11

Warranty Period: 5 years

Kasco® Marine, Inc. warrants this diffuser assembly to be free from defects in material or workmanship 

under normal use and service. The Kasco Marine, Inc. obligation under this warranty is limited to replacing 

or repairing free of charge any defective part within the warranty period. The customer shall pay shipping 

charges for returning the unit to Kasco or an Authorized Repair Center. 

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND ANY OTHER OBLI-

GATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE, INC. AND IN NO EVENT SHALL KASCO 

MARINE, INC. BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES. 

Warranty is void if: 

• 

The assembly is not maintained properly according to the maintenance recommendations supplied in 

this manual. 

• 

The assembly is damaged by unauthorized tampering. 

Warranty Claim Procedure

The best method for establishing warranty period is via the original receipt. Also, register the unit online at: 

www.kascomarine.com

. Once the warranty coverage has been established, the unit may be sent to any Kas-

co Authorized Repair Center for evaluation and repair. Please call Kasco at 715-262-4488 prior to shipping 

to receive any updated information and/or Repair Form, or call to locate your nearest Authorized Repair 

Center. You can also email Kasco at [email protected]

Please include the repair form received from Kasco or your local distributor with the shipment. If no repair 

form is available, include your name and physical address for return delivery of the repaired unit and a day-

time phone number and/or email address for correspondence regarding the warranty claim. Any expedited 

shipping method for the return of the unit is at the customer’s expense. Kasco will return units repaired 

under warranty at our expense via ground freight within the continental United States.  

WARRANTY

Please attach a repair form with the shipment. The repair form must include a name, physical 
address (for return delivery of the repaired unit), daytime phone number, and an e-mail address 
for correspondence regarding the warranty claim.

Any expedited shipping method for the return of the unit is at the customer’s expense. Kasco will 
return units repaired under warranty at our expense via ground freight within the continental 
United States.

Back to Contents

Содержание Robust-Aire

Страница 1: ... MANUAL 1 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Document number 772100 Document version 2021 1 0 DIFFUSER ASSEMBLY Robust Aire Assembly Installation Manual ...

Страница 2: ...2 4488 kascomarine com sales kascomarine com QUESTIONS Safety First 2 Suggested Tools Supplies 2 Installation Suggestions 2 Parts Included 3 Assembly Instructions 4 Installation Instructions 9 Replacement Parts 10 Warranty 11 Other Repairs 12 Repair Contact Form 13 ...

Страница 3: ...ding wearing a PFD Personal Flotation Device Consult a qualified electrician for electrical installation SAFETY FIRST Electrical Shock Hazard Electrical Shock Hazard SUGGESTED TOOLS SUPPLIES 7 16 socket wrench with shaft extension or 7 16 nut driver Adjustable wrench Flathead screw driver or 1 4 nut driver Retrieval ropes longer than the desired installation depth optional Marker buoy optional INS...

Страница 4: ...n Qty 1 Locknut 6 2 Carriage bolt 6 3 5 8 barb fitting 1 4 3 8 barb fitting 1 5 3 8 hose clamp 1 6 5 8 hose clamp 1 7 Edge guards 2 8 Substrate connector 1 9 Substrate riser 2 10 Tubing assemblies 2 11 Inlet check valve assembly 1 11 2 1 3 4 7 8 9 10 5 6 Back to Contents ...

Страница 5: ...tee fitting so the open end faces away from the center of the tubing loop Tighten until snug making sure the blue lines on both aeration tubing assemblies face the same direction and are parallel with the inlet check valve assembly Tighten a barb fitting into the check valve assembly The barb fitting size depends on the SureSink Tubing size Use an adjustable wrench to tighten the barb fitting to t...

Страница 6: ...te riser around the tee fitting Rotate up and secure the aeration tubing into the substrate riser 4 Repeat step 3 to attach both substrate risers to the assembly For best performance keep an equal amount of tubing on either side of substrate risers 5 Slide the substrate edge guards onto the connector plate as shown Back to Contents ...

Страница 7: ... 6 Rotate the entire assembly and set the tubes on a flat surface 7 Insert the six provided carriage bolts into the holes on the substrate connector plate and loosely tighten them down with the six provided lock nuts to temporarily hold them in place Back to Contents ...

Страница 8: ...xtender for the socket wrench ASSEMBLY INSTRUCTIONS CONT 9 Slide the provided hose clamp of the appropriate size onto the SureSink Tubing Feed the weighted tubing over the substrate connector leaving plenty of slack Make a generous loop and secure the tubing to the barb fitting with the hose clamp Tighten down the clamp with a flathead screwdriver or a 1 4 nut driver Back to Contents ...

Страница 9: ...on the barb fitting 5 8 strain relief 3 8 strain relief 11 On the other side of the connector plate press the weighted tubing into the remaining strain relief notch of the same size diagonal from the notch on the opposite side of the plate Ensure that the SureSink Tubing snaps into place in both correctly sized notches before installing the unit 3 8 SureSink 5 8 SureSink 3 8 SureSink 5 8 SureSink ...

Страница 10: ...al hole Installation rope Optional Step Once at the desired location thread a rope through the two retrieval holes on one side of the diffuser base Pull the rope through the holes until its midpoint is centered between the retrieval holes Slowly lower the diffuser until it reaches the bottom of the pond and tie the installation rope to a marker buoy Doing this will allow for easier maintenance in ...

Страница 11: ... 8 barb fitting 1 773013 4 3 8 barb fitting 1 773012 5 3 8 hose clamp 1 773008 6 5 8 hose clamp 1 773009 7 Edge guards 2 772032 8 Substrate connector 1 772031 9 Substrate riser 2 772030 10 Replacement tubes 2 772040 11 Inlet check valve 1 772033 12 Tee fitting 3 772221 13 Nipple 2 773003 1 2 3 4 5 6 7 8 9 13 12 11 10 Back to Contents ...

Страница 12: ... the unit may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information and or Repair Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local distributor with the shipment If no ...

Страница 13: ... a dollar amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore the unit as closely as possible to the condition in which we found it and ship at the customer s expense including shipping a...

Страница 14: ... used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility...

Отзывы: