Menus are available for editing the TSID and the ONID. The values can be modi
fi
ed by selecting the corresponding “orig” entry
using the “<” or “>” buttons and setting them to the “edit” value by using the “+” or “-” buttons. The current values of the TSID
and ONID from the processed transport stream are displayed in hexadecimal notation. In the “edit” setting you can modify the
values of the corresponding IDs. To do this, select the value using the “>” button. Use the “+” or “-” button to change the current
value in ± 1 increments. Alternatively you can also select numeric setting mode by pressing the
button. In numeric mode
each digit can be modi
fi
ed by pressing the “+” or “-” buttons in ± 1 increments. All IDs should be entered in hexadecimal format.
Possible values are “00h” to “FFh” for the OID and “0000h” to “FFFFh” for the TSID and the ONID.
Note:
Only experienced users should modify the TSID or ONID. If several channels (services) of a SAT transport stream
are distributed to multiple QAM transport streams, it is possible that the receiver cannot automatically detect all
channels because in this case the uniqueness of the TSID / ONID pair is lost. In this case please proceed as follows:
• Preferably the ONID should be modi
fi
ed. If possible, set it to a value between FF00h and FFEEh. This range is reserved
for private use and is not used by public network operators.
• If the channel search is unsuccessful despite the ONID adjustment, the TSID can be modi
fi
ed. Please ensure that all
TSIDs in a system are adjusted to guarantee uniqueness for each transport stream.
This sub-menu can be exited only when the cursor is on the “OID” parameter. To do this, use the “<” and “>” buttons to select “OID” and
press the “Sub-menu” button
to return to the main menu.
Note:
•
A description of extended functions such as “Cable NIT compilation”, “Logical Channel Number” assignment, etc. can be found in
the user instructions for the control elements UFG 300 and USW 30 that are required for implementing these functions.
2 Note