background image

25 of 56

5.2.6  Laying the Cables and Connecting the Turntable

NOTICE
Risk of damage to cables from sharp edges and chafing points!

 

Do not lay cables across sharp edges.

 

Protect cables against possible chafing points.

1.  Connect the master coaxial cable (marked red) to the CAP converter and the slave coaxial cable to a second TV with 

a built-in receiver or a second receiver (if available).

Tip

If you do not use a second receiver, we recommend attaching the slave coaxial cable nonetheless, in case 
you might need it at a later time.

2.  Lay the turntable power supply cable (3-pin plug) to the battery. If necessary, use the power supply extension cable.
3.  Connect the master coaxial cable to the 

IF INPUT 

socket at the rear of the CAP converter. If necessary, use the coaxial 

extension cable.

5.2.7  Connecting the CAP Converter

WARNING
Risk of severe injuries due to cable fire

!

If you remove or bypass the fuse in the cable, it can cause cable fire.

 

Do not remove or bypass the fuse in the cable.

NOTICE
Risk of material damage due to incorrect supply voltage!

At the connecting point for the power cable, the voltage must not fall below 10.9 V even with a load of 12 A. 
Otherwise, optimum functioning can no longer be guaranteed.

 

Connect the CAP converter to no other power supply than 12 V.

 

Connect the earth pole of the CAP converter to the negative pole of the motor home or caravan battery.

NOTICE

Risk of material damage due to the absence of a blade fuse in the cable!

 

Protect the positive wire (red) of the power supply cable by using a 15 A blade fuse.

 

The fuse must be installed by a specialist.

 

If the fuse is blown, replace it by a fuse of the same rating (15 A).

 

Eliminate the cause of the fault.

NOTICE

Risk of malfunction and material damage due to reversed polarity!

When connecting the power cables, reversed polarity can lead to thermal overload and damage to compo-
nents when the equipment is powered up. If the earth of the ignition signal and the earth of the vehicle battery 
for the turntable do not have the same potential, the automatic antenna lowering does not function!

 

When connecting the power cables (CAP converter and turntable) to the vehicle electrical system, make 
sure that the poles are not reversed.

 

Make sure that the earth of the ignition signal and the earth of the vehicle battery for the turntable have the 
same potential.

Содержание MobiSet 3 Twin CAP 650

Страница 1: ...MobiSet 3 Twin CAP 650 Translation of the original operating manual CAP 650 English IMPORTANT Read carefully before use...

Страница 2: ...ons for Installation 22 5 2 4 Installing the CAP Converter on a TV Set 23 5 2 5 Installing the CAP Converter 24 5 2 6 Laying the Cables and Connecting the Turntable 25 5 2 7 Connecting the CAP Convert...

Страница 3: ...e Using the External Push button 49 13 4 1 Starting the Turntable 49 13 4 2 Moving the Turntable to the Park Position 49 13 4 3 Resetting the CAP System 49 13 5 Updating Software and Channel List 49 1...

Страница 4: ...ersione italiana delle istruzioni di montaggio dalla nostra rappresentanza1 piu vicina della sua citt oppure scaricarla dalla nostra web site2 E Para obtener la versi n espa ola de nuestro manual de i...

Страница 5: ...n cable 5 m F type female connector to F type male connector 1 x power supply extension cable 7 m for connection to the on board power supply incl blade type fuse 15 A roof duct with sealing gasket DE...

Страница 6: ...alignment of the satellite dish to receiver digital satellite signals The turntable is designed for use on stationary caravans or motor homes Any use other than that specified above will invalidate th...

Страница 7: ...sure that the roof and climbing aid are dry clean and non slip WARNING Risk of severe injuries due to moving parts especially risk of crushing Make sure that no one and in particular no children is in...

Страница 8: ...of of the vehicle by adhesive and is secured by additional screws Note that the curing of the adhesive sealant is temperature dependent It reaches its full strength only after approxi mately 2 days NO...

Страница 9: ...ter and turntable to the vehicle electrical system make sure that the poles are not reversed Supply Voltage Fusing WARNING Risk of severe injuries due to cable fire If you remove or bypass the fuse in...

Страница 10: ...er supply and to the ignition Checks before Commencing a Journey Before commencing a journey always lower the antenna into the horizontal position park position If the antenna has collided with a fixe...

Страница 11: ...a wireless hotspot function Using the external operating unit2 To change the satellite position press buttons to set the values Using a software update of the xml file with satellites created on the...

Страница 12: ...ing and Preparing NOTICE Risk of material damage during transportation Never carry the turntable on the planar antenna Keep the turntable in its cardboard box for transport on to the vehicle roof Unpa...

Страница 13: ...linations greater than 5 may lead to problems when searching for the satellite To ensure secure adhesion the height difference of the roof curve must not be more than 1 cm over a length of 2 m as othe...

Страница 14: ...n clearance 880 mm Park position Roof rail Roof attachments may be mounted within the hatched area High neighbouring attachments on the roof may lead to shadowing Area min 690 mm within which equipmen...

Страница 15: ...ircle Tip The size of the holes and the choice of fastening screws to be used not included in the scope of delivery depend on the type and thickness of the materials used in the roof structure If the...

Страница 16: ...e the roof duct Fig A and apply the adhesive sealant evenly to the underside of the roof duct flange Place the roof duct in the drilled hole and press it firmly against the roof of the vehicle Apply t...

Страница 17: ...ravel see Fig E Make sure not to step on the connectors or kink or crush the cables 3 Align the through holes on the turntable with the threaded holes on the mounting plate When lowering make sure tha...

Страница 18: ...OTICE Risk of material damage due to pulling the cables from the turntable Do not try to pull the cables from the unit 2 Place the turntable carefully on the mounting plate Make sure that the through...

Страница 19: ...KAsyl MS adhesive sealant to the spigot of the roof duct Insert the spigot into the hole and secure it from below with the knurled nut 3 Unscrew the screws x 6 10 AF from the mounting plate and remove...

Страница 20: ...which means that you do not have to place it where it is visible Therefore you can fit the CAP converter out of sight in any location e g on cupboard walls side walls or the base of storage compartmen...

Страница 21: ...unit monitors its own temperature in operation Continuous operation at temperatures higher than the recommended operating temperature can cause premature failure of the unit as a result of insufficien...

Страница 22: ...etween screw drill points Rear of the CAP converter Fron of the CAP converter 5 2 3 Important Instructions for Installation DANGER Danger to life from electric shock The wood screws could make contact...

Страница 23: ...k of a fatal electric shock Before starting any installation work disconnect all the units concerned from the mains Before installing the CAP converter on another electrical device check with the manu...

Страница 24: ...l damage from applying too much force when tightening the screws If you apply too much force when tightening the screws you can damage the screw sockets and the CAP converter casing or any cables alre...

Страница 25: ...oint for the power cable the voltage must not fall below 10 9 V even with a load of 12 A Otherwise optimum functioning can no longer be guaranteed Connect the CAP converter to no other power supply th...

Страница 26: ...connecting cable marked IGNITION allows you to connect to a circuit in the vehicle that is activated when the ignition key is turned and then carries a continuous 12 V supply This type of connec tion...

Страница 27: ...G Check the power rating of the circuit used with respect to the intended application 5 2 9 Connection Example for 12 V Battery Connection Fig G TV set 2 with a built in satellite tuner or satellite r...

Страница 28: ...preferably align your antenna to the position of the ASTRA satellite 19 2 East picture below left EUTELSAT HOTBIRD 13 East picture below right The spots for these satellites are shown below The inner...

Страница 29: ...6 screws which secure the turntable to the mounting plate 3 Place two wooden supports on the vehicle roof for protection 4 Place the turntable on the prepared wooden supports 5 Use the original packag...

Страница 30: ...reception If required change the polarisation setting of the satellite antenna as follows 15 if the satellite is more than between 15 and 20 west of the preferred reception range 15 if the satellite i...

Страница 31: ...ing operations Contact a technician or try to find a suitable person on the campsite 8 3 Setting Operations The following description assumes that the complete CAP unit has been properly assembled ins...

Страница 32: ...crews to a torque of 6 7 Nm see in Fig J 6 Leave the installation location 7 Reconnect the CAP converter to the power supply 8 Switch the CAP converter on using the on off switch The system is ready f...

Страница 33: ...sition yourself if you are unfamiliar with the necessary repair work Contact a technician or try to find a suitable person on the campsite It is necessary to recalibrate the antenna in an authorised w...

Страница 34: ...as to free the rocker from the engagement on the tapered shaft Screw an M12 x 40 screw minimum length 22 mm into this thread The rocker is pushed off the taper seating on the tapered shaft and the eng...

Страница 35: ...icle battery V 10 9 13 8 Power consumption from the 12 electrical system Inrush current Duration of the inrush current Satellite search TV reception Standby A ms A A mA typ 10 max 12 ca 200 typ 3 typ...

Страница 36: ...36 of 56 Technical Data 10 2 Dimensions in mm 118 3 118 3 282 153 6 Mounting plate 145 66...

Страница 37: ...37 of 56 Min recommended clearance 880 Rotary axis BAS 66 Roof duct Nut Clamping range 20 50 Mounting plate 145 146 incl mounting plate 211 701 248 400 10 323 442 38 17...

Страница 38: ...oxications SECTION 2 Hazards identification 2 1 Classification of the substance or mixture Classification according to Regulation EC No 1272 2008 The product is not classified according to the CLP reg...

Страница 39: ...for several minutes under running water If symptoms persist consult a doctor After swallowing Wash out mouth with water Contact a physician 4 2 Most important symptoms and effects both acute and dela...

Страница 40: ...e monitored at the workplace CAS No Designation of material Type Value Unit Not required Additional information The lists valid during the making were used as basis 8 2 Exposure controls Personal prot...

Страница 41: ...te Not determined Solubility in Miscibility with water Not miscible or difficult to mix Partition coefficient n octanol water Not determined Viscosity Dynamic Not determined Kinematic Not determined S...

Страница 42: ...available Additional ecological information General notes Water hazard class 1 German Regulation Self assessment slightly hazardous for water Do not allow undiluted product or large quantities of it...

Страница 43: ...has not been carried out SECTION 16 Other information This information is based on our present knowledge However this shall not constitute a guarantee for any specific product features and shall not...

Страница 44: ...List of Notified Chemical Substances CAS Chemical Abstracts Service division of the American Chemical Society LC50 Lethal concentration 50 percent LD50 Lethal dose 50 percent Flam Liq 3 Flammable liqu...

Страница 45: ...tal surfaces glass PVC polyester GRP painted and lacquered wood etc No adhesion on untreated polyethylene polypropylene and teflon In those cases where due to great thermal or physical loads especiall...

Страница 46: ...SO 37 ca 210 Shear stress DIN 53283 ASTM D1002 ca 2 5 MPa Alu Alu adh thickness 2mm test speed 50 mm min Tear propagation DIN 53515 ISO 34 ca 14 N mm Type C test speed 500 mm min Solvent percentage 0...

Страница 47: ...47 of 56...

Страница 48: ...650 starts from this page If despite studying these operating instructions you still have questions about getting started with the unit or using it correctly or if unexpected problems occur please co...

Страница 49: ...of malfunction and material damage from Overheating of the turntable motor If the turntable motor operates without interruption for longer than 20 minutes it can cause overheating of the motor None of...

Страница 50: ...T socket NOTICE Risk of material damage Do not interchange the cables 2 Make sure that the supplied 12 V connection cable is installed by a specialist dealer 1 Not included in the scope of delivery DE...

Страница 51: ...ing the on off switch 6 Switch the CAP converter back on The channel list is loaded when the CAP converter starts The LED status shows whether the channel list has been successfully downloaded or whet...

Страница 52: ...CAP converter to operate normally again Normal operation Green LED flashes slowly CAP is in the park position LED flashes 3 x then stops for a bit CAP is moving to a position e g to the park position...

Страница 53: ...AMENT AND THE COUNCIL dated 27th January 2003 concerning used electrical and electronic appliances it must be disposed of properly At the end of its service life take this unit for disposal at a desig...

Страница 54: ...54 of 56 Declaration of Conformity 15 Declaration of Conformity...

Страница 55: ...55 of 56...

Страница 56: ...www kathrein com sat kathrein de KATHREIN Werke KG Anton Kathrein Stra e 1 3 83022 Rosenheim Germany Phone 49 8031 184 0 Fax 49 8031 184 52360 936 5022 VMPT 0116 GB Subject to change...

Отзывы: