Type
EXR 561/ECO
Part no.
20510058
Subscriber connections
1 x 6
Inputs
1 x terr.
4 x Sat IF
Frequency ranges
MHz
5-862
950-2150
Connection loss, terr.
dB
1
-
Gain to the subscriber connection (SAT)
dB
-
7
→
12
Adjustable attenuator setting range (SAT, 1 dB steps)
dB
-
0-15
Horizontal/vertical isolation
dB
-
30
Operational level
dB
μ
V
-
93
Subscriber frequency/SCR address
Receiver 1
Receiver 2
Receiver 3
Receiver 4
Receiver 5
Receiver 6
MHz
1284/0
1400/1
1516/2
1632/3
1748/4
1864/5
Screening factor
dB
5-300 MHz > 85
300-470 MHz > 80
470-1000 MHz > 75
1000-2400 MHz > 55
Permissible supply voltage at the subscriber output
V
12-14
Max. power consumption
mA
190
Max. remote feed current
mA
200
Permissible ambient temperature
°C
-20 to +55
Connections
F
connectors
Dimensions (W x H x D)
mm
162 x 148 x 43
Packing unit/weight
Items/g
1/350
Technical Specifi cations
Problem
Possible cause
Solution
Multi-switch fails to switch
No control signal or
wrong control signal
from receiver
Check that there are no short circuits in the connection from the
receiver to the multi-switch. Check the receiver menu settings
(single cable mode!). Operating voltage on receiver output should
not be greater than 14 V
Multi-switch operates, but no
associated picture appears
Incorrect input cable
frequency
Check menu settings of all connected receivers.
Check that frequencies are assigned to one receiver only
Picture shows pixels whilst
another receiver is changing
over
Voltage at LNB too low
Use distributors with no diodes in conjunction with ESU 33/34.
Connect an NCF 18 power supply unit to the option DC socket
Possible causes of faults, and their remedies