5
the unit needs to be stopped before the timer runs up, press “Ultrasonic frequency”
button.
NOTE: Do not run the cleaner continuously for more than one hour
3.
Temperature setting:
Press
“
temp/temperature-
”
shortly at a
time means time increase or reduce 1
℃
at a time, press and hold time switch
continuously will increase/reduce by 10
℃
. Usually, the best cleaning temperature is
within 40
℃
to 60
℃
.
4.
After time and heat setting, press “Heating” or “ultrasonic” button to start both
function. If press the “ultrasonic “ again , the ultrasonic function will stop , and the heating
function will stop at the same time. If want to keep heating, need to press “ heating”
button again.
5.
Degas mode
: work intermittently
,
i.e., 6s “ON” + 2s “OFF” working mode. It can
clean items deeply and efficiently.
6. Empty the tank and clean both the outside and inside of the cleaner with a clean
and dry cloth for next use.
NOTE: Do not pour water out until it’s cooling, because of hot water will hurt you
and also empty burn will damage the machine itself.
DIFFERENT WAYS OF CLEANING
Gennral Cleaning
—
use only water to clean under the temperature of about 50
℃
;
Enhanced Cleaning
—
add few drops of standard cleaning solutions, liquid soap, or
detergent, or any other non-acidic cleaning agents.
Extensive Cleaning--
removing tarnish, carbon & rust from non-plated metals, it is
recommended to use specific cleaning solution associated with ultrasonic cleaners.
The cleaning solution will deteriorate in effectiveness over time and use. It is important
to regularly change the fluid and carefully wash the inside of the cleaning tank in order
to preserve the effectiveness and longevity of the cleaner. Do not use corrosive or
WARNING
: Strong acid or alkaline cleaning solution will cause corrosion, rust and
even puncture of tank or machine body. To solve this problem, please dilute the solution
to mild PH or use a special tank made of a specific-graded stainless steel, For example:
use SUS304 tank.