TROUBLESHOOTING TIPS

More troubleshooting tips can be found at 

www.kascomarine.com

.

“My circulator trips the ground fault protection device.”

To correctly diagnose the problem, you will need to collect more information. A breaker that trips can indicate 

an electrical service problem, water contamination in the unit and/or cord, bad breaker, control box problems, 

motor problems, etc. Try to find out the answers to these questions before you consult an electrician. 

• 

How long does it take to trip the breaker? 

• 

Does it always take the same amount of time to trip? 

• 

How many times has it tripped? 

• 

Have there been any recent electrical problems in the area?

“My circulator seems to run slowly.”

There unit might not be receiving the proper voltage. This could also indicate a problem with the motor of the 

unit, which needs to be examined by an Authorized Repair Center. Check that the unit is receiving the proper 

voltage, and, if so, contact Kasco for further steps.

“My circulator hums, but will not start. When I spin the prop with a stick, it starts up.”

Each Kasco AquatiClear is equipped with a starting capacitor to get the unit going when it is first plugged in. If it 

is operating, but not spinning and can be started by spinning the prop with a stick, the starting capacitor needs 

to be replaced by an Authorized Repair Center.

“My circulator turns itself off and back on without the timer and without tripping the GFCI breaker.”

Each Kasco unit has a thermal overload built in that will turn the unit off when it overheats. Once the unit has 

cooled down, it will start back up. If you are noticing these symptoms, the unit should be unplugged immediately 

because the thermal overload will continue to turn on and off until it burns out and damages the motor. The 

unit should be unplugged and taken out of the water to find the cause of the problem. The problem could be 

low water levels, build-up on the unit preventing heat dissipation, something inhibiting the free rotation of the 

shaft, etc. If something is caught in the unit or there is a build-up on the unit, remove the debris. Contact a Kasco 

representative before restarting the unit.

“My circulator flow seems to fluctuate and/or be less than usual.”

Most of the time, this symptom is caused from unit being clogged with debris. A mat of weeds, leaves, plastic 

bags, etc. can clog up the unit and cause it to be starved of water. If the unit does not have the proper amount 

of water, the flow or pattern will fluctuate up and down and look uneven. If you are seeing these symptoms, first 

try turning off the unit and/or unplugging it for 10 seconds, allowing debris to fall away. If the problem persists, 

unplug the unit and clean away any debris that is clogging the guard. While the unit is unplugged, also check for 

a chipped or damaged prop that could be causing the unit to wobble and replace the prop if damage is found.

“The breaker trips randomly and sporadically. Sometimes it is a few hours of operation, other times it can be days 

or weeks.”

This is referred to as a nuisance trip. This usually occurs where the unit is installed far away from the initial 

electric service on the property where the ground stake is placed. It is caused by either induced current in the 

ground wire or a base voltage difference due to soil pH levels. Contact an electrician to install a local grounding 

stake; this may eliminate the induced current and any base voltage differences.

Содержание AquatiClear 2400EC

Страница 1: ...ott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 CIRCULATOR Operation Maintenance Manual Document 884149 Version 2021 1 0 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 AquatiClear 50 Hz ...

Страница 2: ...cal and or moving equipment NEVER run the unit out of water NEVER lift or drag the equipment by the power cord Follow all boating safety rules and regulations during installation Single phase units are supplied with an internal grounding conductor and a grounding type attachment plug To reduce the risk of electrical shock be certain that the unit is plugged into a protected circuit Control panels ...

Страница 3: ...arine backs each AquatiClear unit with a 2 Year Warranty This warranty covers any and all manufacturer s defects within the warranty period from the date of purchase Use and Operation Kasco Circulators are designed and engineered for continuous duty Upon installation your Kasco AquatiClear is ready for immediate use Make sure to keep the motor housing clean from hard water deposits and or algae Mo...

Страница 4: ... 243410 B 1 2 washer 1 475642 C Propeller 2400EC 1 340135 C Propeller 3400EC 1 440435 D AquatiClear prop guard 1 993210 E 1 4 20 x 1 1 2 screw 3 475695 F Retaining clip 3 140312 G 1 4 20 nut 3 840538 H Sealed motor unit 1 N A I Prop stop 1 440630 J Sacrificial anode 1 243474 F A B D C E G H I J ...

Страница 5: ...The upper mount can be secured horizontally as shown above or vertically right allowing installation options for a variety of shoreline structures Easily lower angle and position units for proper water movement Mount to a dock piling wall or other in water property Packages include upper and lower mount assemblies pipe supplied by customer Float Mount Kasco s Horizontal Float suspends the unit in ...

Страница 6: ...n and above freezing temperatures During the offseason store the unit on its side to help prevent the seals from drying out Cleaning Remove circulators from the water at least once per year to clean the exterior of the system especially the stainless steel motor housing can to avoid build up of algae calcium or other materials This buildup can lead to overheating In warmer regions Kasco recommends...

Страница 7: ...hese symptoms the unit should be unplugged immediately because the thermal overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the cause of the problem The problem could be low water levels build up on the unit preventing heat dissipation something inhibiting the free rotation of the shaft etc If somethi...

Страница 8: ...AQUATICLEAR CIRCULATOR MANUAL 8 SACRIFICIAL ANODE REPLACEMENT A B C 1 2 E F G 3 6 4 5 x 3 Tighten this nut first and proceed counterclockwise 7 ...

Страница 9: ...CI control box The equipment is damaged by unauthorized tampering The sacrificial anode around the propeller shaft shows significant deterioration The anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Warranty period is established by the original receipt For efficient service please register the unit online www kascomarine com Once warranty coverage has been ...

Страница 10: ... Customer pre approves repair of the unit if costs are below a stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the customer specifies otherwise If the customer would like the product returned Kasco will return the unit to the condition in which we receive...

Страница 11: ...hemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the cust...

Отзывы: