3
Parts Included
8400JF, 3.1JF, or 5.1JF Aerator
2.3JF, 3.3JF, or 5.3JF Aerator
(Unit with cord or unit with Disconnect) (1)
A1. Cord in separate box (1) (depending on size of cord)
B. Float in separate box (1) (Diagram)
#
Item
Part #
Qty
1a
Float Sections (2, 3 HP only)
284001
3
1b
Float Sections (5, 7.5 HP only)
251001
3
2
Top Float Bracket
840157
3
3
Bottom Float Bracket w/Rope
840158
3
4
9.5” x 3/8” Bolt
840159
6
5
3/8” Lock Nut
462214
6
6
Bottom Screen
990162
1
7
Top Screen
840175
1
8
Top Screen Clip
223111
3
9
1/4-20 x 3/4” brass screw
664750
3
10
1/4” Lock Washer
840537
3
11
1/4” Nut
840536
3
12
Bottom Screen Clip
223240
3
13
3/8” x 1” Bolt
566250
3
14
3/8” lock washer
566230
3
15
Mesh screen
990170
1
16
Cable ties for mesh
415038
10
8400JF, 3.1JF, 2.3JF, 3.3JF parts diagram
5.1JF, 5.3JF, 7.3JF parts diagram
Your Kasco Marine aerator is ready for immediate use
(after installation). Make sure to keep the motor hous-
ing clean from hard water deposits and/or algae. (See
Maintenance Recommendations)
It is extremely important that proper and sufficient
voltage is supplied to the aerator motor. Unit should
be protected by a GFCI. Control panels must be
installed by a qualified electrician. (See Installation
instructions).
Kasco aerators are lightweight, energy efficient, and
easy to install and operate. We strive to produce prod-
ucts that exceed customer expectations. We hope you
enjoy your Kasco aerator.
UNIT STORAGE
When storing units during the offseason, it is impor-
tant to store them upside down if they are going to be
sitting for long periods of time. Units that sit upright
on a shelf for many months, or even years have a
greater likelihood of seals drying out. Storing upside
down will ensure oil is lubricating the seals and pre-
vent drying.
Unit Specs
Single Phase
208-240 Volt
8400JF
3.1JF
5.1JF
Voltage
208-240
208-240
208-240
Amps
10.5
13.4
20
Lock rotor
amps
40
61
97
Control box
connection
C-85
Hardwire at
shore
C-95
Hardwire at
shore
C-95
Hardwire at
shore
Aerator
connection
plug or
hardwire
into C-85
plug or
hardwire
into C-85
hardwire
into C-95
3 phase 208-
230 Volt
2.3JF
3.3JF
5.3JF
7.3JF
Voltage
208
208
208
208
Amps @208V
7.5
10.3
16.0
20.0
Lock rotor
amps
40
70
100
100
3 phase 460
Volt
2.3HJF
3.3HJF
5.3HJF
7.3HJF
Voltage
460
460
460
460
Amps
3.6
5.1
7.8
10.0
Lock rotor
amps
24
40
49
50