Kartsana TG-241 Series Скачать руководство пользователя страница 7

                                                

OPERATION AND HANDLING OF THE  

TG-241 SERIES

 

Rev.2 
23-10-15 

-  Failure  to  properly  clean  or  dispose  of  contaminated  mattress  or  other  stretcher  components  will  increase  the  risk  of  bloodborne 
pathogens and may cause injury to the patient or operator. 

 

CAUTIONS: 

Changes or modifications to the unit not expressly approved by Kartsana could void the user’s authority to operate the system. 

-  Installation of the safety hook should be done by a certified mechanic  familiar with ambulance vehicle construction. Consult the vehicle 
manufacturer  before  installing  the  safety  hook  and  be  sure  that  the  installation  of  the  safety  hook  does  not  damage or interfere with the 
brake lines, oxygen lines, fuel lines, fuel tank or electrical wiring of the vehicle. 

- Before operating the stretcher, clear any obstacles that may interfere and cause injury to the operator or patient. 

- When unloading the stretcher from the patient compartment, ensure that the caster wheels are safely set on the ground or damage to the 
product may occur. 

- Wheel lock(s) are only intended to help prevent the stretcher from rolling while unattended and to aid in patient transfer. A wheel lock may 
not provide sufficient resistance on all surfaces or under loads. 

- Ensure that the restraints are not entangled in the base frame when raising and lowering the stretcher. 

- Do not store items under the stretcher mattress. Storing items under the mattress can interfere with the operation of the stretcher. 

- Do not steam clean or ultrasonically clean the unit. 

- Maximum water temperature should not exceed 80°C. 

- Allow stretcher to air dry. 

- Towel dry all casters and interface points. 

- Failure to comply with these instructions may invalidate any/all warranties. 

- Improper maintenance can cause injury or damage to the product. Maintain the stretcher as described in this manual. Use only Kartsana 
approved  parts  and maintenance procedures.  Using unapproved parts  and procedures  could cause unpredictable operation and/or injury 
and will void the product warranty 

- Failure to use authorized parts, lubricants, etc. could cause damage to the stretcher and will void the warranty of the product. 

NOTES:  

- Loose items or debris on the patient compartment floor can interfere with the operation of the safety hook and stretcher fastener. Keep the 
patient compartment floor clear 

-  This  manual  should  be  considered  a  permanent  part  of  the  stretcher  and  should  remain  with  the  product  even  if  the  stretcher  is 
subsequently sold. 

- Kartsana continually seeks advancements in product design and quality. Therefore, while this manual contains the most current product 
information available at the time of printing, there may be minor discrepancies between your stretcher and this manual 

- Kartsana recommends that, prior to installation, the certified mechanic plan the placement of the safety hook in the rear of the vehicle. 

 

 
 

Содержание TG-241 Series

Страница 1: ...all s BARCELONA TEL 93 714 49 24 Ventas kartsana com www kartsana kartsana com INSTRUCTION MANUAL COMPACT STRETCHER SERIE TG 241 Models TG 241 S TG 241 M TG 241 L Please read the instruction manual be...

Страница 2: ......

Страница 3: ...EAD 7 2 2 3 ADJUSTABLE LEG REST 8 2 2 4 SAFETY RAIL 8 2 2 5 INTRAVENOUS DRIP STAND 9 2 2 6 METHOD FOR FASTENING THE SAFETY BELTS ON THE PATIENT S HEAD AND FEET 10 2 2 7 METHOD FOR FASTENING THE SAFETY...

Страница 4: ...OPERATION AND HANDLING OF THE TG 241 SERIES 2 Rev 2 23 10 15...

Страница 5: ...harge of teaching all its employees how to use it correctly The product has a warranty of 24 months from the date of delivery to the end user The warranty will not cover the fault if that fault is due...

Страница 6: ...allow untrained assistants to assist in the operation of the stretcher Untrained technicians assistants can cause injury to the patient or themselves Grasping the stretcher improperly can cause injur...

Страница 7: ...er Do not store items under the stretcher mattress Storing items under the mattress can interfere with the operation of the stretcher Do not steam clean or ultrasonically clean the unit Maximum water...

Страница 8: ...ns in the event of an accident it is advisable to avoid sharp edges and projecting parts inside the ambulance paying special attention to the areas nearest to the stretcher Make sure that no damage is...

Страница 9: ...he top of the cuff and then pull it to lengthen the cuff as far as it will go To return the cuff to its original position press the top button again and push it as far as it will go in the original po...

Страница 10: ...button A to automatically lock the leg rest 2 2 4 Safety rail The safety rail has a red bar that locks the rail into place To lower the rail just press the bar as shown in the figure below To lock it...

Страница 11: ...Unscrewing the knob B we remove the IV drip stand to the vertical position perpendicular to the stretcher then we twist the knob again The length of said drip pole may be lengthened or shortened press...

Страница 12: ...s not fitted with the C openings 2 2 7 Method for fastening the safety belt on the patient s It is advisable for this belt to be attached to the stretcher to ensure the complete safety of the patients...

Страница 13: ...e stretcher belts Anchoring with a knot To dismantle the belts pass the belt through the slot in the buckle as shown in the following figure To assembly it just follow the same process but in reverse...

Страница 14: ...osition of the belts 2 2 8 1 1 Lateral belts The belts are positioned at the approximate distances shown in the figure below 2 2 8 1 2 Head belts The belts must be passed through the holes in the head...

Страница 15: ...of the rear leg of the stretcher Note If the cart is to be folded release the control just before the leg reaches the fully folded position To activate the intermediate positions release the control w...

Страница 16: ...unfolded position release the control so that when the leg reaches that position the click can be heard indicating the leg is locked and thereby ensuring it is fixed in the original unfolded position...

Страница 17: ...noeuvre activate the brakes on the front wheels and place them in the position shown on the adhesive before activating the red lever at the side The position is achieved by activating the intermediate...

Страница 18: ...he position shown on the adhesive before activating the red lever at the side It is achieved by activating the intermediate position lever red located on the right hand side of the stretcher This rele...

Страница 19: ...e rear wheels That special brake blocks both the longitudinal and the rotating movement of the stretcher 2 2 12 Lock Unlock wheels Rear wheels The green bolt is used to block or unblock the rotation o...

Страница 20: ...ntrol orange to fold it After activating the orange control part of the weight of the rear end of the stretcher must be supported and so it will be necessary to hold it firmly with both hands Once the...

Страница 21: ...ponsible for any anomaly or damage caused by using a cleaning product that could damage the surface of the rail materials To ensure the hygiene and proper conservation of the product components the ma...

Страница 22: ...OPERATION AND HANDLING OF THE TG 241 SERIES 20 Rev 2 23 10 15 5 EXPLODED VIEWS 5 1 TG 241 S...

Страница 23: ...OPERATION AND HANDLING OF THE TG 241 SERIES 21 Rev 2 23 10 15...

Страница 24: ...OPERATION AND HANDLING OF THE TG 241 SERIES 22 Rev 2 23 10 15...

Страница 25: ...OPERATION AND HANDLING OF THE TG 241 SERIES 23 Rev 2 23 10 15...

Страница 26: ...OPERATION AND HANDLING OF THE TG 241 SERIES 24 Rev 2 23 10 15 5 2 TG 241 M...

Страница 27: ...OPERATION AND HANDLING OF THE TG 241 SERIES 25 Rev 2 23 10 15...

Страница 28: ...OPERATION AND HANDLING OF THE TG 241 SERIES 26 Rev 2 23 10 15...

Страница 29: ...OPERATION AND HANDLING OF THE TG 241 SERIES 27 Rev 2 23 10 15...

Страница 30: ...OPERATION AND HANDLING OF THE TG 241 SERIES 28 Rev 2 23 10 15...

Страница 31: ...OPERATION AND HANDLING OF THE TG 241 SERIES 29 Rev 2 23 10 15 5 3 TG 241 L...

Страница 32: ...OPERATION AND HANDLING OF THE TG 241 SERIES 30 Rev 2 23 10 15...

Страница 33: ...OPERATION AND HANDLING OF THE TG 241 SERIES 31 Rev 2 23 10 15...

Страница 34: ...OPERATION AND HANDLING OF THE TG 241 SERIES 32 Rev 2 23 10 15...

Страница 35: ...in 50 xxxx xxx will be welding sets and it will be supplied like an inseparable set not at loose parts iii The pieces that his number reference starts in 52 xxxx xxx will be preassembly In case of re...

Страница 36: ...OPERATION AND HANDLING OF THE TG 241 SERIES 34 Rev 2 23 10 15...

Страница 37: ...OPERATION AND HANDLING OF THE TG 241 SERIES 35 Rev 2 23 10 15 Certified management system...

Отзывы: