CABLE SUPPORT

1. 

Attach the cable support (Q) to the connecting link (N).

2.  Close and tighten the connecting link.

3. 

Feed power cable through the cable support (Q).

Fig. 17

4. 

Continue to feed power cable through the cord grip (O) and out of the tank 

until all excess cord length has been taken up, leaving only enough so that 

there is no strain on the cable. 

5. 

Tighten the top nut on the cord grip (O) to seal the power cable penetration. 

6. 

Terminate the power cable into an exterior junction box (not supplied by 

Kasco). 

Fig. 16

Q

N

Fig. 18

O

Back to Contents

Содержание CertiSafe

Страница 1: ...CertiSafe Suspended Mount Assembly Installation Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 852112 ...

Страница 2: ...Included 5 Tank Penetration for Cable Support and Cord Grip 7 Stretcher Assembly 9 Suspension Chains and Power Cable 10 Cable Support 11 CertiSafe Tank Mixer Maintenance Recommendations 12 CertiSafe Tank Mixer Warranty 13 Non Warranty Repairs 14 Repair Contact Form 15 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com Questions ...

Страница 3: ...afe installation of a CertiSafe Tank Mixer These may include but are not limited to OSHA CCOHS and other regulations related to Working over or near water Fall protection systems Falling object protection systems Electrical standards Illumination Ventilation Installation of CertiSafe Tank Mixers requires entry into environments that pose potential hazards such as those described in section 1910 14...

Страница 4: ...suitable for contact with potable water and certified to meet the shrinkage for interior and exterior use Refer to NSF ANSI Standard 61 for indirect additives Be aware of clearance between the mixer assembly and any fixed objects within the tank including ladders ensuring that there is enough room for the CertiSafe unit to function correctly and avoid damage to any protective coatings Please consu...

Страница 5: ...r 4 566208 G Long chain 50 ft 2 636382 H Short chain 2 636383 I Zip ties 12 415038 Tank Penetration J 5 16 eye bolt 2 566226 K 5 16 nylon locknut 2 566202 L 5 16 flat washer 4 566204 M 5 16 sealing washer 2 566229 N Connecting link 2 636342 for use with Cord AWG Ships with CertiSafe mixer O Cord grip 14 16 AWG 1 997210 12 AWG 997211 10 AWG 997212 P Cord grip nut 12 16 AWG 1 997215 10 AWG 997216 Q ...

Страница 6: ...locknut K 5 16 sealing washer M Connecting link N Cord grip O Cord grip nut P Cable support Q 1 4 20 x 1 2 shoulder screw C 1 4 20 nylon locknut E CertiSafe jaw slide B Steel tank roof 5 16 flat washer L 5 16 flat washer L Fig 1 1 4 20 x 1 2 shoulder screw C 1 4 20 x 3 4 shoulder screw D 1 4 flat washers F 1 4 20 nylon locknuts E Steel tank roof Back to Contents ...

Страница 7: ...lts J 2 Deburr both sides of each hole 3 Drill a 7 8 clearance hole approximately 4 from one of the holes drilled in step 1 This is for the cord grip O 4 Deburr both sides of the third hole 5 From the tank exterior pass the O ringed side of the cord grip O through the 7 8 hole with the O ring outside the tank roof 6 From the tank interior fit the cord grip nut P on the threads protruding into the ...

Страница 8: ... 8 hole 10 From the tank exterior fit a second flat washer L onto the eye bolt 11 Fasten the 5 16 nylon locknut K to the eye bolt 12 Tighten the locknut until snug being careful not to damage the sealing washer 13 Attach the top connecting link N to the eye bolt L M L K N Steel tank roof Steel tank roof J L M Fig 5 Fig 6 Fig 7 Repeat steps 8 through 13 for the second eye bolt pass through Back to ...

Страница 9: ... for the other cage loop and short chain H 4 Tighten all locknuts until snug without over tightening 5 Insert one short chain loop H into an inner jaw slide B affixed to the stretcher bar A 6 Secure with 1 4 20 x 1 2 shoulder screw C and locknut E 7 Repeat steps 5 and 6 for the second inner jaw slide B fastening the chain H with another shoulder screw C and locknut E 8 Tighten all locknuts until s...

Страница 10: ...r tighten 5 Use zip ties I to secure the power cord to the stretcher bar A in two places and to guide the cord around the corner where the bar meets the long chain making sure not to put tension on the power cable 6 Continue to apply the zip ties I every 4 feet along the long chain G and power cable length 7 Attach the long chain G with the power cord to the connecting link N closest to the cord g...

Страница 11: ... cable support Q Fig 17 4 Continue to feed power cable through the cord grip O and out of the tank until all excess cord length has been taken up leaving only enough so that there is no strain on the cable 5 Tighten the top nut on the cord grip O to seal the power cable penetration 6 Terminate the power cable into an exterior junction box not supplied by Kasco Fig 16 Q N Fig 18 O Back to Contents ...

Страница 12: ...t can alert you to problems with the mixer It is important to test the GFCI upon installation after each re installation and regularly thereafter to ensure consistent operation If you experience repeat interruptions disconnect and remove the equipment Inspect the power cord and unit mixer for damage If no damage is apparent please contact your Kasco distributor or representative for further instru...

Страница 13: ...h the motor assembly unless specifically requested by a Kasco representative Please attach a repair form with the shipment The repair form must include a name physical address for return delivery of the repaired unit daytime phone number and an e mail address for correspondence regarding the warranty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco ...

Страница 14: ...w a stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the customer specifies otherwise If the customer would like the product returned Kasco will return the unit to the condition in which we received it and we will ship it at the customer s expense Billing ...

Страница 15: ...nstructed A fee of 60 per hour will be assessed for cleaning excessively dirty units Refer to the CertiSafe Tank Mixer Operation Maintenance Manual for easy to follow troubleshooting tips to rule out site issues Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Street City State ZIP code Phone n...

Отзывы: