping prepaid, to the KRI facility, 1306 Blue Spruce, 

Unit A, Fort Collins, Colorado, 80524 USA.  For return or repair of equipment, 

purchaser must contact KRI for a Return Materials Authorization prior to shipment 

of the equipment to KRI.  If KRI has designated an Authorized Warranty Service 

Representative in the purchaser’s country, contact may be made with the Autho-

rized Warranty Service Representative and defective equipment may be delivered 

to such Authorized Warranty Service Representative to service warranty claims.  

This warranty is in lieu of all other warranties, expressed or implied, including the 

implied warranties of merchantability and 

fi

 tness for any particular purpose.  The 

purchaser acknowledges the purchaser is not relying in KRI’s skill or judgment to 

select or furnish equipment suitable for any particular purpose.

This Limited Warranty will be construed in accordance with the Uniform Commer-

cial Code as adopted by the State of Colorado.

This warranty does not cover expendable parts; examples of expendable parts are 

as follows:

Alumina Insulators, Filaments, Re

fl

 ectors, Gas Line Isolator, Vacuum Cables and 

fuses.For Service or Repair, contact KRI:

Содержание DC3005

Страница 1: ...nson Inc 1330 Blue Spruce Drive Fort Collins Colorado 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com Copyright 2011 by Kaufman Robinson Inc All rights reserved No part of this pub...

Страница 2: ...TION AND INSTALLATION 2 1 2 2 Inventory 2 1 2 3 Physical Description 2 1 2 3 1 Front Panel 2 1 2 3 2 Rear Panel 2 2 2 4 Installation 2 2 2 4 1 Mounting 2 2 2 4 2 Cooling 2 2 2 4 3 Electrical connectio...

Страница 3: ...ww ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Figures Fig 2 1 Discharge Power Supply front panel 2 4 Fig 2 2 Discharge Power Supply rear panel 2 5 Tables Table 1...

Страница 4: ...485 High Speed Serial link for proprietary communications with KRI Controllers Fan on Demand cooling with thermal shutdown protection Front panel selectivity for local remote mode 1 2 Safety Caution O...

Страница 5: ...e for the Discharge Power Supply is 85 275 volts ac single phase at 50 60 Hz The maximum input current to the unit is electronically limited to 28 amps RMS Operation at lower line voltages may be limi...

Страница 6: ...30 Blue Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Table 1 1 Maximum Power Volt...

Страница 7: ...ny damage has occurred contact Kaufman Robinson Inc in addition to the ship ping company to report any damage see Warranty section 5 Retain packaging materials for shipment of the Power Supply Invento...

Страница 8: ...igure 2 2 shows the back panel of the Discharge Power Supply An RS 232 connection is provided on the back panel of this Power Supply for remote operation RS 232 connection at the back panel utilizes a...

Страница 9: ...s purchased with an Ion Source and Fila ment Power Supply interconnecting cables are provided Information regard ing installation of these connecting cables can be found in the Ion Source Filament Cat...

Страница 10: ..._____________ Copyright 2011 by Kaufman Robinson Inc 1330 Blue Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC30...

Страница 11: ...Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 163 7 21 1 167 7 21 Input Power RS...

Страница 12: ...pply will be in Standby with the Dis charge Amps and Volts Setpoints displayed The Setpoints that are displayed will be the last setpoints used before the supply was switched OFF If the last operation...

Страница 13: ...lts Discharge Amps display Displays the discharge current setpoint and run val ues in amps When the yellow setpoint indicator below the display is illuminated the setpoint value is displayed When the...

Страница 14: ...of methods Some type of terminal or communications program or programming can be used for controlling this unit Some examples of programs that can be used are Hyper Terminal provided with Microsoft Wi...

Страница 15: ...the unit is functioning normally or a number that corresponds to the front panel help codes as described in diagnostics section 4 MEASure CURRent or MEAS CURR Measure current query Returns the DC out...

Страница 16: ...e return NOTE If either VX command is zero the unit will go to standby 3 2 4 Operational sequence Using a terminal program configured for the communications settings previ ously mentioned input the fo...

Страница 17: ...t VA0 then press the enter key The out put will drop to zero and the Standby LED will be illuminated Output Current Monitoring of the output current can be done using the following command Input RD0 t...

Страница 18: ...Supply for connection to the analog interface The pin descriptions for the interface are given below in table 1 There is a button on the front panel that can be used to switch from remote to local co...

Страница 19: ...on nected to common The shutdown is deactivated when 5 volts is applied or no contact is made Remote shutdown is indicated on the front panel when activated 15 Auxiliary 5 volts DC 200 mA max Also ava...

Страница 20: ...ruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Table 3 4 Interlock connections Pin Nu...

Страница 21: ...gas bottle to the ion source Power must be removed from the Power Supplies prior to performing maintenance on the Ion Source 4 2 Diagnostic Table The following table may be used to assist in determin...

Страница 22: ...e PC Shows up only in re mote RS 232 operation Display says HLP 8 for 5 seconds Informational display only No action taken on unit operation Unit recovers from error condi tion if the problem goes awa...

Страница 23: ...ts KRI s obligation under this Limited Warranty is at KRI s option to repair or replace any defective equipment or parts of the equipment without charge to the purchas er which are returned shipping p...

Страница 24: ...oblem encountered or the item to be returned Product Serial number Detailed description of problem Date of purchase Name and address of company Contact person If return to KRI is required you will be...

Отзывы: