MAINTENANCE RECOMMENDATIONS
** Under No Circumstances should anyone enter the water while a fountain is operating. **
** Please keep the original box for maintenance shipping. **
The following maintenance procedures can be utilized to ensure many years of quality performance from your
Kasco Fountain and reduce the need for more costly repair work.
•
PROPER INSTALLATION:
Proper installation of Kasco equipment will include a power source with
ground fault interruption. For Fountain models, the C-25 control (120V) included with the unit has built-in
ground fault interruption that is sufficient. Ground fault interrupters are a safety feature that can also alert
you to electrical leaks in the equipment. If you have repeat, consistent trips on your ground fault, the
equipment should be disconnected and removed from the water. The power cord should be inspected for
damage and you should call Kasco Marine at 715-262-4488 for further instructions or email Kasco at
[email protected].
•
OBSERVATION:
Operating equipment should be observed on a regular basis (daily, if possible) for any
reduction or variation in performance. If a change in performance is observed, the equipment should be
disconnected from power and inspected for any material that may have clogged the system or wrapped
around the shaft of the motor, especially plastic bags and fishing line. Even though Kasco Aerators and
Fountains are among the most clog-resistant on the market, it is impossible to protect against all items that
can clog equipment and still maintain a flow of water. These materials can be very damaging to the equip-
ment under continued operation and must be removed as soon as possible. ALWAYS UNPLUG THE
UNIT BEFORE ATTEMPTING TO REMOVE CLOGS.
•
WINTER STORAGE:
In regions where there is significant freezing in the wintertime, the fountains
should be removed from the water to protect them from the expansion pressure of the ice. In many areas,
fountains will keep some amount of ice open through the winter. However, when the water is thrust into
the air, it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond/
lake. Storage over winter is best in a location that is out of the sun and cool, but above 32
O
F. It is not nec-
essary to store Kasco motors upside down. All internal seals are fully lubricated while stored in an upright
position.
•
CLEANING:
Fountains should be removed from the water at least once per year (at the end of the season
in cold climates) to clean the exterior of the system, especially the stainless steel motor housing (can). The
motor housing is the surface that dissipates heat into the water and any algae, calcium, etc. build-up will
become an insulator that blocks heat transfer. In warmer regions it is recommended that the motor is re-
moved and cleaned at least two to three times per year depending on conditions. In most cases a power
washer will be sufficient if the unit and algae are still wet.
•
SEAL AND OIL REPLACEMENT:
This is a sealed motor assembly and seals will wear out over time
(similar to break pads on a car). Replacement of the seals and a change of oil after three to five years may
add longevity to the operation of the motor, saving you the cost of more expensive repairs. In warmer cli-
mates where the fountain runs most or all of the year, it is a good idea to replace seals more regularly than
you would need to in colder climates where the unit is removed from the water for several months.
Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Au-
thorized Repair Center. Any alterations or changes made to Kasco units by an unauthorized source will void
the warranty. This includes tampering with the unit, power cord, and/or control box. Please contact Kasco
Marine, Inc. at 715-262-4488 for your nearest Authorized Repair Center.
6