Karel IPV20 Скачать руководство пользователя страница 3

 

IPV20 TECHNICAL REFERENCE & INSTALLATION GUIDE 

 

 

CUSTOMER INFORMATION 

1.  This  equipment  complies  with  Part  68  of  the  FCC  rules  and  the  requirements 
adopted  by  the  ACTA.  On  the  bottom  of  this  equipment  is  a  label  that  contains, 
among  other  information,  a  product  identifier  in  the  format  US:  UL7IS00BIPV20.  If 
requested, this number must be provided to the telephone company. 

2.  A  plug  and  jack  used  to  connect  this  equipment  to  the  premises  wiring  and 
telephone  network  must  comply  with  the  applicable  FCC  Part  68  rules  and 
requirements adopted by the ACTA. A compliant telephone cord and modular plug is 
provided  with  this  product.  It  is  designed  to  be  connected  to  a  compatible  modular 
jack that is also compliant. See installation instructions for details. 

3. If this equipment [Karel IP PBX IPV20] causes harm to the telephone network, the 
telephone  company  will  notify  you  in  advance  that  temporary  discontinuance  of 
service may be required. But if advance notice isn't practical, the telephone company 
will notify the customer as soon as possible. Also, you will be advised of your right to 
file a complaint with the FCC if you believe it is necessary. 

4. The telephone company may make changes in its facilities, equipment, operations 
or  procedures  that  could  affect  the  operation  of  the  equipment.  If  this  happens  the 
telephone  company  will  provide  advance  notice  in  order for  you to make  necessary 
modifications to maintain uninterrupted service. 

5.  If  trouble  is  experienced  with  this  equipment  [US:  UL7IS00BIPV20],  for  repair  or 
warranty information, Service can be facilitated through our office at:

 

U.S. Agent Company name: 
RONCO COMMUNICATIONS 
Address: 84 Grand Island Blvd 
Tonawanda, NY 14150 
Tel: 716-873-0760 
Fax: 716-879-8189

 

If  the  equipment is causing harm to the  telephone  network,  the  telephone  company 
may  request  that  you  disconnect  the  equipment  until  the  problem  is  resolved. 
Please check if KAREL has office or agent at USA to provide the repair or warranty 
services? If not then, you can just provide the office at Turkey or other country.

 

6. Connection to party line service is subject to state tariffs. Contact the state public 
utility  commission,  public  service  commission  or  corporation  commission  for 
information. 

7. If your home has specially wired alarm equipment connected to the telephone line, 
ensure  the  installation  of  this  [US:  UL7IS00BIPV20]  does  not  disable  your  alarm 
equipment.  If  you  have  questions  about  what  will  disable  alarm  equipment,  consult 
your telephone company or a qualified installer. 

8. If the telephone company requests information on what equipment is connected to 
their lines, inform them of: 

Содержание IPV20

Страница 1: ...IPV20 TECHNICAL REFERENCE INSTALLATION GUIDE 13 06 2012...

Страница 2: ...ction against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 3: ...uipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to...

Страница 4: ...a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that...

Страница 5: ...e opened by unauthorized persons in any way The cover of the exchange cabinet should always be kept closed All the ground connections on the covers must be fixed and checked before closing all the cov...

Страница 6: ...ing purposes Do not mount your system on mobile surfaces or near radiators or heat sources When you want to chance the location of the system consult authorized service When you need to carry your sys...

Страница 7: ...IPV20 EXCHANGE WALL INSTALLATION 5 MANAGEMENT OF THE IPV20 7 ADMINISTRATOR LOGIN 7 SOFTWARE STRUCTURE 8 THE IPV20 S OPERATING SYSTEM 8 IP EXTENSION AND LINE SERVICES 9 LICENSING FEATURES 11 NUMBERING...

Страница 8: ...tandard telecom equipment for those companies not yet ready for a standalone VoIP IP Telephony solution APPLICATIONS IP PBX FEATURES Auto Configuration Call Transfer IVR Interactive Voice Response Cal...

Страница 9: ...t WAN is in use 4 Green Light Indicates that the Internet LAN is in use 5 Red light An indicator for the FXO port A flashing red light indicates that the FXO port is not connected to a line A slow red...

Страница 10: ...call is ongoing on the FXS port Back LAN WAN Ethernet RJ45 1 8 Line Ports RJ11 9 16 Analog Telephone Ports RJ11 PARTS LIST ON DELIVERY IPV20 server unit Power source Internet cable Some telephone cabl...

Страница 11: ...nnect the Ethernet cable to the IPV20 s Ethernet port and connect the other end of the cable to a hub switch router LAN or WAN After connecting check the LED light a yellow light indicates that the co...

Страница 12: ...all and to mark the location of the holes The length of the power adapter cable must be considered when determining installation location Installation Template 2 Insert pegs inside the holes drilled o...

Страница 13: ...IPV20 TECHNICAL REFERENCE INSTALLATION GUIDE 6...

Страница 14: ...users various expectations All services can be programmed via the IPV20 s administration interface ComSer To do this double click on your PC s Internet browser icon to open a browser page and then ent...

Страница 15: ...oftware is saved as a compressed Flash image in the memory accompanying the CPU module When the PBX initially starts running it first loads the operating system into RAM memory from the compressed Fla...

Страница 16: ...ystem authorities IP EXTENSION AND LINE SERVICES One of the most important features of the IPV20 IP Telephone PBX is the provision of integrated support for IP Extensions and IP Lines A maximum of 40...

Страница 17: ...TUN support During IP connections to a VPN the IP extension applications act as if they were connected locally IP port routing is not required IP Lines can be selected so as to support the H323 and SI...

Страница 18: ...ed into the License Settings field on the ComSer interface NUMBERING PLAN When the installation of a IPV20 IP Telephone PBX of the required capacity is completed and the device is initially run it aut...

Страница 19: ...local computer via the ComSer web server Previously saved backups had to be restored to the system via the Database Converter However older configurations can still be used with these newer versions A...

Страница 20: ...IPV20 TECHNICAL REFERENCE INSTALLATION GUIDE 13 The following window of the ComSer programming interface appears...

Страница 21: ...umption 0 5W Max Power Consumption 20W 5 Dialing Dual Tone Multi Frequency Dialing DTMF 140 msec analog lines Digital info 6 Dialing Conversions IP RFC283 info DTMF DP RFC283 info elements 7 Speech Ch...

Страница 22: ...VDC 5 Wait Time between Two Consecutive Dials by the Auto dialer 175 5 msn 6 Cross Talk Attenuation Better than 70 dB 7 Maximum number of telephone sets per extension 2 Telephone Sets for analog exte...

Страница 23: ...ms to the G 168 standards 3 In band support Yes 4 Out of band RF2833 support INFO support 5 Telephone Standard SIP softphone IP phones 6 Web server support Yes 7 System Management Monitoring HTTP Teln...

Страница 24: ...one with Message Waiting 500 Hz 300 msec on 300 msec off 300 msec on 300 msec off 300 msec on 2000 msec off 6 Error Tone 500 Hz 300 msec on 300 msec off 300 msec on 300 msec off 300 msec on 300 msec o...

Страница 25: ...ernal Call 400 msec on 350 msec off 400 msec on 3500 msec off These values can be changed via the programming interface DTMF TONES High Frequency Group 7 dBm 1209 Hz 1336 Hz 1477 Hz Low 697 Hz 1 2 3 F...

Страница 26: ......