and cycle the De-icer on temperature.

•  To bypass the thermostat and operate only on 

time, set the thermostat to its highest temperature 

setting. Use the timer settings to cycle the de-icer.  

Note: If the ambient temperature rises above the 

thermostat highest setting, it will shut off the  

de-icer.

•  When not in use (summer time), store the C-20 

indoors away from salt air. This will help extend 

the life of the C-20 controller.

•  Operate with the door closed to keep salt air away 

from internal components.

•  Mount the C-20 out of direct sun light. This will 

prevent excessive internal heating of the controller.  

Internal heating may prevent the C-20 from 

operating correctly.

WARRANTY:

Kasco Marine, Inc. warrants the C-20 to be free from 

defects in material or workmanship under normal use 

and service. The Kasco Marine, Inc. obligation under 

this warranty is limited to replacing free of charge 

any defective part within two (2) years from date of 

purchase. Customer shall pay all shipping charges.

THIS WARRANTY IS IN LIEU OF ANY OTHER 

WARRANTIES EXPRESSED OR IMPLIED, AND 

ANY OTHER OBLIGATION OR LIABILITY 

WHATEVER ON THE PART OF KASCO MARINE, 

INC. AND IN NO EVENT SHALL KASCO 

MARINE, INC. BE LIABLE FOR ANY SPECIAL 

OR CONSEQUENTIAL DAMAGES.

No warranty registration is required, only original 

purchase receipt is needed for limited warranty 

coverage.  Warranty is void: If the C-20 is damaged by 

unauthorized tampering or modifications.

The Industry Leader in 

Ice Control Engineering.

Kasco Marine, Inc.

800 Deere Rd.

Prescott, WI 54021

PH (715) 262-4488  

FAX (715) 262-4487

www.kascomarine.com

www.de-icer.com

brackish water will freeze somewhere in between. 

Setting the thermostat a couple degrees below the 

freezing point can minimize unneeded operation 

time.

•  Daily observation is required for all de-icing 

installations. Adjust operating times based on 

when you can observe the operation. This will help 

you check the de-icer is operating properly.

•  Several factors can increase freeze rate. Such 

as, wind, snow, and colder temperatures. When 

picking operation times, set the de-icer to operate 

more when conditions promote quicker freezing.

• 

Your settings will likely require some fine tuning. 

Remember to observe your de-icer installation 

and be prepared to adjust your settings of the 

C-20.  Thermostat tolerance may also need to 

be adjusted for. The actual ON/OFF point of the 

thermostat may be -/+ 2.7°F of the actual ambient 

temperature.  

•  Operating with fewer, longer cycles will provide 

the most efficient de-icing. The following is an 

example of setting the timer over a 24 hour period.  

The 4 ON cycles below allow for more operating 

time during dark hours and less during daytime 

hours. (This is suggested due to increased freezing 

rate at night).

Cycle Time

Length

ON

7:00 a.m. - 9:00 a.m.

2 hr

OFF

9:00 a.m. - 1:00 p.m.

4 hr

ON

1:00 p.m. - 3:00 p.m.

2 hr

OFF

3:00 p.m. - 7:00 p.m.

4 hr

ON

7:00 p.m. - 10:00 p.m. 3 hr

OFF

10:00 p.m. - 12:00 a.m. 2 hr

ON

12:00 a.m. - 5:00 a.m. 5 hr

OFF

5:00 a.m. - 7:00 a.m.

2 hr

This sample would allow the de-icer to operate a 

maximum of 12 hours in a 24 hour period. During 

the ON cycles, the thermostat would determine if 

the de-icer operates based on its dial setting. Actual 

settings and durations of run time will depend on your 

installation requirements and regional demands for 

de-icing.

•  To bypass the timer and operate only on 

temperature, set the timer ON/AUTO switch to 

ON. This will turn the timer output on indefinitely 

 #824401   Rev. 02/12/15

Отзывы: