INSTALLATION INSTRUCTIONS
© 2019 Kason Industries, Inc. IS-8600EZ-200 Rev 6 03/19
kasonind.com | 1.800.935.2766 | PAGE 13
8600EZ Power Drive
Single Doors and Bi-Parting Doors
Part Number: 8600*
Step 5
. Select fuse for desired voltage: Refer to fuse chart
Fig. 24
. Kason fuses may be ordered at the same time as the 8600EZ
Power Drive, as long as the voltage is known.
Fig. 23
Application
AC
Supply
DIN Rail Fuse
Fuse Rating
Type
Suggested
Model #
KASON P/N
Amps
Volts
Primary
115
L1 and L2
10
600
Slow Blow
KLKR 10
8600EZ0928
208
L1 and L2
6
600
Slow Blow
KLKR 6
8600EZ0929
230
L1 and L2
6
600
Slow Blow
KLKR 6
8600EZ0930
460
L1 and L2
3
600
Slow Blow
KLKR 3
8600EZ0931
575
L1 and L2
2
600
Slow Blow
KLKR 2
Secondary
S1
10
600
Slow Blow
KLKR 10
Accessories (AC)
UT1
1
250
Fast Blow
ABC-1-R
Accessories (DC)
UT3
1
250
Fast Blow
ABC-1-R
Battery Backup
BB
10
600
Slow Blow
KLKR 10
Note
: Model # refers to BUSSMAN for ABC series
Model # refers to LITTLEFUSE for KLKR and KLDR series
Fuse Installation
: Fuses will install correctly into fuse blocks only with the raised “button” end outward as fuse is inserted
into holder.
FROM GEAR
MOTOR
Step 6.
Wire gear motor power inside panel. Wire color
matches color of connector terminals. See
Fig. 23
(Step 1) for location of connectors.
Step 7.
Wire gear motor control. Wire color matches
color of connector terminals. See
Fig. 23
(Step 1) for
location of connectors.