background image

10 / 16 

 Connecting the CAP converter

    

The CAP converter V2 may only be operated with a supply voltage of 10.5 to 30.0 V. The earth connection of 

the CAP converter must be connected to the negative pole of the motor home or caravan battery. Discon-

nect the vehicle electrical system (main switch “Off ” or disconnect the positive pole from the vehicle elec-

trical system battery) before starting the following work.

Connect the master coaxial cable (of the turntable) or coaxial cable (of the HDS 166 plus/CAP 500M plus) to the F 

socket “Antenna” on the back of the CAP converter.

Connect the “TV/STB” connection of the CAP converter and a receiver or TV set with integrated satellite tuner using a 

coaxial cable.

Connect the supplied power cable (depending on the power supply available in your motor home or caravan, 12 V or 

230 V with mains adapter) to the “12V 2.0A” plug-in connection of the CAP converter.

Check the connections before you reconnect the on-board power supply.

Connections on the CAP converter

RESET

TV/STB

ANTENNA

-

+

12V      2,0A

ETHERNET

STATUS

CONTROL UNIT

950-2150MHz

14/18V 

400mA max.

22kHz

DE - 83022 Rosenheim

USB 2.0

5V        500mA max.

1

2

3

4

5

6

7 8

9

TV / STB  

 

Output satellite signal to TV/receiver

 ANTENNA   

Input satellite signal of Kathrein CAP/HDS

 RESET 

 

Reset button

 USB 2.0  

 

Type A USB port

 ETHERNET    

RJ45 network socket

 CONTROL UNIT  

Connection to pushbutton//HDS 50/HDS 52 RJ 12

 STATUS  

 

Status LED to indicate the operating status

 Power switch

 12V 2.0A  

 

Power supply

Functional instructions for connection to the on-board power supply

Problems may occur if the devices are connected to diff erent connection sockets or circuits/earth potentials. It is recom-

mended to connect the connection sockets of the turntable to the same cable. Check the current carrying capacity of 

the circuit used to ensure compliance with the intended application.

12V battery wiring diagram

12V

Battery

10,5 V - 15,5 V

red

black

Fuse 5A

The CAP converter must be protected by a 5 A fuse, which is to be connected between the red connection cable and the 

battery.

Содержание CAP Converter V2

Страница 1: ...1 16 Control Unit for Camping Caravan Reception Systems TV Live Instruction Manual CAP Converter V2 204500001...

Страница 2: ...ear panel of a TV set 9 Connecting the CAP converter 10 Functional instructions for connection to the on board power supply 10 12V battery wiring diagram 10 Connection example CAP x50 GPS 11 Connectio...

Страница 3: ...llite Low power consumption Intended Use The CAP converter V2 control unit is used to control the fully and semi automatic Kathrein camping satellite systems The control unit is designed for use on st...

Страница 4: ...tables easily and conveniently without having to switch on a receiver or TV set Selecting a satellite lowering the turntable to the park position and other functions can be called up via an intuitivel...

Страница 5: ...re that children do not insert any objects into the ventilation slots Cleaning Unplug the connection cable power supply unit before cleaning the unit Do not by any means open the device Do not insert...

Страница 6: ...ider it necessary provide a new manual for download at www kathrein ds com Repair Make sure that any repairs to the device are carried out by qualified personnel only Improper work on the device may i...

Страница 7: ...llation place Strain relieve the connecting cables Connections and fuses All connecting cables are connected to the rear of the CAP converter Viewed from the front there is a fuse inserted from the ou...

Страница 8: ...ntation supplied with the device to find out whether this is permissible and if so which aids screws etc are required may be used Using other screws If the supplied screws cannot be used due to the in...

Страница 9: ...due to overheating of the devices and fire Do not install the CAP converter between a TV set and a wall bracket The CAP converter may only be installed on the rear panel of a TV set if the TV has a s...

Страница 10: ...efore you reconnect the on board power supply Connections on the CAP converter RESET TV STB ANTENNA 12V 2 0A ETHERNET STATUS CONTROLUNIT 950 2150MHz 14 18V 400mAmax 22kHz DE 83022 Rosenheim USB2 0 5V...

Страница 11: ...50 separate control panel TV set 2 UFZ 132 Wi Fi Hotspot TV set 1 Slave coaxial cable Master coaxial cable Power supply cable Optional accesssories with satellite tuner control streaming Connection e...

Страница 12: ...ting the CAP Converter with CAP Systems or HDS 166 plus CAP 500M plus Plug the external Kathrein pushbutton included in the scope of supply into the RJ12 socket CONTROL UNIT on the CAP converter V2 se...

Страница 13: ...Automatic OTA over the air update of software channel lists and search transponders The CAP converter auto matically checks whether new software is available If new software is available it is automat...

Страница 14: ...the error so that the CAP converter can return to normal operation Normal operation Green LED flashes slowly CAP is in the park position LED flashes 3x followed by a short pause CAP is moving to the...

Страница 15: ...ery V 10 5 30 0 Power consumption at 230 V max typical operation standby W 14 12 0 2 LNB supply horiz vert V mA 14 18 max 400 Antenna 1 x F type connector TV STB 1 x F type connector Supported control...

Страница 16: ...e the satellite position open the app and go to Settings Satellite selection To use the app you will either need a LAN connection to the router or the UFZ 131 1322 WiFi USB adapter with wireless hotsp...

Отзывы: