MAINTENANCE
CHECKLIST
The checklist below outlines key checking criteria required to ensure the safe use of this system. Any item of concern not shown
on the checklist must be noted on the maintenance report and brought to the attention of the workplace manager.
Items ticked PASS - YES means they conform with the required checking criteria and are suitable for normal use until the next
recertification date. System data plates must be updated showing current check date and next check date.
Item ticked PASS - NO means they do not conform to the required checking criteria. These items must be clearly tagged ‘ Do
Not Use’ and the required corrective actions put in place. The maintenance report must clearly document all non-conforming
criteria.
This system must be maintained by a competent height safety inspector trained in the safe use and maintenance of
this system.
Component
Inspection criteria
Pass Y/N
Corrective action
Completion date
End stanchion
Fixings to structure secure (min. 3 fixings to purlin, 9
fixings to roof deck).
All attachments/bolts secure.
No evidence of penetration seal deterioration.
No visible damage to unit/structure.
Energy absorber
Secure attachment to end stanchion.
Lock in pin circlip secure.
No ‘red’ excessive force indicator visible.
No visible damage to unit/structure.
Intermediate
Fixings to structure secure (min. 2 fixings to purlin, 8
fixings to roof deck).
All attachments secure.
No evidence of penetration seal deterioration.
No visible damage to unit/structure.
Corner
Fixings to structure secure (min. 3 fixings to purlin, 9
fixings to roof deck).
All attachments secure.
No evidence of penetration seal deterioration.
No visible damage to unit/structure.
Copyright, trademarks and product codes are property of Kattsafe. Patents and
design registrations may apply to these products.
14
Kattsafe / Static line / Operation manual
Содержание SL1