background image

3 / 4

General information on installation

Use of the amplifi er within a satellite reception system

The VWS 2500 amplifi er is used at the input to large multi-switch cascades or as a cascadable distribution network amplifi er 

for balancing the through losses of cables, branches or distributors in large distribution networks. It must be ensured that the 

level at the input lies between 50 and max. 80 dBµV, and the downstream multi-switches are not overloaded.

Setting the level for the amplifi er

It is best to use an antenna meter such as an MSK 130 to de-

termine the level. You can adjust the gain in 1 dB steps (see 

illustration on the right). Each amplifi er has its own adjusta-

ble attenuator available.

To compensate the slope of the attenuation, e.g. for long ca-

ble lengths, each sat amplifi er can be set to 2, 4 or 6 dB pre-

emphasis (see the illustration on the far right). The terrestrial 

amplifi er is set to a fi xed pre-emphasis value.

Connecting the amplifi er to other devices within the sat 

reception system

The quickest and easiest connection, for instance to a 

through multi-switch, is achieved using the optional EMU 250 

plug connector (illustration on the right). Here the devices are 

plugged into each other directly..

Installation instructions

    

The device described is intended solely for the installation in satellite receiver systems and may only be instal-

led by trained specialist personnel.

Any other use, or failure to comply with these instructions, will result in voiding of warranty cover.

The equipment may only be installed in dry indoor areas. Do not install on or against highly combustible mate-

rials.

The equipment must be provided with an earthing wire (Cu, at least 4 mm2).

The safety regulations set out in the current EN 60728-11 and EN 62368-1 standards must be complied with.

Fasteners for concrete substrates and masonry: 4 suitable plugs and associated screws with half-round or 

cylindrical head, outer thread diameter 4.5 - 5 mm, head diameter ≥ 9 mm and a screw length ≥ 30 mm 

For other types of wall, use the appropriate screws or screw-dowel systems, which off er the same or better 

fastening

Connector: RF plug 75 Ω (series F) to EN 61169-24.

Unused subscriber ports should be closed off  with 75 Ω resistors (e.g. EMK 03).

Risk of damage to property!

An inner cable conductor with a diameter greater than 1.2 mm, or the presence of burrs may damage the device 

inputs/outputs beyond repair.

Max. 2 mm

excess length

Clamping torque

max. 3.4 Nm

(danger of over-

winding)

Diameter

0.6 - 1.2 mm free of burrs

If the devices are further apart from each other, the use of high-quality coaxial cables (with 

very high screening values) such as LCD 111 is recommended. Where possible, use high-

quality F-type connectors as crimped connectors (illustration on the right) or as compression 

connectors (see the Kathrein catalogue Satellite and terrestrial reception antenna systems).

When using coaxial cables, take particular care to ensure correct assignment of the inputs 

and outputs to each other. The V low output from the amplifi er must be connected to the 

V low input of the multi-switch, etc.

Содержание VWS 2500

Страница 1: ...tiviert Schalterstellung KPS OFF Abb A Merkmale VWS 2500 20510098 Sat ZF Verteilsystem Multischalter Verteilnetzverst rker geeignet f r DVB T T2 42 5 134 205 177 148 A B Der Vertical Low Verst rkerzug...

Страница 2: ...nach EN 60728 3 4 60 dB IMA nach EN 60728 3 5 nach EN 60728 3 60 dB CTB CSO CENELEC Raster Warnung Lebensgefahr durch elektrische Spannung Nicht ffnen oder am Ger t manipulieren Bei Arbeiten an der An...

Страница 3: ...sanlage Der Verst rker VWS 2500 wird am Eingang gr erer Multischalterkaskaden oder als kaskadierbarer Verteilnetzverst rker zum Ausgleichen von Kabel Abzweiger oder Verteiler Durchgangsd mpfungen in g...

Страница 4: ...en Erdungsdraht von mindestens 4 mm2 Quer schnitt Verwenden Sie zum Erden des Ger ts die am Ger t vorhandene Erdungsschraube Jedes Ger t der Empfangsanlage muss geerdet werden Anlagenbeispiele symboli...

Страница 5: ...switch setting KPS OFF Fig A Features Sat IF distribution system Multi switch distribution network amplifier The vertical low amplifier unit is provided with a DC bypass so that the signal for Kathrei...

Страница 6: ...5 3 35 dB IMA to EN 60728 3 4 60 dB IMA to EN 60728 3 5 to EN 60728 3 60 dB CTB CSO CENELEC raster Warning Risk of fatal electric shock Do not open or tamper with the unit When working on the system a...

Страница 7: ...these instructions will result in voiding of warranty cover The equipment may only be installed in dry indoor areas Do not install on or against highly combustible mate rials The equipment must be pr...

Страница 8: ...V high H high V low H low 1 4 3 6 5 8 7 18V Power OFF Saving ON 2 Terr V high H high V low H low 1 4 3 6 5 8 7 Power Saving 2 Terr V high H high V low H low 1 4 3 6 5 8 7 Power Saving 2 Terr V high H...