1/2HP-1HP AERATOR & CIRCULATOR MANUAL
11
9. Tie mooring ropes to both chains and to the tie-down ring to provide three anchor points for the unit
and float (A) as shown below.
10.
Attach the chain from the cord strain relief assembly to the tie-down ring on the float.
11. Continue to circulator installation instructions on page 12.
6.
Secure the tie-down ring (D) to the float using another 1/4”-20 x 1/2” serrated flange screw (E).
7. Attach snap clips (L) to both ends of both chains (K).
8. Use the snap clips to attach the chains to the cage as shown below, evenly spaced on either side of the
cage clamp.
Cage clamp
ASSEMBLY INSTRUCTIONS (CIRCULATOR, CONT.)
E
D
K
L
L
6
7
8
9
A
10
If your cord does not have a strain relief
clamp and chain attached, you can use a
spare cable tie to secure the cord to the tie-
down ring on the horizontal float.
Back to Contents