manualshive.com logo in svg
background image

11

Control Panel Installation

STEP ONE

Inspect the panel for any damage and any components 

that may have loosened during shipping.

Control panel must be installed a minimum of 5ft (3m 

in Canada) from the inside wall of the pond, unless 

separated from the body of water by a fence wall, 

or other permanent barrier that will make the unit 

inaccessible to persons in the water.

Install the control panel to a post structure, side of a 

building, or other reliable means.  This structure must 

support the panel and prevent movement/flexing of the 

panel.  Use #10 x 1” or longer screws in the mounting 

points of the control panel to secure to the post 

structure.  NOTE:  The control panel must be hung 

upright in order to be waterproof.  It is also advised 

to mount the panel out of direct sunlight if possible.  

Mounting the panel in a North direction will prevent 

heat buildup inside the panel.  Also, mount the panel 

above the potential flood plain to prevent water entry 

during a possible flood event.

STEP TWO

Set Timer in the control panel to desired ON and OFF 

times per the Instructions for each specific timer.  

STEP THREE 

Follow all local and national electrical codes for 

this installation and Consult a qualified electrician 

or service person if needed.

(For 120V Installations)

Plug the aerator cord into the C-25 outlet labeled 

“UNIT”.  If lights are included, plug the Transformer 

cord into the C-25 outlet labeled “LIGHT”.  Now you 

are ready to plug the C-25 into the 120V power supply 

on the post and ENJOY YOUR NEW KASCO AERA-

TOR!

STEP THREE (For 240V Installation)

All electrical connections to this panel must be made 

with proper strain relief cord grip fittings or with 

conduit connections as required by local and national 

electric codes.  The bottom of the enclosure is reserved 

for field installation of these connections.

Installation Instructions

Use the ropes to position the Fountain in the desired 

location in the pond/lake.  Anchor the ropes or secure 

them to the shoreline so the ropes are free of slack, but 

not tight.  To prevent twisting of the unit due to torque, 

you should place the anchor at least 3 feet from the 

float for each foot of depth (Ex. A 6 foot deep pond 

would require an anchor 18 feet horizontally from the 

float.)  

ALTERNATE INSTALLATION

In ponds where the water level fluctuates significantly, 

you may need to suspend a small weight (12” of 1” 

galvanize pipe works well) at the mid-point of the 

rope to take up any slack as the water level drops.  The 

weight should be light enough so the Fountain can rise 

as the water level rises.  This can also help hide ropes 

by sinking them further below the surface.

Содержание 3400HJF

Страница 1: ...ol Panel Installation pg11 C 25 Timer Control Instructions pg13 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic Control Panel Timer pg15 Maintenance Recommendations pg16 Warranty Policy pg17 Troubleshooting Tips pg18 3400J Replacement Parts pg20 4400J Replacement Parts pg21 Customer Repair Form pg22 Registration Information pg24 Rev 06 17 16 Kasco Marine Inc 800 Deere Rd Prescott WI 5402...

Страница 2: ... not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied with an internal ground ing conductor and a grounding type attachment plug To reduce the risk of electrical shock be certain that the fountain is plugged into the C 25 Control Box 120V or C 85 Contro...

Страница 3: ...eady for immediate use after installation The motor and ball bearings are submerged in oil and no further lubrication is needed Make sure to keep the motor housing clean from hard water deposits and or algae See Mainte nance Recommendations It is extremely important that proper and sufficient voltage 120V or 240 208V is supplied to the Foun tain motor Each 120V Fountain is supplied with a UL and C...

Страница 4: ...er screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners 3400JF 3400HJF Parts Included Item Part Qty 1 3400JF Aerator 1 2 Float 242001 1 3 1 4 20 x 3 1 2 Phillips Pan Head Screw 251210 4 4 1 4 split washers 840537 7 5 1 4 3 4 OD Flat Washer 251300 10 6 1 4 20 x 1 3 4 Hex Head Bolt 475630 3 7 Bottom Screen Section 361540 3 8 1 4 20 Nut 840536 3 9...

Страница 5: ...n bolt holes with legs 2 Lock washer goes between bolt and flat washer Tighten down in 4 places 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembly Use cable tie instead 5 Secure the bottom screen to the float in 3 places Make sure cord is sticking out of notch ...

Страница 6: ...cone of the pump 7 Thread one rope through one weighted tube rope Weight and position it approximately 6 from the float Next thread the end of the rope back through the opening facing the float as shown Repeat with the second rope and weight 8 If ready to install in the pond go to Installation instructions Light Kits can also be installed at this time go to Light kit instructions ...

Страница 7: ...pond on a post with room for mounting the C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners 4400JF 4400HJF Parts Included Item Part Qty 1 4400JF Aerator 1 2 Float 242001 1 3 1 4 20 x 4 PhilPan Head Screw 251220 4 4 1 4 split ...

Страница 8: ...n bolt and flat washer Tighten down in 4 places to the float retaining clips 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembly Use cable tie instead 5 Secure the bottom screen to the float in 3 places Make sure cord is sticking out of notch Secure to top ring of cage ...

Страница 9: ...f Without Strain Relief 6 Choose Nozzle Fit bolt into the molded socket on the nozzle and thread into the inner cone of the pump 7 If ready to install in the pond go to Installation instructions Light Kits can also be installed at this time go to Light kit instructions ...

Страница 10: ... by regional electrical differenc es or voltage drop due to long power cords may result in reduced pattern sizes The Cypress is the only nozzle that uses the sepa rate collar labeled C2 The Cypress Linden Willow and Juniper nozzles use the 3 8 x 4 bolt The Sequoia nozzle uses the shorter 3 8 x 2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the f...

Страница 11: ...ectrician or service person if needed For 120V Installations Plug the aerator cord into the C 25 outlet labeled UNIT If lights are included plug the Transformer cord into the C 25 outlet labeled LIGHT Now you are ready to plug the C 25 into the 120V power supply on the post and ENJOY YOUR NEW KASCO AERA TOR STEP THREE For 240V Installation All electrical connections to this panel must be made with...

Страница 12: ... provided with this panel L1 connects to Terminal 1 L2 connects to Terminal 2 N connects to Terminal N G connects to Terminal GROUND located on hassis plate Be sure to provide adequate sized power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump will be provid...

Страница 13: ...n 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRES SURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RE SET PROPERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHN...

Страница 14: ...14 C85 non metallic Wiring Diagram ...

Страница 15: ...ur and the minute dial will show exac ly 10 30 PROGRAMMING Dimensions FM 1 synchronous quartz TIME SETTING TO SET THE CURRENT TIME AND DAY OF WEEK ON 7 DAY UNITS TURN THE MINUTE HAND CLOCKWISE DO NOT SET THE TIME BY ROTAT ING OUTER DIAL Turn the minute hand clockwise until the day of the week 7 day timer and the time of day on the outer dial is aligned with the triangle marker on the inner dial tw...

Страница 16: ...all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or changes made to Kasco units by an unauthorized source will Maintenance Recommendations Under No Circumstances should anyone enter the water while a fountain is operating Please keep the original box fo...

Страница 17: ...ur local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void the warranty This includes tampering with the unit power cord and or control box Please contact Kasco Marine Inc at 715 262 4488 for your nearest Authorized Repair Center Warranty Policy Warranty Perio...

Страница 18: ... off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If dress for correspondence regarding the warranty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will return units repa...

Страница 19: ...ved of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the debris that is clogging up the screen Another possibility if these symptoms are noticed is a chipped or damaged prop that is causing the unit to wobble and not pump properly When the unit is unplugge...

Страница 20: ...25 MAIN HOUSING 2400J 3400J 1 7 241005 V TUBE WITH LEGS 1 8 342050 IMPELLER 3400J 1 9 990275 O RING CORD 1 10 475643 SHAFT WASHER 2 11 243475 ZINC ASSEMBLY 1 12 990280 SEALING PLUG 1 13 990281 O RING 1 14 990410 DEBRIS FLINGER 500 DIA SHAFT 1 15 990600 TOP ASSEMBLY 2400 3400 1 16 390100 CAN 3400 4400 SERIES 1 17 140312 RETAINING CLIP 4 18 840537 LOCK WASHER 1 4 4 19 251250 14 X 1 1 4 LONG HEX WASH...

Страница 21: ...21 4400J Replacement Parts ...

Страница 22: ... panel with unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule out site issue Note Contact Information Should be that of the person or company to contact for repair Company First Name Last Name Address City State Zip code Phone Alternate Phone Email Add...

Страница 23: ...23 ...

Страница 24: ..._______ Serial Ex 5101J341725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884180 ...

Отзывы: