background image

LIMITED WARRANTY                                                                                      5-1

_______________________________________________________________________

Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524
Tel: 970-495-0187, Fax: 970-484-9350, Internet: www.ionsources.com

DISCHARGE POWER SUPPLY MANUAL

MODEL DC3005, MODEL 30010, MODEL 15012

5 LIMITED WARRANTY

Kaufman & Robinson, Inc. (KRI) warrants to the purchaser or end user of the equip-

ment it sells that such equipment will be free from defects in material and workman-

ship under normal use and service.  This warranty is for a period of two years from 

the date of original shipment F.O.B KRI’s facility, Fort Collins, Colorado. This war-

ranty is void if the equipment is not used, operated, and maintained in accordance 

with the manual accompanying the equipment.  KRI shall not be responsible for 

any direct or indirect loss or damage resulting from accident, negligence of a user, 

alteration, abuse, or misuse of the equipment.  Upon acceptance of this Limited 

Warranty, purchaser waives all warranties, guarantee, or remedies not speci

fi

 cally 

stated in this Limited Warranty.  This warranty does not cover ordinary wear and 

tear or expendable components.

KRI’s obligation under this Limited Warranty is, at KRI’s option, to repair or replace 

any defective equipment or parts of the equipment, without charge to the purchas-

er, which are returned, shipping prepaid, to the KRI facility, 1306 Blue Spruce, 

Unit A, Fort Collins, Colorado, 80524 USA.  For return or repair of equipment, 

purchaser must contact KRI for a Return Materials Authorization prior to shipment 

of the equipment to KRI.  If KRI has designated an Authorized Warranty Service 

Representative in the purchaser’s country, contact may be made with the Autho-

rized Warranty Service Representative and defective equipment may be delivered 

to such Authorized Warranty Service Representative to service warranty claims.  

This warranty is in lieu of all other warranties, expressed or implied, including the 

implied warranties of merchantability and 

fi

 tness for any particular purpose.  The 

purchaser acknowledges the purchaser is not relying in KRI’s skill or judgment to 

select or furnish equipment suitable for any particular purpose.

This Limited Warranty will be construed in accordance with the Uniform Commer-

cial Code as adopted by the State of Colorado.

This warranty does not cover expendable parts; examples of expendable parts are 

as follows:

Alumina Insulators, Filaments, Re

fl

 ectors, Gas Line Isolator, Vacuum Cables and 

fuses.For Service or Repair, contact KRI:

Содержание DC15012

Страница 1: ...inson Inc 1330 Blue Spruce Drive Fort Collins Colorado 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com Copyright 2011 by Kaufman Robinson Inc All rights reserved No part of this publication may be reproduced without written permission June 2011 Version 1 ...

Страница 2: ...CTION AND INSTALLATION 2 1 2 2 Inventory 2 1 2 3 Physical Description 2 1 2 3 1 Front Panel 2 1 2 3 2 Rear Panel 2 2 2 4 Installation 2 2 2 4 1 Mounting 2 2 2 4 2 Cooling 2 2 2 4 3 Electrical connections to ion source and discharge power supply 2 3 2 4 4 Electrical AC input 2 3 3 OPERATION 3 1 3 1 Local Mode 3 1 3 2 Remote Mode RS 232 3 2 3 2 1 Direct RS 232 connection from computer to discharge 3...

Страница 3: ...www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Figures Fig 2 1 Discharge Power Supply front panel 2 4 Fig 2 2 Discharge Power Supply rear panel 2 5 Tables Table 1 1 Maximum Power Voltage and Output 1 3 Table 2 1 Inventory List 2 1 Table 3 4 Analog connections 3 7 Table 3 4 Interlock connections 3 9 Table 4 1 Help codes and error messages for the Discharge Pow...

Страница 4: ...S485 High Speed Serial link for proprietary communications with KRI Controllers Fan on Demand cooling with thermal shutdown protection Front panel selectivity for local remote mode 1 2 Safety Caution Only technically qualified personnel should install maintain and troubleshoot the equipment described herein Lethal voltages and currents can be developed within the Power Supply therefore the Power S...

Страница 5: ...ge for the Discharge Power Supply is 85 275 volts ac single phase at 50 60 Hz The maximum input current to the unit is electronically limited to 28 amps RMS Operation at lower line voltages may be limited by outlet capacity and or circuit breakers 1 3 4 DC Output The maximum output for the DC30010 model of this Power Supply is 300 VDC and 10 amps Operation at this level is limited by thermal prote...

Страница 6: ...330 Blue Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Table 1 1 Maximum Power Voltage and Output Model Maximum Power Maximum Voltage Maximum Current 3005 1500 W 300 V 5 A 30010 2000 W 300 V 10 A 15015 2000 W 150 V 15 A ...

Страница 7: ...any damage has occurred contact Kaufman Robinson Inc in addition to the ship ping company to report any damage see Warranty section 5 Retain packaging materials for shipment of the Power Supply Inventory the contents shipped to determine completeness of the order 2 2 Inventory The following items are shipped with each Power Supply Table 2 1 Inventory List Quantity Desciption Part Number 1 Discharg...

Страница 8: ...Figure 2 2 shows the back panel of the Discharge Power Supply An RS 232 connection is provided on the back panel of this Power Supply for remote operation RS 232 connection at the back panel utilizes a DB 9 connector The RS 485 is for KRI autocontroller A ground stud is provided on the rear panel of this unit for grounding the chassis of the Power Supply Analog connections utilizing DB 25 female c...

Страница 9: ...as purchased with an Ion Source and Fila ment Power Supply interconnecting cables are provided Information regard ing installation of these connecting cables can be found in the Ion Source Filament Cathode Version Controller Manual If the Discharge Power Supply was purchased as a stand alone unit contact Kaufman Robinson Inc for cabling requirements 2 4 4 Electrical AC input The Power Supply has b...

Страница 10: ...______________ Copyright 2011 by Kaufman Robinson Inc 1330 Blue Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 163 7 21 1 167 7 21 Fig 2 1 Discharge Power Supply front panel ...

Страница 11: ...e Spruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 163 7 21 1 167 7 21 Input Power RS 323 Remote RS 485 Remote Analog Remote Air vents Ground Terminal Positive Terminal Negative Terminal Interlock Fig 2 2 Discharge Power Supply rear panel ...

Страница 12: ...upply will be in Standby with the Dis charge Amps and Volts Setpoints displayed The Setpoints that are displayed will be the last setpoints used before the supply was switched OFF If the last operation was with Remote control then the Power Supply will be in Remote when switched ON In this case the supply will respond to the remote commands in effect when switched ON Power Limit indicator Indicate...

Страница 13: ...olts Discharge Amps display Displays the discharge current setpoint and run val ues in amps When the yellow setpoint indicator below the display is illuminated the setpoint value is displayed When the green run indicator is illuminated the run value is displayed Setpoint indicator Indicates when the setpoints are being displayed on the Digital Displays When the yellow setpoint indicator below the ...

Страница 14: ... of methods Some type of terminal or communications program or programming can be used for controlling this unit Some examples of programs that can be used are Hyper Terminal provided with Microsoft Windows systems and LabviewTM by National InstrumentsTM Consult the user guide for installation and operation of the software that you plan on using for use of that program 3 2 2 Communications setting...

Страница 15: ...f the unit is functioning normally or a number that corresponds to the front panel help codes as described in diagnostics section 4 MEASure CURRent or MEAS CURR Measure current query Returns the DC output current in amps with three decimal places MEASure VOLTage or MEAS VOLT Measure voltage query Returns the DC output voltage in volts with three decimal places SOURce CURRent or SOUR CURR Input the...

Страница 16: ...ge return NOTE If either VX command is zero the unit will go to standby 3 2 4 Operational sequence Using a terminal program configured for the communications settings previ ously mentioned input the following commands in the defined sequence User Inputs are shown with quotations to designate the exact command the user must input the quotation marks should not be input into the terminal program Dur...

Страница 17: ...ut VA0 then press the enter key The out put will drop to zero and the Standby LED will be illuminated Output Current Monitoring of the output current can be done using the following command Input RD0 then press the enter key This reads a decimal number from 0 4095 that can then be converted to the cor responding output current To convert the decimal number to the output current divide the returned...

Страница 18: ... Supply for connection to the analog interface The pin descriptions for the interface are given below in table 1 There is a button on the front panel that can be used to switch from remote to local control There is also a two pin Molex connector on the back panel labeled INTERLOCK The pin descriptions for the interlock are also given below in table 3 4 1 Table 3 4 Analog connections Pin Number Des...

Страница 19: ...on nected to common The shutdown is deactivated when 5 volts is applied or no contact is made Remote shutdown is indicated on the front panel when activated 15 Auxiliary 5 volts DC 200 mA max Also available at pin 13 and 25 16 Common 17 Common 18 Over Temperature Output A 5 volt output indicates over tem perature 5 kΩ source impedance 19 Discharge Voltage Monitor Outputs 0 to 5 volts for 0 to maxi...

Страница 20: ...pruce Drive Fort Collins CO 80524 Tel 970 495 0187 Fax 970 484 9350 Internet www ionsources com DISCHARGE POWER SUPPLY MANUAL MODEL DC3005 MODEL 30010 MODEL 15012 Table 3 4 Interlock connections Pin Number Description 1 Active Low Interlock Connect to common Interlock pin 2 to enable the Discharge Power Supply 2 Interlock Return Common ...

Страница 21: ...e gas bottle to the ion source Power must be removed from the Power Supplies prior to performing maintenance on the Ion Source 4 2 Diagnostic Table The following table may be used to assist in determining faults and corrective action for the Discharge Power Supply Table 4 1 Help codes and error messages for the Discharge Power Supply Help Code or Error Message Description Possible Causes and Corre...

Страница 22: ...he PC Shows up only in re mote RS 232 operation Display says HLP 8 for 5 seconds Informational display only No action taken on unit operation Unit recovers from error condi tion if the problem goes away Make sure all of the equipment has adequate grounding Hot Thermal Overload Internal temperature in the power supply is too hot Power supply is in STANDBY Leave the power supply turned on until the ...

Страница 23: ...nts KRI s obligation under this Limited Warranty is at KRI s option to repair or replace any defective equipment or parts of the equipment without charge to the purchas er which are returned shipping prepaid to the KRI facility 1306 Blue Spruce Unit A Fort Collins Colorado 80524 USA For return or repair of equipment purchaser must contact KRI for a Return Materials Authorization prior to shipment ...

Страница 24: ...roblem encountered or the item to be returned Product Serial number Detailed description of problem Date of purchase Name and address of company Contact person If return to KRI is required you will be given an authorization number and instruct ed where to send it _______________________________________________________________________ Copyright 2011 by Kaufman Robinson Inc 1330 Blue Spruce Drive Fo...

Отзывы: