![Katadyn Spectra Watermakers Catalina 340R Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/katadyn/spectra-watermakers-catalina-340r/spectra-watermakers-catalina-340r_installation-and-operating-manual_3608509033.webp)
33
If the system has been pickled, stored, or contains cleaning compounds, use the New System Startup procedure.
The system should be fully run tested before you leave port. If the location or weather prevents proper testing refer to
“
Testing with an Artificial Ocean.
”
1.
Check that the thru
-
hull inlet is open.
2.
Turn the product sample valve to the
SAMPLE
position.
3.
Turn the toggle switch on the feed pump module to
RUN MANUAL
.
4.
Start the system by pushing
‘
Start
’
and check for flow by inspecting the brine discharge and checking
for pressure on your analogue gauge. If there is no flow, open the pressure relief valve on the Clark
Pump to prime the system and bleed the air out of the feed pump.
5.
After 5 minutes, check the product water with your handheld salinity tester. When it is below 750 PPM,
divert the product into your tank by rotating the product sample valve handle 90 degrees.
6.
Run the system until you have filled your tank or have made enough to meet your requirements.
7.
Following your water making session, perform a freshwater flush.
Freshwater Flush (You should freshwater flush your watermaker after EVERY use.)
1.
Push the
Freshwater Flush
button on the remote panel.
2.
The freshwater flush solenoid will open and feed pump will come on, allowing pressurized freshwater
to flow through the system. Pressure will drop on the gauge, which indicates that the membrane is
flooded with fresh water.
3.
After a proper flush, the ppm of the brine discharge should be below 1000ppm.
You may now leave the system unattended for up to five days (30 with the Z
-
Ion) without further attention.
Remember that you need to run the system almost a half an hour to make enough water for a flush. You
may notice that the system output is higher while charging your batteries, as the machine is voltage
sensitive.
Normal Operation and Fresh Water Flush
Analog Gauge Panel
Remote Panel
3
-
Way Product
Sampling Valve
To Sample
To Tanks
In
Nominal Operating Parameters
Parameter
Minimum
Maximum
Product Quantity
13.5 GPH (51 LPH)
15.5 GPH (58 LPH)
Product Quality
>300ppm
750 ppm
Feed Pressure
80
-
100psi
110 psi (7.6 Bar)
Boost Pressure
15 psi (1.1 Bar) or Greater
Filter Condition
100%
Amp Draw
19A @ 12.5vdc
Содержание Spectra Watermakers Catalina 340R
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 14: ...14 Installation Notes ...
Страница 17: ...17 ...
Страница 20: ...20 ...
Страница 21: ...21 John Guest Super Speedfit Fittings ...
Страница 52: ...52 ...
Страница 55: ...55 ...
Страница 61: ...61 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used ...
Страница 63: ...63 Parts 1 ...
Страница 64: ...64 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Страница 68: ...68 ...
Страница 70: ...70 ...
Страница 73: ...73 ...