manualshive.com logo in svg
background image

TEICH-AIRE MANUAL

2

Thank you for purchasing this Teich-Aire rocking piston oil-less compressor. It is manufactured to the 

highest standards using quality materials. Please follow all recommended maintenance, operational, and 

safety instructions, and you will receive years of trouble-free service.

IMPORTANT: PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE.

Rocking Piston Compressor

Model

Serial No.

Air Flow

cfm

Max pressure

psi

Voltage

V

Hz

Amp

Phase

Single

Kw

RPM

To avoid accidents, use only as described in this manual.

•  Pump only clean, dry air.

•  Operate at 32 °F – 104 °F (0 °C to 40 °C).

•  Protect the unit from dirt and moisture.

• 

Do not pump flammable or explosive gases or use in an environment that contains such gases.

• 

Protect all surrounding items from exhaust air. Exhaust air can become very hot.

•  Corrosive gases and particulate material will damage the unit. Keep free of any water vapor, oil-based 

contaminants, or other liquids.

•  This pump is oil-less and requires no lubrication.

Correct installation is your responsibility. Ensure 

proper installation conditions and installation clear-

ances for sufficient airflow.

•  Install the compressor in a clean, dry location.

•  Ensure the compressor is protected from dirt, 

moisture, and harmful elements of the outdoor 

environment.

•  Ambient air temperature (readings taken 4” away 

from any surface of the compressor) must not 

exceed 104 °F (40 °C).

•  Ensure that adequate ventilation and cooling air 

(flowing across the compressor) is available to 

keep the compressor from overheating, which can 

cause premature damage.

•  Mount the compressor to a stable, rigid operating 

surface. Using the provided shock mounts will 

reduce noise and vibration.

• 

Kasco offers a simple, durable bracket accessory 

that will allow you to easily mount the compressor 

to a wall, floor, or bench. Please contact your Kas

-

co distributor and ask for the compressor mount 

kit appropriate for the voltage of your compres-

sor (Part #771250 for 120V and Part #771260 for 

240V).

PRODUCT OVERVIEW

Important Product Use Information

Installation Requirements

WARNING

Disconnect electrical power at the circuit breaker 

or fuse box before installing this product.

Install this product where it will not come into 

contact with water or other liquids.

Install this product where it will be protected 

from harmful weather.

Electrically ground this product.

Failure to follow these instructions can result in 

fire, electrical shock, or death.

Electrical Shock Hazard

Electrical Shock Hazard

Plumbing

To facilitate future technical 

assistance and/or parts orders, 

please copy the details from the 

compressor nameplate onto this 

page and save for future reference.

Back to Contents

Содержание KM-120

Страница 1: ...00 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 771068 Document version 2021 1 0 KM SERIES COMPRESSOR Teich Aire ...

Страница 2: ... TABLE OF CONTENTS 715 262 4488 kascomarine com sales kascomarine com QUESTIONS Product Overview 2 Installation 3 Electrical 4 Operation 5 Maintenance 6 Troubleshooting 7 Warranty 8 Other Repairs 9 Repair Contact Form 10 ...

Страница 3: ...armful elements of the outdoor environment Ambient air temperature readings taken 4 away from any surface of the compressor must not exceed 104 F 40 C Ensure that adequate ventilation and cooling air flowing across the compressor is available to keep the compressor from overheating which can cause premature damage Mount the compressor to a stable rigid operating surface Using the provided shock mo...

Страница 4: ... air filter in one inlet port Kasco recommends installing a pressure relief valve in an outlet port to bleed off excess pressure in case of a blocked line Check valves may be required to prevent back flow through the compressor KM 60 KM 60HC EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter connected to...

Страница 5: ... condition or is inadequate for the requirements of this product Failure to follow these instructions can result in fire electrical shock or death Make sure that the power supply voltage agrees with that listed on the product nameplate All cords with plugs must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Hardwired installation...

Страница 6: ... tor may exceed 70 dBA Failure to follow these instructions can result in burns eye injury or other serious injury Injury Hazard OPERATION It is your responsibility to operate this compressor at recommended pressures and permissible ambient temperatures Do not start against a vacuum or pressure load If the motor fails to start or slows down significantly under load shut off and disconnect from the...

Страница 7: ...electrical power supply to unit Vent all air lines Remove filter cover Remove and replace filter element as necessary Replacement filter elements are readily available Please contact your local Kasco distributor and ask for the replacement air filter element part 771014 for KM 60 or KM 120 Models or part 771018 for KM 200 Models Reinstall filter element and cover MAINTENANCE WARNING Allow product ...

Страница 8: ...lve is set too high Inspect and adjust Relief valve is set too low Inspect and adjust Plugged pressure line Inspect and repair Low voltage will not start Check power supply Incorrect voltage Check power supply Worn cup piston hitting cylinder Replace Cylinder misadjustment Realign Leaky hose or check valve Replace Dirt or liquid on top of piston Inspect and clean Motor not wired correctly Check wi...

Страница 9: ...it may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information and or Repair Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local distributor with the shipment If no repair ...

Страница 10: ...amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore the unit as closely as possible to the condition in which we found it and ship at the customer s expense including shipping and handlin...

Страница 11: ...a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the c...

Отзывы: