The transmitter (OSC 100) is equipped with loop-through outputs. Several transmitters are
cascaded.
AGC (Automatic Gain Control) provides for automatically controlled optical output level.
Therefore, no adjustment is required on the transmitter.
Installation and safety instructions
• The equipment described is designed solely for installation in satellite
receiver systems. Any other use or failure to comply with these
instructions will void the warranty or guarantee.
• The equipment may only be installed in dry areas indoors. Do not
install on or against highly combustible materials, near or over heat
sources or in contact with/near corrosive substances.
• The units must be connected to the equipotential bonding rail
(Cu, minimally 4 mm
2
).
• The unit must be installed by quali
fi
ed personnel in compliance
with the local security standards and regulations
.
The unit complies
to protection class II and thus need not be connected to the protec-
tive earthing of the mains supply.
• The safety regulations set out in the current EN 60728-11 and EN
60065 standards must be complied with.
• The units are solely designed for on-wall installation. Do not install
the device lying
fl
at or on its top, or operate it in this position. Suit-
able rawlplugs must be used to
fi
x the unit to the wall.
• Connectors: RF connectors 75
Ω
(series F) according to
EN
61169-24.
• Optical connectors: CLIK!
• Unused optical outputs are to be terminated with OTC 1
• All unused F-type connectors must be terminated with EMK 03, with
the exception of the 4 SAT inputs of OSC 100, which due to DC
voltage must be terminated with EMK 05.