Kasco marine 1400JF Скачать руководство пользователя страница 1

 

 

Kasco Marine, Inc. 

800 Deere Rd. 

Prescott, WI 54021 

Phone (715) 262-4488  *  Fax (715) 262-4487 

www.KascoMarine.com  *  [email protected] 

CONTENTS

 

I. Safety 

Instructions 

……………………………………               2 

II.   General Owner’s Instructions………………………...               3 
III.  Warranty, Warranty Claim, & Return Policy…………  

 4-5 

IV.  Maintenance Recommendations……………………..               6 
V.   C-25 Instructions……………………………………… 

    7 

VI.  Parts Included & Tools Needed………………………              8 
VII.  Nozzle Options & Pattern Sizes……………………..              9 
VIII. Replacement Parts & Assembly Diagram……………           10 
IX.   Assembly & Installation Instructions…………………      11-12 
X.  Troubleshooting Tips…………………………………..           13 
XI.  Warranty Registration Information……………………           14  

Patent Pending 

Made in the USA 

Содержание 1400JF

Страница 1: ...ner s Instructions 3 III Warranty Warranty Claim Return Policy 4 5 IV Maintenance Recommendations 6 V C 25 Instructions 7 VI Parts Included Tools Needed 8 VII Nozzle Options Pattern Sizes 9 VIII Replacement Parts Assembly Diagram 10 IX Assembly Installation Instructions 11 12 X Troubleshooting Tips 13 XI Warranty Registration Information 14 Patent Pending Made in the USA ...

Страница 2: ...with the electrical equipment plugged in and or in operation All Kasco equipment is ETL approved to UL and CSA stan dards for safety in water and all fountain models included control panels with GFI protec tion However it is NEVER recommended to enter the water with the equipment in opera tion Caution should be used when dealing with any electrical and or moving equipment NEVER run the unit out of...

Страница 3: ...om the date of purchase See Warranty Warranty Claim Return Policy on pages 4 5 Please fill out the enclosed ad dressed Warranty Card and mail it to Kasco Marine to start your warranty coverage You may also register your Fountain online at www kascomarine com solutions_warranty_registration htm USE AND OPERATION Kasco Fountains are designed and engineered for continuous duty such as on fish farms o...

Страница 4: ...ment Cuts in the power cord are not covered under warranty The Fountain is damaged by unauthorized tampering Warranty Claim Procedure Check the eight digit serial number printed either on the black cover of the motor or on the blue nameplate and determine the year of manufacture according to the serial number scheme below Sample Serial 50 J 1 1725 The first two digits represent the reverse of the ...

Страница 5: ...eight within the continental United States Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship ac cording to the instructions in the previous section Again it is best to call ahead for a Return Authorization Number and or Repair Form so we know the repair is coming Kasco Marine offers free estimates on repairs at the request of the...

Страница 6: ...should be removed from the water to protect them from the expansion pressure of the ice In many areas fountains will keep some amount of ice open through the winter However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32...

Страница 7: ...T TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROP ERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNICIAN Failure to use the C 25 with Kasco Fountains will void the warranty and cause the Foun...

Страница 8: ...ds and a mooring rope 1 TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 2 B Flat Head Screw Driver C Philips head screw driver for mounting C 25 and Transformer if lights are included and installing nozzles D 120V Electrical Supply near pond on a post with room for mounting the C 25 and Transformer if lights are included E Two 12 pieces of 1 galvanized pipe for weighting ropes option...

Страница 9: ...omes installed on unit Condor Produces a two tiered arch of water with an inner arch 4 feet high by 4 feet in diameter and an outer arch 2 feet high by 10 feet in diameter To use this nozzle you must have the upper pump housing in place This nozzle has flared outer fins and has the number 2 molded on the top of the nozzle Hawk s Nest Produces a narrow V pattern of water 3 feet high by 7 feet in di...

Страница 10: ...7 LOCK WASHER 1 4 3 12 146400 6 X 3 4 LONG FILLISTER HEAD SS 4 13 144100 SCREW SELF TAPPING 1 14 142212 NOZZLE 1400 SERIES 1 23 140925 PROP 1400 1 24 443154 1 4 20 x 3 8 FILLISTER 1 25 181625 TRANSFORMER 60 WATT 1 26 142312 NOZZLE 1400 SERIES FALCON 1 27 142412 NOZZLE 1400 SERIES CONDOR 1 28 142012 NOZZLE 1400 SERIES HAWKS NEST 1 29 142112 NOZZLE 1400 SERIES EAGLES NEST 1 30 475628 1 4 20 X 7 8 FI...

Страница 11: ... Phillips Head Screw and tighten until snug Diagram A If either the Eagle s Nest or Hawk s Nest patterns are desired you must remove both the Osprey Nozzle and the Upper Pump Housing Re move the Osprey nozzle first as above Second remove the 4 Upper Pump Housing screws and pull the Upper Pump Housing up Finally re move the 3 8 Fillister head plastic set screw in the top of the 4 Blade Prop Place a...

Страница 12: ...e water level drops The weight should be light enough so the Fountain can rise as the water level rises This can also help hide ropes by sinking them further below the surface STEP EIGHT Install the C 25 on the post with the power supply Use up to three 10 x 1 long or longer screws and the molded screw placements on the C 25 NOTE The C 25 must be hung upright in order to be water proof Install the...

Страница 13: ...you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the cause of the problem The problem could be one of many such as low water levels build up on the unit to prevent heat dissipation something inhibiting the fre...

Страница 14: ...gister your fountain online at www kascomarine com solutions_warranty_registration htm Also fill in the information below and keep for your records Model Ex 1400JF _______________________________ Serial Ex 50J11725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ How Registered Mailed Card or Registered Online Registration Date D...