G. SOLUTION TO POSSIBLE PROBLEMS
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
The display is blank and
the keys do not work.
Lack of power.
Check if the power supply cable is
connected.
Anomalies in the connection
between the display and the card.
Check if the display and the card
are properly connected.
The remote control
functions poorly.
Excessive distance from the stove. Get closer to the stove.
Remote control batteries
exhausted.
Check and substitute the batteries.
Unsuccessful lighting.
Excessive accumulation of pellets
in the grate.
Clean the grate.
The stove does not light
automatically.
The resistance does not reach its
temperature
Check the electric cables and
fuses.
Request the assistance center to
substitute the resistance, if
damaged.
Damaged or exhausted resistance. Substitute the resistance.
The pellets do not descend.
IMPORTANT: unplug the stove
before:
-
checking if the
pellets are
embedded in the
chute.
-
checking if screw is
blocked
-
check the door seal.
The stove is blocked.
Excessive use without cleaning the
grate.
Clean the grate.
Empty tank.
Load the pellets in the tank.
Screw without pellets.
Fill the tank and proceed as
indicated for the first lighting of the
stove.