TECHNICAL
SPECIFICATION
Static lines
Kattsafe static lines provide continuous attachment through intermediate connections points when using the a traveller,
providing efficient fall protection for multiple users. System design, supply, layout, installation and certification by a Kattsafe
approved installer, as per the manufacturer’s installation instructions and current standards.
Materials
Stainless steel profiled plate assembly including: end
stanchions, intermediates, corners, cable and connection
devices.
Dimensions
– Attachment cable: 8mm (7 x 7 strand)
– Cable height off structure: 125 to 150mm
Fixings (refer to installation manual)
– Metal fixing: M14 stainless steel stud fixing
– Concrete fixing: M12 mechanical concrete anchor
– Metal roof deck fixing: 8mm construction grade bulb type
rivets
Rating
– User weight limit: 120kg (user & equipment)
– Up to 4 users per line, determined by intermediate spacing
and roof pitch
– Maximum roof pitch: 30° (across slope), 15° (with slope)
– Support structure integrity, suitability and fixing method to
be assessed and determined by a competent person prior
to installation
– Must only be used with the approved Kattsafe traveller
device and harness system with energy absorber as per
AS/NZS1891.1:2009 and AS/NZS1891.4:2009
Compliance
Kattsafe static lines are designed to conform with
requirements of the Australian and New Zealand Standards
AS/NZS 5532:2013 AS/NZS/ISO22846 and AS/NZS1891 and
relevant codes of practices and guidelines.
Testing
Testing and performance based on requirements of
Australian and New Zealand Standards AS/NZS 1891 and
AS/NZS 5532.
Product warranty
10 years from date of purchase subject to correct
installation. Use and maintenance to be in accordance with
manufacturer’s specifications and recommendations. (This
excludes wearing parts).
Inspection and maintenance
Inspection and certification required every 12 months by
competent person in accordance with manufacturer’s
specifications and requirements of Australian and New
Zealand Standards AS/NZS 1891 and AS/NZS 5532. (Refer to
installation manual).
Important note
Failure to supply and/or install proprietary product in
accordance with above standards and codes, specifications
and instructions voids complete system certification and/or
warranty.