KATU 500 Series Скачать руководство пользователя страница 2

01

www.katusensor.com

Purpose of product application

The 500 Series sensor (switch) has two switch outputs and one analog output.

The standards applied during development, manufacturing and configuration are listed in

 the CE Compliance and manufacturer declarations.

Standard

Our scope of delivery and service is subject to legal warranties and warranty periods.

Warranty clause

We guarantee that the functions and materials of the dual pressure switch meet the 

statutory requirements under normal operation and maintenance conditions.

Security of loss

Such as:

- Incorrect use,

- Incorrect installation

- Incorrect operation or operation in violation of the provisions of this operation manual.

No liability shall be assumed for any damage resulting therefrom or consequential.

Quality assurance

!

danger

The sensor (switch) can only be used in the specified application range.

The temperature range must be within the permissible range. Do not exceed the rated 

pressure and power load value.

Assembly, commissioning and operation must be carried out in accordance with 

applicable national and local safety instructions.

The switch is designed to be used as a safety device for pressurizing the system in 

accordance with "Pressure Equipment Directive 97/23 / EC(PED)".

Содержание 500 Series

Страница 1: ...500 series operation instructions Sensor and controller Flow pressure temperature level position...

Страница 2: ...onditions Security of loss Such as Incorrect use Incorrect installation Incorrect operation or operation in violation of the provisions of this operation manual No liability shall be assumed for any d...

Страница 3: ...sult in fatal injury danger An identifiable hazard Failure to comply may result in fatal injury and damage to equipment or plant parts warning It means a danger Non compliance may result in minor inju...

Страница 4: ...modes Switching function If the switch is higher or lower than the set switching limit SP rP its switching state is changed The following switch functions can be selected Hysteresis function normally...

Страница 5: ...e intended to protect users from dangerous situations and or prevent material damage In the operating instructions the severity of the potential risk can be indicated by the following signal words Ins...

Страница 6: ...output SP1 IO Link Analog output voltage or current Level 2 menu res factory data reset Hold down to restore factory Settings ou1 Switch 1 signal Factory default is HNO Hysteresis function HNO normall...

Страница 7: ...changed At the press of a button the value increases Hold the button down and the value will keep changing ds2 OUT2 s opening delay The factory default is 0s Hold down or for at least 1s After 1 secon...

Страница 8: ...connecting cable is damaged Do not use any sharp hard objects to make entries The key may be damaged by something sharp and hard caution Two way switch one analog 12 30VDC PNP Analog quantity 1 2 4 5...

Страница 9: ...he button down and the value will keep changing rp2 Switch 2 Reset value Factory default value is SP2 0 5 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a...

Страница 10: ...y The factory default is 0s Hold or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases Hold the button down and the value will keep changing d...

Страница 11: ...on the value increases Hold the button down and the value will keep changing H0 The maximum value of system measurement history Hold down or for at least 1s After 1 second The setting value can be cha...

Страница 12: ...ill keep changing daa Display refresh time analog 0 1s factory default is 0 01 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases...

Страница 13: ...12 www katusensor com Display menu Display menu Level 1 menu Level 2 menu The one circuit switch does not have this function...

Страница 14: ...13 www katusensor com Display menu Level 2 menu No analog model does not have this function...

Страница 15: ...g process data flow IO Link communication and display Factory default 0 06 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases Hol...

Страница 16: ...Katu Electronic Kunshan Co Ltd The phone number is 400 150 8815 Website www katusensor com Factory No 1120 Jinyang East Road Kunshan City Suzhou City...

Отзывы: