1 / 9

EXIP

414/E

20510103

SAT>IP server

Characteristics

Supports SAT>IP protocol  

Conforms to SAT>IP standard as per 

EN 50585 

Streams DVB-S-/S2 (HDTV) signals in 

an IP data stream 

Can be fed into different network types: 

LAN (also K-LAN, Powerline ...), WLAN 

integration via router, e.g. FRITZ!Box 

Four independent tuners, each for one 

data stream 

Web interface for configuration, 

 

administration and import 

of software updates

Status display via LED 

Can be configured for different clients 

1)

 :  

Tablet PCs, smartphones, notebooks, 

SAT>IP- capable receivers (z. B. UFS 

924) 

On/off switch 

Can be operated on different types of 

LNBs, multi-switches and single-cable 

multi-switches 

Supports standard switching signals: 

14/18 V, 22 kHz, DiSEqC™1.0,  

single-cable as per EN 50494 

Four Sat inputs; one Ethernet- 

RJ 45 connection 

For horizontal installation  

(e.g. like receivers) or on-wall installati-

on with the supplied mounting bracket

For indoor installation

High-efficiency plug-in power supply 

 

for voltage supply 

Cable shoe for earthing connection 

Support for wall mounting 

Instruction sheet 

1)

  Provided the required software/apps are installed on the device

Delivery scope

Vous trouverez la  

version française du 

document sur: 

Una versione italiana 

di questo documen-

to è reperibile su:

Encontrará la version 

española de este docu-

mento en la página:

www

.kathrein.com

 (Certified by SES ASTRA)

Содержание SAT IP 414/E

Страница 1: ...an verschiedenen Arten von LNBs Multischaltern und Einkabel Multischaltern m glich Unterst tzt die g ngigen Schaltsignale 14 18 V 22 kHz DiSEqC 1 0 Einkabel nach EN 50494 Vier Sat Eing nge ein Ethern...

Страница 2: ...ker 75 Serie F nach EN 61169 24 Stromf hrendes Ger t Nicht ffnen oder am Ger t manipulieren Bei Arbeiten an der Anlage immer Steckernetzteil aus der Steckdose ziehen F r die Ger teentw rmung muss frei...

Страница 3: ...i Schrauben 4 mm Kopfdurchmesser 7 mm montieren Alle Kabel anstecken anschrauben Ger t mit den F en von oben in die Wandhalterung einf hren Tischmontage keine Fixierung notwendig A B in Montagelage A...

Страница 4: ...rkl rt vor 1 Anschluss der RF Eing nge An einem Quad LNB oder Multischalter Sie k nnen die vier Eingangskabel wahlfrei anschlie en Das Ger t ist f r diesen Fall bereits vorkonfiguriert An einem Quatro...

Страница 5: ...kHz 2 Anschluss Netzwerk Der LAN Anschluss muss mit dem Heimnetzwerk verbunden werden Im Normalfall wird vom vorhandenen Router z B FRITZ Box automatisch eine IP Adresse vergeben Im Webinterface ist...

Страница 6: ...hnology Nach Eingabe des Passwortes exip gelangt man auf das Web Interface Eine ausf hrliche Anleitung f r das Web Interface finden Sie unter www kathrein de Grundeinstellungen Webinterface Der Datens...

Страница 7: ...zteil nicht an geschlossen Stecken Sie das Netzteil am Server an und verbinden Sie es mit dem 230 V Netz M gliche Fehlerursachen und deren Behebung Elektronische Ger te geh ren nicht in den Hausm ll s...

Страница 8: ...8 9 Anschlussbeispiele Symbolische Darstellungen UAS 584 IP IP IP IP IP EXIP 414 E berspannungs schutz KAZ 11 12...

Страница 9: ...sgangsspannung Horizontal V 17 5 bei 400 mA 19 bei 0 mA Ausgangsspannung Vertikal V 12 5 bei 400 mA 14 bei 0 mA Steuersignale 14 18 V 22 kHz 0 6 Vpp EN 61319 1 DiSEqC 1 0 EN 61319 1 A11 Einkabel Syste...

Страница 10: ...d on different types of LNBs multi switches and single cable multi switches Supports standard switching signals 14 18 V 22 kHz DiSEqC 1 0 single cable as per EN 50494 Four Sat inputs one Ethernet RJ 4...

Страница 11: ...lectrically live unit Do not open the unit or tamper with it When working on the system always unplug the mains plug from the wall socket There must be free circulation of air to dissipate the heat fr...

Страница 12: ...h two screws 4 mm head diameter 7 mm Screw on attach all cables Insert the device from above with feet pointing down into the wall support Table mounting no fastening required A B Note on mounting pos...

Страница 13: ...art up of the EXIP 414 1 Connection of RF inputs On a Quad LNB or multi switch You can connect the four input cables as desired The device is preconfigured for this On a Quatro LNB splitter or tap You...

Страница 14: ...0 22 kHz 2 Network connection The LAN connection must be connected to the home network Normal ly the existing router e g FRITZ Box will automatically assign an IP address On the Web interface Automati...

Страница 15: ...as Intel Tools for UPnP Technology The Web interface is accessed after entering the password exip You will find more detailed instructions for the Web interface on www kathrein de Basic settings Web...

Страница 16: ...it is not connected Insert the power supply unit into the server and connect it to the 230 V mains Possible causes of faults and their remedies Electronic equipment is not domestic waste it must be di...

Страница 17: ...8 9 Connection examples symbolic representation Over voltage pro tection KAZ 11 12 UAS 584 IP IP IP IP IP EXIP 414 E...

Страница 18: ...tage horizontal V 17 5 at 400 mA 19 at 0 mA Output voltage vertical V 12 5 at 400 mA 14 at 0 mA Control signals 14 18 V 22 kHz 0 6 Vpp EN 61319 1 DiSEqC 1 0 EN 61319 1 A11 Single cable system EN 50494...

Страница 19: ......

Страница 20: ...936 4910 VMWI 0215 DE GB Internet www kathrein com KATHREIN Werke KG Anton Kathrein Stra e 1 3 Postfach 10 04 44 83004 Rosenheim Deutschland Telefon 49 0 8031 184 0 Fax 49 0 8031 184 306...

Отзывы: